Sam Ellis

Sam Ellis

Auto-generated profile, based on publicly available information

Sam Ellis

School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2020 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
ARAndrew J. Reader
Andrew J. Reader
GCGuillaume Corda
Guillaume Corda
AMAbolfazl Mehranian
Abolfazl Mehranian
CCCasper da Costa-Luis
Casper da Costa-Luis
SESam Ellis
Sam Ellis
JSJulia A. Schnabel
Julia A. Schnabel
This article reviews the use of a sub-discipline of artificial intelligence (AI), deep learning, for the reconstruction of images in positron emission tomography (PET). Deep learning can be used either directly or as a component of conventional reconstruction, in order to reconstruct images from noisy PET data. The review starts with an overview of conventional PET image reconstruction and then covers the principles of general linear and convolution-based mappings from data to images, and proceeds to consider non-linearities, as used in convolutional neural networks (CNNs). Direct deep-learning methodology is then reviewed in the context of PET reconstruction. Direct methods learn the imaging physics and statistics from scratch, not relying on a priori knowledge of these models of the data. In contrast, model-based or physics-informed deep-learning uses existing advances in PET image reconstruction, replacing conventional components with deep-learning data-driven alternatives, such as for the regularisation. These methods use trusted models of the imaging physics and noise distribution, while relying on training data examples to learn deep mappings for regularisation and resolution recovery. After reviewing the main examples of these approaches in the literature, the review finishes with a brief look ahead to future directions.

1 April 2020 in Computer Physics Communications
Verified
Journal Article
Closed access
EOEvgueni Ovtchinnikov
Evgueni Ovtchinnikov
RBRichard Brown
Richard Brown
CKChristoph Kolbitsch
Christoph Kolbitsch
EPEdoardo Pasca
Edoardo Pasca
CCCasper da Costa-Luis
Casper da Costa-Luis
KTKris Thielemans
Kris Thielemans

6 June 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
JBJames Bland
James Bland
MBMartin Belzunce
Martin Belzunce
SESam Ellis
Sam Ellis
CMColm J. McGinnity
Colm J. McGinnity
AHAlexander Hammers
Alexander Hammers
ARAndrew J. Reader
Andrew J. Reader
Positron emission tomography (PET) is a highly sensitive functional and molecular imaging modality which can measure picomolar concentrations of an injected radionuclide. However, the physical sensitivity of PET is limited, and reducing the injected dose leads to low count data and noisy reconstructed images. A highly effective way of reducing noise is to reparameterize the reconstruction in terms of MR-derived spatial basis functions. Spatial basis functions derived using the kernel method have demonstrated excellent noise reduction properties and maintain shared PET-MR detailed structures. However, as previously shown in the literature, the MR-guided kernel method may lead to excessive smoothing of structures that are only present in the PET data. This paper makes two main contributions in order to address this problem: first, we exploit the potential of the MR-guided kernel method to form more spatially compact basis functions which are able to preserve PET-unique structures, and second, we consider reconstruction at the native MR resolution. The former contribution notably improves the recovery of structures which are unique to the PET data. These adaptations of the kernel method were compared to the conventional implementation of the MR-guided kernel method and also to maximum likelihood expectation maximization, in terms of ability to recover PET unique structures for both simulated and real data. The spatially compact kernel method showed clear visual and quantitative improvements in the reconstruction of the PET unique structures, relative to the conventional kernel method for all sizes of PET unique structures investigated, whilst maintaining to a large extent the impressive noise mitigating and detail preserving properties of the conventional MR-guided kernel method. We therefore conclude that a spatially compact parameterization of the MR-guided kernel method, should be the preferred implementation strategy in order to obviate unnecessary losses in PET-unique details.

