Jodie N. Haigh

Jodie N. Haigh

Auto-generated profile, based on publicly available information

Jodie N. Haigh

Department of Functional Materials in Medicine and Dentistry and Bavarian Polymer Institute, University Hospital of Würzburg, Pleicherwall 2, 97070, Würzburg, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2018 in Small
Verified
Journal Article
Open access
PDF file
AHAndrei Hrynevich
Andrei Hrynevich
BEBilge Ş. Elçi
Bilge Ş. Elçi
JHJodie N. Haigh
Jodie N. Haigh
RMRebecca McMaster
Rebecca McMaster
AYAlmoatazbellah Youssef
Almoatazbellah Youssef
PDPaul D. Dalton
Paul D. Dalton
The electrohydrodynamic stabilization of direct‐written fluid jets is explored to design and manufacture tissue engineering scaffolds based on their desired fiber dimensions. It is demonstrated that melt electrowriting can fabricate a full spectrum of various fibers with discrete diameters (2–50 µm) using a single nozzle. This change in fiber diameter is digitally controlled by combining the mass flow rate to the nozzle with collector speed variations without changing the applied voltage. The greatest spectrum of fiber diameters was achieved by the simultaneous alteration of those parameters during printing. The highest placement accuracy could be achieved when maintaining the collector speed slightly above the critical translation speed. This permits the fabrication of medical‐grade poly(ε‐caprolactone) into complex multimodal and multiphasic scaffolds, using a single nozzle in a single print. This ability to control fiber diameter during printing opens new design opportunities for accurate scaffold fabrication for biomedical applications.

1 January 2016 in BioNanoMaterials
Verified
Journal Article
Open access
PDF file
GHGernot Hochleitner
Gernot Hochleitner
AYAlmoatazbellah Youssef
Almoatazbellah Youssef
AHAndrei Hrynevich
Andrei Hrynevich
JHJodie N. Haigh
Jodie N. Haigh
JTJungst Tomasz
Jungst Tomasz
PDPaul D. Dalton
Paul D. Dalton
Additive manufacturing with electrohydrodynamic direct writing is a promising approach for the production of polymeric microscale objects. In this study we investigate the stability of one such process, melt electrospinning writing, to maintain accurate placement of the deposited fibre throughout the entire print. The influence of acceleration voltage and feeding pressure on the deposited poly(ε-caprolactone) fibre homogeneity is described, and how this affects the variable lag of the jet drawn by the collector movement. Three classes of diameter instabilities were observed that led to poor printing quality: (1) temporary pulsing, (2) continuous pulsing, and (3) regular long bead defects. No breakup of the electrified jet was observed for any of the experiments. A simple approach is presented for the melt electrospinning user to evaluate fibre writing integrity, and adjust the processing parameters accordingly to achieve reproducible and constant diameter fibres.

1 August 2017 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
JHJodie N. Haigh
Jodie N. Haigh
TDTim R. Dargaville
Tim R. Dargaville
PDPaul D. Dalton
Paul D. Dalton

14 December 2017 in Small
Verified
Journal Article
Open access
PDF file
MRMylène de Ruijter
Mylène de Ruijter
AHAndrei Hrynevich
Andrei Hrynevich
JHJodie N. Haigh
Jodie N. Haigh
GHGernot Hochleitner
Gernot Hochleitner
Miguel CastilhoMiguel Castilho
Miguel Castilho
PDPaul D. Dalton
Paul D. Dalton
One challenge in biofabrication is to fabricate a matrix that is soft enough to elicit optimal cell behavior while possessing the strength required to withstand the mechanical load that the matrix is subjected to once implanted in the body. Here, melt electrowriting (MEW) is used to direct‐write poly(ε‐caprolactone) fibers “out‐of‐plane” by design. These out‐of‐plane fibers are specifically intended to stabilize an existing structure and subsequently improve the shear modulus of hydrogel–fiber composites. The stabilizing fibers (diameter = 13.3 ± 0.3 µm) are sinusoidally direct‐written over an existing MEW wall‐like structure (330 µm height). The printed constructs are embedded in different hydrogels (5, 10, and 15 wt% polyacrylamide; 65% poly(2‐hydroxyethyl methacrylate) (pHEMA)) and a frequency sweep test (0.05–500 rad s−1, 0.01% strain, n = 5) is performed to measure the complex shear modulus. For the rheological measurements, stabilizing fibers are deposited with a radial‐architecture prior to embedding to correspond to the direction of the stabilizing fibers with the loading of the rheometer. Stabilizing fibers increase the complex shear modulus irrespective of the percentage of gel or crosslinking density. The capacity of MEW to produce well‐defined out‐of‐plane fibers and the ability to increase the shear properties of fiber‐reinforced hydrogel composites are highlighted.

16 October 2015 in Macromolecular Rapid Communications
Verified
Journal Article
Closed access
PDF file
JHJodie N. Haigh
Jodie N. Haigh
YCYa‐Mi Chuang
Ya‐Mi Chuang
Brooke FarrugiaBrooke Farrugia
Brooke Farrugia
Richard HoogenboomRichard Hoogenboom
Richard Hoogenboom
PDPaul D. Dalton
Paul D. Dalton
TDTim R. Dargaville
Tim R. Dargaville