Jaryl Ng

Jaryl Ng

Auto-generated profile, based on publicly available information

Jaryl Ng

National Heart Centre Singapore, Singapore

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2016 in International Journal of Cardiology
Verified
Journal Article
Open access
JNJaryl Ng
Jaryl Ng
NFNicolas Foin
Nicolas Foin
HAHui Ying Ang
Hui Ying Ang
JFJiang Ming Fam
Jiang Ming Fam
SSSayan Sen
Sayan Sen
PWPhilip Wong
Philip Wong
Previously, we examined the difference in stent designs across different sizes for six widely used Drug Eluting Stents (DESs). Although stent post-dilatation to larger diameter is commonly done, typically in the setting of long tapering segment or left-main PCI, there is an increasing recognition that information with regard to the different stent model designs has a critical impact on overexpansion results. This study aims to provide an update on stent model designs for contemporary DES platforms as well as test overexpansion results under with oversized post-dilatation. We studied 6 different contemporary commercially available DES platforms: Synergy, Xience Xpedition, Ultimaster, Orsiro, Resolute Onyx and Biomatrix Alpha. We investigated for each platform the difference in stent designs across different sizes and results obtained after post-expansion with larger balloon sizes. The stents were deployed at nominal diameter and subsequently over expanded using increasingly large post dilatation balloon sizes (4.0, 5.0 and 6.0mm at 14ATM). Light microscopy was used to measure the changes in stent geometry and lumen diameter after over-expansion. For each respective DES platform, the MLD observed after overexpansion of the largest stent size available with a 6.0mm balloon was 5.7mm for Synergy, 5.6mm for Xience, 5.2mm for Orsiro, 5.8mm for Ultimaster, 5.5mm for 4mm Onyx (5.9mm for the 5mm XL size) and 5.8mm for BioMatrix Chroma. This update presents valuable novel insights that may be helpful for careful selection of stent size for contemporary DES based on model designs. Such information is especially critical in left main bifurcation stenosis treatment where overexpansion to larger oversized diameter may be required to ensure full stent apposition.

1 January 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DTDaniel Wee Yee Toong
Daniel Wee Yee Toong
JNJaryl Chen Koon Ng
Jaryl Chen Koon Ng
Fangsen CuiFangsen Cui
Fangsen Cui
HLHwa Liang Leo
Hwa Liang Leo
LZLiang Zhong
Liang Zhong
HAHui Ying Ang
Hui Ying Ang

21 January 2022 in Nanomedicine
Verified
Journal Article
Closed access
JNJaryl Chen Koon Ng
Jaryl Chen Koon Ng
DTDaniel Wee Yee Toong
Daniel Wee Yee Toong
VOValerie Ow
Valerie Ow
SCSu Yin Chaw
Su Yin Chaw
HTHanwei Toh
Hanwei Toh
HAHui Ying Ang
Hui Ying Ang
Drug-delivery systems in cardiovascular applications regularly include the use of drug-eluting stents and drug-coated balloons to ensure sufficient drug transfer and efficacy in the treatment of ca... Graphical abstract

1 November 2016 in International Journal of Cardiology
Verified
Journal Article
Closed access
NFNicolas Foin
Nicolas Foin
JNJaryl Ng
Jaryl Ng
PWPhilip Wong
Philip Wong
CMCarlo Di Mario
Carlo Di Mario

20 November 2022 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
JNJaryl Chen Koon Ng
Jaryl Chen Koon Ng
HAHuiying Ang
Huiying Ang
LZLiang Zhong
Liang Zhong
DHDiaa Hakim
Diaa Hakim
KMKostas Marmagkiolis
Kostas Marmagkiolis
MLMassoud A. Leesar
Massoud A. Leesar

1 April 2021 in JACC
Verified
Journal Article
Closed access
JNJaryl Ng
Jaryl Ng
Paradies ValeriaParadies Valeria
Paradies Valeria
SLShengjie Lu
Shengjie Lu
GVGeorgios J Vlachojannis
Georgios J Vlachojannis
Hwa Liang LeoHwa Liang Leo
Hwa Liang Leo
HAHui Ying Ang
Hui Ying Ang