Andrew J. Reader

Andrew J. Reader

Auto-generated profile, based on publicly available information

Andrew J. Reader

King’s College London

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FLF Lamare
F Lamare
MCM J Ledesma Carbayo
M J Ledesma Carbayo
TCT Cresson
T Cresson
GKGeorge Kontaxakis
George Kontaxakis
ASAndres Santos
Andres Santos
DVD Visvikis
D Visvikis
Respiratory motion in emission tomography leads to reduced image quality. Developed correction methodology has been concentrating on the use of respiratory synchronized acquisitions leading to gated frames. Such frames, however, are of low signal-to-noise ratio as a result of containing reduced statistics. In this work, we describe the implementation of an elastic transformation within a list-mode-based reconstruction for the correction of respiratory motion over the thorax, allowing the use of all data available throughout a respiratory motion average acquisition. The developed algorithm was evaluated using datasets of the NCAT phantom generated at different points throughout the respiratory cycle. List-mode-data-based PET-simulated frames were subsequently produced by combining the NCAT datasets with Monte Carlo simulation. A non-rigid registration algorithm based on B-spline basis functions was employed to derive transformation parameters accounting for the respiratory motion using the NCAT dynamic CT images. The displacement matrices derived were subsequently applied during the image reconstruction of the original emission list mode data. Two different implementations for the incorporation of the elastic transformations within the one-pass list mode EM (OPL-EM) algorithm were developed and evaluated. The corrected images were compared with those produced using an affine transformation of list mode data prior to reconstruction, as well as with uncorrected respiratory motion average images. Results demonstrate that although both correction techniques considered lead to significant improvements in accounting for respiratory motion artefacts in the lung fields, the elastic-transformation-based correction leads to a more uniform improvement across the lungs for different lesion sizes and locations.

29 May 2008 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
FSFlorent C. Sureau
Florent C. Sureau
ARAndrew J. Reader
Andrew J. Reader
CCClaude Comtat
Claude Comtat
CLClaire Leroy
Claire Leroy
MRMaria-Joao Ribeiro
Maria-Joao Ribeiro
RTRégine Trébossen
Régine Trébossen
Brain PET in small structures is challenged by low resolution inducing bias in the activity measurements. Improved spatial resolution may be obtained by using dedicated tomographs and more comprehensive modeling of the acquisition system during reconstruction. In this study, we assess the impact of resolution modeling (RM) during reconstruction on image quality and on the estimates of biologic parameters in a clinical study performed on a high-resolution research tomograph. Methods: An accelerated list-mode ordinary Poisson ordered-subset expectation maximization (OP-OSEM) algorithm, including sinogram-based corrections and an experimental stationary model of resolution, has been designed. Experimental phantom studies are used to assess contrast and noise characteristics of the reconstructed images. The binding potential of a selective tracer of the dopamine transporter is also assessed in anatomic volumes of interest in a 5-patient study. Results: In the phantom experiment, a slower convergence and a higher contrast recovery are observed for RM-OP-OSEM than for OP-OSEM for the same level of statistical noise. RM-OP-OSEM yields contrast recovery levels that could not be reached without RM as well as better visual recovery of the smallest spheres and better delineation of the structures in the reconstructed images. Statistical noise has lower variance at the voxel level with RM than without at matched resolution. In a uniform activity region, RM induces higher positive and lower negative correlations with neighboring voxels, leading to lower spatial variance. Clinical images reconstructed with RM demonstrate better delineation of cortical and subcortical structures in both time-averaged and parametric images. The binding potential in the striatum is also increased, a result similar to the one observed in the phantom study. Conclusion: In high-resolution PET, RM during reconstruction improves quantitative accuracy by reducing the partial-volume effects.

