30 May 2018 in The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences
In dense stereo matching applications surface reflections may lead to incorrect measurements and blunders in the resulting point cloud. To overcome the problem of disturbing reflexions polarising filters can be mounted on the camera lens and light source. Reflections in the images can be suppressed by crossing the polarising direction of the filters leading to homogeneous illuminated images and better matching results. However, the filter may influence the camera’s orientation parameters as well as the measuring accuracy. To quantify these effects, a calibration and an accuracy analysis is conducted within a spatial test arrangement according to the German guideline VDI/VDE 2634.1 (2002) using a DSLR with and without polarising filter. In a second test, the interior orientation is analysed in more detail. The results do not show significant changes of the measuring accuracy in object space and only very small changes of the interior orientation (Δc ≤ 4 μm) with the polarising filter in use. Since in medical applications many tiny reflections are present and impede robust surface measurements, a prototypic trinocular endoscope is equipped with polarising technique. The interior and relative orientation is determined and analysed. The advantage of the polarising technique for medical image matching is shown in an experiment with a moistened pig kidney. The accuracy and completeness of the resulting point cloud can be improved clearly when using polarising filters. Furthermore, an accuracy analysis using a laser triangulation system is performed and the special reflection properties of metallic surfaces are presented.
12 August 2020 in The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences
In the last few years, photogrammetric methods for 3D surface reconstruction at close range have increased significantly in importance. On the one hand, this is due to the increased performance of the systems and on the other hand to the improved quality (accuracy, completeness) of the created point clouds. In order to verify the accuracy of various area probing methods, the German VDI guideline 2634 part 2 and 3 is applied. However, the high-precision test reference objects existing so far consist of diffuse textureless surfaces, so that passive methods, like image matching, cannot be compared with active methods (e.g. structured light systems). In order to make this possible, a certified textured dumbbell with an accuracy of better than 10 μm is presented in this paper, with the aim to examine the suitability of the textured dumbbell artefact for close-range photogrammetric 3D surface reconstruction. Furthermore, the accuracy level of a structured light system, Structure from Motion (SfM) and Multi-View Stereo Method (MVS) is verified and compared with each other.