Eda Nur Saruhan

Eda Nur Saruhan

Auto-generated profile, based on publicly available information

Eda Nur Saruhan

Koc University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ADAli Anil Demircali
Ali Anil Demircali
RVRahmetullah Varol
Rahmetullah Varol
GAGizem Aydemir
Gizem Aydemir
ESEda Nur Saruhan
Eda Nur Saruhan
KEKadir Erkan
Kadir Erkan
HUHuseyin Uvet
Huseyin Uvet
This article presents an untethered magnetic manipulation technique for controlling a microrobot position under high rate laminar flows up to 4.5 mL/min. An increase in flow rate exponentially increases the drag force on the microrobot and negatively impacts its positioning accuracy. Increasing the longitudinal force generated by the microrobot’s driving apparatus helps in overcoming the disruptive effects of the fluid flow and increases longitudinal motion stability. To this end, we propose a magnetic configuration with two ring-shaped magnets, one above and the other below the microfluidic channel. This configuration causes the magnetic field lines emanating from the ring-shaped magnets to converge on both sides of the microrobot. Thus, the magnetic trapping forces that hold the microrobot in position are increased. To the best of our knowledge, no prior study exists on investigating the longitudinal motion for high flow velocities ( $>$ 5 mm/s). Investigating the longitudinal forces (along the x -axis) that affect a magnetically driven microrobot is a novel research topic that has many potential application areas, such as cell research, micromanipulation, and lab-on-a-chip systems. The microrobot’s dynamical motion is modeled as a second-order system, and using this model as a guideline, we demonstrate the ability of a microrobot in a square-shaped microfluidic channel ( $900$ $\times 900\,{\mu \text{m}}^{2}$ ) to follow a linear trajectory with a relative velocity up to 132.6 ${\text{mm/s}}$ . A straight and longitudinal trajectory of 4000 $\mu \text{m}$ has been successfully followed in the same and opposite directions to the flow for different flow rates (1–4.5 mL/min) and different robot speeds (10–50 mm/s).

22 July 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
ESEda Nur Saruhan
Eda Nur Saruhan
HOHakancan Ozturk
Hakancan Ozturk
DKDemet Kul
Demet Kul
BSBortecine Sevgin
Bortecine Sevgin
MCMerve Nur Coban
Merve Nur Coban
KPKerem Pekkan
Kerem Pekkan
Fibrous proteins, such as elastin and collagen, are crucial for the structural integrity of the cardiovascular system. For thin tissue-engineered heart valves and surgical patches, the two-dimensional mapping of fiber orientation is well-established. However, for three-dimensional (3D) thick tissue samples, e.g., the embryonic whole heart, robust 3D fiber analysis tools are not available. This information is essential for computational vascular modeling and tissue microstructure characterization. Therefore, this study employs machine learning (ML) and deep learning (DL) techniques to analyze the 3D cardiovascular fiber structures in thick samples of porcine pericardium and embryonic whole hearts. It is hypothesized that ML/DL-based fiber orientation analysis will outperform traditional Fourier transform and directional filter methods by offering higher spatial accuracy and reduced dependency on manual preprocessing. We trained our ML/DL models on both synthetic and real-world cardiovascular datasets obtained from confocal imaging. The evaluation used a mixed dataset of 1200 samples and a porcine/bovine dataset of 400 samples. Support vector regression (SVR) demonstrated the highest accuracy, achieving a normalized mean absolute error (nMAE) of 5.0% on the mixed dataset and 13.0% on the biological dataset. Among DL models, convolutional neural network (CNN) and residual network-50 (ResNet50) had an nMAE of 12.0% and 11.0% on the mixed dataset and 23.0% and 22.0% on the biological dataset, respectively. Attention mechanisms improved performance further, with the channel attention ResNet50 achieving an nMAE of 5.8% on the mixed dataset and 21.0% on the biological dataset. These findings highlight the potential of ML and DL techniques in improving 3D fiber orientation detection, enabling detailed cardiovascular microstructural assessment.

28 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
ESEda Nur Saruhan
Eda Nur Saruhan
AUAzmat Ullah
Azmat Ullah
MSMelis Serdar
Melis Serdar
KPKerem Pekkan
Kerem Pekkan
Background and Objective: Quantifying blood flow in embryonic vasculature from optical coherence tomography (OCT) images is hindered by severe speckle noise, low contrast and the absence of ground-truth motion labels. Particle image velocimetry and generic deep learning optical flow models are sensitive to speckle, suffer from domain mismatch and depend on dataset-specific preprocessing. This study aimed to develop a weakly supervised deep learning framework for dense flow estimation in noisy embryonic OCT image sequences.,Methods: We propose OCT-RAFT, which couples a pretrained Recurrent All-Pairs Field Transforms (RAFT) backbone with a lightweight U-Net refinement module. Because annotated flow data are unavailable, the model is trained with Farneback-derived optical flow as a weak supervisory signal and a center-weighted spatial loss mask that emphasizes high-motion vascular regions; the loss combines masked L1 flow, relative angle and spatial smoothness terms. The model was trained on seven OCT sequences from seven chick embryos using a single standardized preprocessing pipeline. It was evaluated on an in vitro microfluidic phantom with a known flow rate and on 15 independently acquired in vivo chick embryos at Hamburger–Hamilton stages 18, 20 and 22 (n = 5 per stage), and compared with particle image velocimetry, Farneback dense optical flow, SPyNet, pretrained RAFT and fine-tuned RAFT. Results were analyzed descriptively using means, standard deviations and 95% confidence intervals.,Results: In vitro, OCT-RAFT velocities agreed with continuity-based theoretical predictions within 8.1% at the channel inlet and 8.3% at the widest section, with inter-run coefficients of variation of 2.1% and 6.0% for the inlet and channel-averaged velocities. In vivo, OCT-RAFT yielded mean velocity magnitudes of 0.11 ± 0.06, 0.19 ± 0.11 and 0.48 ± 0.15 mm/s at stages 18, 20 and 22, compared with 0.32 ± 0.30, 0.81 ± 0.44 and 3.30 ± 1.70 mm/s for particle image velocimetry, and produced spatially coherent flow fields with fewer background artifacts than the baseline methods.,Conclusions: OCT-RAFT provides a weakly supervised framework for quantitative blood flow analysis in embryonic OCT imaging without dataset-specific tuning, and its design may transfer to other speckle-rich biomedical imaging modalities.