Bogdan Vysotskyi

Bogdan Vysotskyi

Auto-generated profile, based on publicly available information

Bogdan Vysotskyi

Univ. Grenoble Alpes, F-38000 Grenoble, France and CEA, LETI, MINATEC Campus, F-38054 Grenoble, France

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2023 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
BVBogdan Vysotskyi
Bogdan Vysotskyi
JCJose-Francisco Ambia Campos
Jose-Francisco Ambia Campos
ELElie Lefeuvre
Elie Lefeuvre
ABAlexis Brenes
Alexis Brenes

4 May 2018 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
BVBogdan Vysotskyi
Bogdan Vysotskyi
DADenis Aubry
Denis Aubry
PGPhilippe Gaucher
Philippe Gaucher
XRXavier Le Roux
Xavier Le Roux
FPFabien Parrain
Fabien Parrain
ELElie Lefeuvre
Elie Lefeuvre
This paper presents an experimental proof-of-concept of an innovative design of electrostatic vibration energy harvester based on a double bistable curved beam whose mechanical behaviour is significantly modified by additional linear springs. The basic analytical model for a curved beam with dynamical and quasi static behaviour is introduced and validated by finite element modelling. It is shown that the static force offset due to the gravity field can provide an important increase in the sensitivity to external acceleration. The device is fabricated using silicon on glass technology without the need of a wafer bonding technique. Energy harvesting experiments are performed with various orientations of the device relative to the gravity field direction. The electrical power output is derived from the output voltage measured across a storage capacitor. It is shown that the maximum power output of the energy harvester reaches 10 µ W under 50 Hz, 10 m s −2 sine excitation, and is sensible at accelerations with amplitudes less than 1 g (down to 3 m s −2 ) and operating at a very low frequency range (5–100 Hz) with an overall device size of 1 cm × 1.5 cm × 200 µ m.

13 December 2017 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
BVBogdan Vysotskyi
Bogdan Vysotskyi
FPFabien Parrain
Fabien Parrain
DADenis Aubry
Denis Aubry
PGPhilippe Gaucher
Philippe Gaucher
XRXavier Le Roux
Xavier Le Roux
ELElie Lefeuvre
Elie Lefeuvre
The purpose of this paper is to introduce a novel technique to engineer in a precise way the structural nonlinearity in MEMS springs. To perform the adjustment of structural nonlinearity, the idea of using a sine-shaped beam following the combination of the natural bending modes of a straight one is explored to create a multimodal-shaped spring. The basic analytical model of multimodal beam bending is introduced and validated with finite element modeling. Proposed multimodal springs are fabricated by deep reactive ion etching on silicon on insulator wafer and their force-displacement characteristics are extracted using a force probe, with the resulting curves being close to the ones predicted by the theoretical calculations. The presented spring allows the engineering of structural nonlinearity by varying the amplitudes of the different modes used as initial shape. Thus, a straightforward method to create any type of structural nonlinearity starting from fully bistable up to the linear case, without the need to combine springs of several types, reducing the complexity of the targeted systems and their footprint. The proposed methodology was used to successfully design a suspension spring that exhibits flat force-displacement region with the aim to increase the bandwidth of vibrational energy harvesters.

1 October 2016 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
BVBogdan Vysotskyi
Bogdan Vysotskyi
FPFabien Parrain
Fabien Parrain
ELElie Lefeuvre
Elie Lefeuvre
XLXavier Leroux
Xavier Leroux
DADenis Aubry
Denis Aubry
PGPhilippe Gaucher
Philippe Gaucher
This work is dedicated for the study of energy harvesters implemented in form of microelectromechanical systems (MEMS) used to harvest ambient vibrations for powering standalone electronic devices. The previewed application is to power a leadless pacemaker with mechanical energy of the heartbeat, which requires the amount of power typically more than 1μW. The target of the presented article is to combine the effect of bistability and nonlinear coupling by electrostatic effect in order to achieve the high value of bandwidth at the low frequency under the low accelerations. Such system is expected to bring high power density performance. This study is performed mostly by numerical simulation.

9 August 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TFThomas Fortin
Thomas Fortin
BVBogdan Vysotskyi
Bogdan Vysotskyi
MDMartial Defoort
Martial Defoort
ARAdrien Reynaud
Adrien Reynaud
SLSzu-Hsueh Lai
Szu-Hsueh Lai
CMChristophe Masselon
Christophe Masselon
Due to their physical properties, nanomechanical sensors (NEMS) can achieve mass measurements in the mega- to gigadalton range, which is hardly obtained with conventional mass-spectrometers. However, NEMS signals are subject to noise, causing a loss of mass resolution and thus emphasizing the need of noise control. We propose a denoising model that relies on a total variation formulation, which deals with different noise models (particularly colored noise) affecting NEMS. The model also takes into account the physics of NEMS, such as the non-linear coupling between signals of individual NEMS. The performance of the proposed model is tested on simulated data which parameters are chosen similar to true experimental conditions. The obtained results confirm the interest of our model with a mass-resolution increase over 20% compared to methods used in literature.

3 April 2026
Verified
Thesis
Closed access
BVBogdan Vysotskyi
Bogdan Vysotskyi
Récupérateur d'énergie vibratoire MEMS électrostatique à large bande pour applications biomédicales: Ce travail de recherche porte sur le développement et la mise au point d'un récupérateur d'énergie vibratoire MEMS à transduction capacitive dédié aux applications biomédicales et plus particulièrement aux stimulateurs cardiaques sans sondes autonomes. Cette application impose une miniaturisation poussée (volume inférieur à 1 cm³), une puissance de sortie dans la gamme allant de 1 à 10 µW et une compatibilité vis-à-vis des systèmes d'Imagerie à Résonance Magnétique (IRM). Ces contraintes ainsi que l'effet de la gravité ont été pris en compte sur tout le flot de conception afin d'obtenir un dispositif innovant en technologie MEMS silicium capable de fournir une puissance de sortie suffisante quelle que soit son orientation une fois implanté. Afin de convertir efficacement les battements cardiaques ayant un spectre étendu (de 1 à 50 Hz) pour une amplitude d'accélération faible (inférieure à 1 g), le système emploie des bras de suspension ayant une raideur non-linéaire ce qui permet d'étendre notablement la bande passante effective du système. Cette non-linéarité est ici induite de manière originale en faisant en sorte que la forme initiale des bras de suspension soit une combinaison linéaire des modes de déformée propre d'une poutre doublement encastrée. Un soin particulier a été apporté afin de modéliser ceci dans le but de prédire la réponse mécanique du système quels que soient les stimuli imposés. Afin de réaliser les différents dispositifs de test, une technologie MEMS de type SOG (Silicon-On-Glass) a été développée. Cette technologie permet d'obtenir des structures en silicium monocristallin avec un fort rapport d'aspect tout en limitant le budget thermique et se montre donc compatible avec une éventuelle industrialisation. Ceci a été prouvé via la réalisation de multiples véhicules de test qui se sont montrés totalement fonctionnels. Ainsi la pertinence des modèles théoriques permettant de prédire le comportement non-linéaire des ressorts employés a été prouvée de manière expérimentale. De même, les récupérateurs d'énergie réalisés ont été testés en régime harmonique mais également via des stimuli cardiaques et ont montré une large bande passante avec une puissance de sortie équivalente à celle donnée dans l'état de l'art et ce, quelle que soit leur orientation par rapport à la gravité.