28 May 2021 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
CMCamila Munoz
Camila Munoz
SESam Ellis
Sam Ellis
SNStephan G. Nekolla
Stephan G. Nekolla
KKKarl P. Kunze
Karl P. Kunze
TVTeresa Vitadello
Teresa Vitadello
CPClaudia Prieto
Claudia Prieto
Simultaneous PET-MR imaging has shown potential for the comprehensive assessment of myocardial health from a single examination. Furthermore, MR-derived respiratory motion information has been shown to improve PET image quality by incorporating this information into the PET image reconstruction. Separately, MR-based anatomically guided PET image reconstruction has been shown to perform effective denoising, but this has been so far demonstrated mainly in brain imaging. To date the combined benefits of motion compensation and anatomical guidance have not been demonstrated for myocardial PET-MR imaging. This work addresses this by proposing a single cardiac PET-MR image reconstruction framework which fully utilises MR-derived information to allow both motion compensation and anatomical guidance within the reconstruction. Methods: Fifteen patients underwent a 18F-FDG cardiac PET-MR scan with a previously introduced acquisition framework. The MR data processing and image reconstruction pipeline produces respiratory motion fields and a high-resolution respiratory motion-corrected MR image with good tissue contrast. This MR-derived information was then included in a respiratory motion-corrected, cardiac-gated, anatomically guided image reconstruction of the simultaneously acquired PET data. Reconstructions were evaluated by measuring myocardial contrast and noise and compared to images from several comparative intermediate methods using the components of the proposed framework separately. Results: Including respiratory motion correction, cardiac gating, and anatomical guidance significantly increased contrast. In particular, myocardium-to-blood pool contrast increased by 143% on average (p<0.0001) compared to conventional uncorrected, non-guided PET images. Furthermore, anatomical guidance significantly reduced image noise compared to non-guided image reconstruction by 16.1% (p<0.0001). Conclusion: The proposed framework for MR-derived motion compensation and anatomical guidance of cardiac PET data was shown to significantly improve image quality compared to alternative reconstruction methods. Each component of the reconstruction pipeline was shown to have a positive impact on the final image quality. These improvements have the potential to improve clinical interpretability and diagnosis based on cardiac PET-MR images.

14 January 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
ARAndrew J. Reader
Andrew J. Reader
SESam Ellis
Sam Ellis
In emission tomography, iterative image reconstruction from noisy measured data usually results in noisy images, and so regularisation is often used to compensate for noise. However, in practice, an appropriate, automatic and precise specification of the strength of regularisation for image reconstruction from a given noisy measured dataset remains unresolved. Existing approaches are either empirical approximations with no guarantee of generalisation, or else are computationally intensive cross-validation methods requiring full reconstructions for a limited set of preselected regularisation strengths. In contrast, we propose a novel methodology embedded within iterative image reconstruction, using one or more bootstrapped replicates of the measured data for precise optimisation of the regularisation. The approach uses a conventional unregularised iterative update of a current image estimate from the noisy measured data, and then also uses the bootstrap replicate to obtain a bootstrap update of the current image estimate. The method then seeks the regularisation hyperparameters which, when applied to the bootstrap update of the image, lead to a best fit of the regularised bootstrap update to the conventional measured data update. This corresponds to estimating the degree of regularisation needed in order to map the noisy update to a model of the mean of an ensemble of noisy updates. For a given regularised objective function (e.g. penalised likelihood), no hyperparameter selection or tuning is required. The method is demonstrated for positron emission tomography (PET) data at different noise levels, and delivers near-optimal reconstructions (in terms of reconstruction error) without any knowledge of the ground truth, nor any form of training data.

1 July 2024 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
SESam Ellis
Sam Ellis
SGSandra Gomes
Sandra Gomes
MTMatthew Trumble
Matthew Trumble
MHMark D. Halling-Brown
Mark D. Halling-Brown
KYKenneth C. Young
Kenneth C. Young
LWLucy M. Warren
Lucy M. Warren
"Just Accepted" papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review before it is published in its final version. Please note that during production of the final copyedited article, errors may be discovered which could affect the content. Purpose To develop an artificial intelligence (AI) deep learning tool capable of predicting future breast cancer risk from a current negative screening mammographic examination and to evaluate the model on data from the UK National Health Service Breast Screening Program. Materials and Methods The OPTIMAM Mammography Imaging Database contains screening data, including mammograms and information on interval cancers, for > 300,000 women who attended screening at three different sites in the UK from 2012 onward. Cancer-free screening examinations from women aged 50-70 years were obtained and classified as risk-positive or risk-negative based on the occurrence of cancer within 3 years of the original examination. Examinations with confirmed cancer and images containing implants were excluded. From the resulting 5264 risk-positive and 191488 risk-negative examinations, training (n = 89285) validation (n = 2106) and test (n = 39351) datasets were produced for model development and evaluation. The AI model was trained to predict future cancer occurrence based on screening mammograms and patient age. Performance was evaluated on the test dataset using the area under the receiver operating characteristic curve (AUC) and compared across subpopulations to assess potential biases. Interpretability of the model was explored, including with saliency maps. Results On the hold-out test set, the AI model achieved an overall AUC of 0.70 (95% CI: 0.69, 0.72). There was no evidence of a difference in performance across the three sites, between patient ethnicities or across age-groups Visualization of saliency maps and sample images provided insights into the mammographic features associated with AI-predicted cancer risk. Conclusion The developed AI tool showed good performance on a multisite, UK-specific dataset. ©RSNA, 2024.