6 August 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
ARAndrew J. Reader
Andrew J. Reader
GCGuillaume Corda
Guillaume Corda
AMAbolfazl Mehranian
Abolfazl Mehranian
CCCasper da Costa-Luis
Casper da Costa-Luis
SESam Ellis
Sam Ellis
JSJulia A. Schnabel
Julia A. Schnabel
This article reviews the use of a sub-discipline of artificial intelligence (AI), deep learning, for the reconstruction of images in positron emission tomography (PET). Deep learning can be used either directly or as a component of conventional reconstruction, in order to reconstruct images from noisy PET data. The review starts with an overview of conventional PET image reconstruction and then covers the principles of general linear and convolution-based mappings from data to images, and proceeds to consider non-linearities, as used in convolutional neural networks (CNNs). Direct deep-learning methodology is then reviewed in the context of PET reconstruction. Direct methods learn the imaging physics and statistics from scratch, not relying on a priori knowledge of these models of the data. In contrast, model-based or physics-informed deep-learning uses existing advances in PET image reconstruction, replacing conventional components with deep-learning data-driven alternatives, such as for the regularisation. These methods use trusted models of the imaging physics and noise distribution, while relying on training data examples to learn deep mappings for regularisation and resolution recovery. After reviewing the main examples of these approaches in the literature, the review finishes with a brief look ahead to future directions.

14 October 2003 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
ARA.J. Reader
A.J. Reader
PJP.J. Julyan
P.J. Julyan
HWH. Williams
H. Williams
DHD.L. Hastings
D.L. Hastings
JZJ. Zweit
J. Zweit
Methodology for PET system modeling using image-space techniques in the expectation maximization (EM) algorithm is presented. The approach, applicable to both list-mode data and projection data, is of particular significance to EM algorithm implementations which otherwise only use basic system models (such as those which calculate the system matrix elements on the fly). A basic version of the proposed technique can be implemented using image-space convolution, in order to include resolution effects into the system matrix, so that the EM algorithm gradually recovers the modeled resolution with each update. The improved system modeling (achieved by inclusion of two convolutions per iteration) results in both enhanced resolution and lower noise, and there is often no need for regularization-other than to limit the number of iterations. Tests have been performed with simulated list-mode data and also with measured projection data from a GE Advance PET scanner, for both [/sup 18/F]-FDG and [/sup 124/I]-NaI. The method demonstrates improved image quality in all cases when compared to the conventional FBP and EM methods presently used for clinical data (which do not include resolution modeling). The benefits of this approach for /sup 124/I (which has a low positron yield and a large positron range, usually resulting in noisier and poorer resolution images) are particularly noticeable.

23 June 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
AMAbolfazl Mehranian
Abolfazl Mehranian
ARAndrew J. Reader
Andrew J. Reader
We propose a forward-backward splitting algorithm to integrate deep learning into maximum-a-posteriori (MAP) positron emission tomography (PET) image reconstruction. The MAP reconstruction is split into regularization, expectation-maximization (EM), and a weighted fusion. For regularization, the use of either a Bowsher prior (using Markov-random fields) or a residual learning unit (using convolutional-neural networks) were considered. For the latter, our proposed forward-backward splitting EM (FBSEM), accelerated with ordered subsets (OS), was unrolled into a recurrent-neural network in which network parameters (including regularization strength) are shared across all states and learned during PET reconstruction. Our network was trained and evaluated using PET-only (FBSEM-p) and PET-MR (FBSEM-pm) datasets for low-dose simulations and short-duration in-vivo brain imaging. It was compared to OSEM, Bowsher MAPEM, and a post-reconstruction U-Net denoising trained on the same PET-only (Unet-p) or PET-MR (Unet-pm) datasets. For simulations, FBSEM-p(m) and Unet-p(m) nets achieved a comparable performance, on average, 14.4% and 13.4% normalized root-mean square error (NRMSE), respectively; and both outperformed OSEM and MAPEM methods (with 20.7% and 17.7% NRMSE, respectively). For in-vivo datasets, FBSEM-p(m), Unet-p(m), MAPEM, and OSEM methods achieved average root-sum-of-squared errors of 3.9%, 5.7%, 5.9%, and 7.8% in different brain regions, respectively. In conclusion, the studied U-Net denoising method achieved a comparable performance to a representative implementation of the FBSEM net.

1 June 2011 in NeuroImage
Verified
Journal Article
Closed access
CFChristian la Fougère
Christian la Fougère
SGSarah Grant
Sarah Grant
AKAlexey Kostikov
Alexey Kostikov
RSRalf Schirrmacher
Ralf Schirrmacher
PGPaul Gravel
Paul Gravel
ATAlexander Thiel
Alexander Thiel