1 April 2010 in Advanced Materials Research
In this paper, rare-earth fluorides were used as sintering additives instead of rare-earth oxides, the influence of the type and the amount of the fluoride on the thermal conductivity, hardness and strength of Si3N4 ceramics was studied. Results show that the thermal conductivity of a sample sintered with CeF3 is nearly 10% higher than that of the sample sintered with Ce2O3, while the samples sintered with LaF3 increases further 15% as comparing with the samples sintered with CeF3. The strength of the samples changes reversely. These results express that the thermal conductivity of Si3N4 ceramics can be improved by using rare-earth fluoride additives instead of the oxides, and the type of rare-earth fluorides has a significant impact on the properties of Si3N4 ceramics.
1 November 2020 in Review of Scientific Instruments
A large liquid crystal glass substrate detection instrument usually uses the air flotation platform to support a glass substrate. The glass substrate will be deformed by air pressure on the air flotation platform, which will affect the accuracy of detection. In this paper, combined with the characteristics of the detection method of the detection instrument, an optimal detection scanning path with the minimum deflection variation range of the glass substrate is planned so as to minimize the influence of glass substrate deformation on the detection accuracy. In theory, the calculation model of the deflection variation ranges of different paths on the glass substrate is established, the numerical method is used to solve it, and finally, the optimal scanning path for the optical inspection is obtained. The experimental results verify the correctness of the model.
21 November 2019 in IEEE Access
n order to completely avoid the inter-axis coupling phenomenon in the triaxial force measurement process and improve the measurement accuracy, an air-supported force measurement method considering both supporting and force measurement is proposed. Based on this, a triaxial force measurement device without inter-axis coupling is constructed. The model of air-supported one-axis force measuring unit and air-supported triaxial force measurement device are established. An air-supported triaxial force measurement platform is developed to explore the measurement accuracy of the force in each axial direction and the Inter-axis coupling phenomenon. The experimental results show that the air-supported triaxial force measurement platform has the characteristics of "no Inter-axis coupling" and "high precision". The measurement error of the air-supported triaxial force measurement platform is 0.17% in the x-axis direction and 0.10% in the y-axis direction.