Representative Publications

View All Publications
3 September 2019 in Medical Engineering & Physics
Verified
Journal Article
Open access
RCRobert J. Cooper
Robert J. Cooper
RWRuth K Wilcox
Ruth K Wilcox
AJAlison C. Jones
Alison C. Jones
The knee joint is a complex mechanical system, and computational modelling can provide vital information for the prediction of disease progression and of the potential for therapeutic interventions. This review provides an overview of the challenges involved in developing finite element models of the tibiofemoral joint, including the representation of appropriate geometry and material properties, loads and motions, and establishing pertinent outputs. The importance of validation for computational models in biomechanics has been highlighted by a number of papers, and finite element models of the tibiofemoral joint are a particular area in which validation can be challenging, due to the complex nature of the knee joint, its geometry and its constituent tissue properties. A variety of study designs have emerged to tackle these challenges, and these can be categorised into several different types. The role of validation, and the strategies adopted by these different study types, are discussed. Models representing trends and sensitivities often utilise generic representations of the knee and provide conclusions with relevance to general populations, usually without explicit validation. Models representing in vitro specimens or in vivo subjects can, to varying extents, be more explicitly validated, and their conclusions are more subject-specific. The potential for these approaches to examine the effects of patient variation is explored, which could lead to future applications in defining how treatments may be stratified for subgroups of patients.

1 May 2018 in Clinical Biomechanics
Verified
Journal Article
Open access
RCRobert J. Cooper
Robert J. Cooper
SWSophie Williams
Sophie Williams
MMMarlène Mengoni
Marlène Mengoni
AJAlison C. Jones
Alison C. Jones
Impingement resulting in soft tissue damage has been observed in hips with abnormal morphologies. Geometric parameterisation can be used to automatically generate a range of bone geometries for use in computational models, including femurs with cam deformity on the femoral neck. This study verified patient-specific parametric finite element models of 20 patients with cam deformity (10 female, 10 male) through comparison to their patient-specific segmentation-based equivalents. The parameterisation system was then used to generate further models with parametrically defined geometry to investigate morphological changes in both the femur and acetabulum and their effects on impingement. Similar findings were observed between segmentation-based and parametric models when assessing soft tissue strains under impingement conditions, resulting from high flexion and internal rotations. Parametric models with cam morphology demonstrated that clinically used alpha angles should not be relied on for estimating impingement severity since planar views do not capture the full three-dimensional geometry of the joint. Furthermore, the parametric approach allowed study of labral shape changes, indicating higher strains can result from bony overcoverage. The position of cams, as well as their size, can affect the level of soft tissue strain occurring in the hip. This highlights the importance of reporting the full details of three-dimensional geometry used when developing computational models of the hip joint and suggests that it could be beneficial to stratify the patient population when considering treatment options, since certain morphologies may be at greater risk of elevated soft tissue strain.

1 September 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
RCRobert J. Cooper
Robert J. Cooper
ALAiqin Liu
Aiqin Liu
GDGavin A. Day
Gavin A. Day
VWVithanage N. Wijayathunga
Vithanage N. Wijayathunga
LJLouise M. Jennings
Louise M. Jennings
AJAlison C. Jones
Alison C. Jones
The successful development of cartilage repair treatments for the knee requires understanding of the biomechanical environment within the joint. Computational finite element models play an important role in non-invasively understanding knee mechanics, but it is important to compare model findings to experimental data. The purpose of this study was to develop a methodology for generating subject-specific finite element models of porcine tibiofemoral joints that was robust and valid over multiple different constraint scenarios. Computational model predictions of two knees were compared to experimental studies on corresponding specimens loaded under several different constraint scenarios using a custom designed experimental rig, with variations made to the femoral flexion angle and level of tibial freedom. For both in vitro specimens, changing the femoral flexion angle had a marked effect on the contact distribution observed experimentally. With the tibia fixed, the majority of the contact region shifted to the medial plateau as flexion was increased. This did not occur when the tibia was free to displace and rotate in response to applied load. These trends in contact distribution across the medial and lateral plateaus were replicated in the computational models. In an additional model with the meniscus removed, contact pressures were elevated by a similar magnitude to the increase seen when the meniscus was removed experimentally. Overall, the models were able to capture specimen-specific trends in contact distribution under a variety of different loads, providing the potential to investigate subject-specific outcomes for knee interventions.

5 April 2017 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
RCRobert J. Cooper
Robert J. Cooper
MMMarlène Mengoni
Marlène Mengoni
DGDawn Groves
Dawn Groves
SWSophie Williams
Sophie Williams
MBMarcus J.K. Bankes
Marcus J.K. Bankes
AJAlison Jones
Alison Jones
Abnormal bony morphology is a factor implicated in hip joint soft tissue damage and an increased lifetime risk of osteoarthritis. Standard 2‐dimensional radiographic measurements for diagnosis of hip deformities, such as cam deformities on the femoral neck, do not capture the full joint geometry and are not indicative of symptomatic damage.In this study, a 3‐dimensional geometric parameterisation system was developed to capture key variations in the femur and acetabulum of subjects with clinically diagnosed cam deformity. The parameterisation was performed for computed tomography scans of 20 patients (10 female and 10 male). Novel quantitative measures of cam deformity were taken and used to assess differences in morphological deformities between males and females.The parametric surfaces matched the more detailed, segmented hip bone geometry with low fitting error. The quantitative severity measures captured both the size and the position of cams and distinguished between cam and control femurs. The precision of the measures was sufficient to identify differences between subjects that could not be seen with the sole use of 2‐dimensional imaging. In particular, cams were found to be more superiorly located in males than in females.As well as providing a means to distinguish between subjects more clearly, the new geometric hip parameterisation facilitates the flexible and rapid generation of a range of realistic hip geometries including cams. When combined with material property models, these stratified cam shapes can be used for further assessment of the effect of the geometric variation under impingement conditions.