Ultrasound detection can promptly identify partial discharge (PD) faults inside power transformer by using fiber-optic Fabry-Perot (F-P) array sensors. This paper presents a new design scheme for a wideband acousto-optic direct-coupled F-P sensor. Indirect-coupled F-P sensors have a narrow, highly sensitive response region, and direct-coupled F-P sensors have a wide band response from 1 to 200 kHz. We constructed a PD database by simulating different PD signals in oil tank. We proposed learnable KAN kernel to replace traditional CNN kernel and introduced KAN as a replacement for the ReLU function. Furthermore, we conducted pattern recognition research with a convolutional depth of only 6 layers. The test accuracy on oil tank dataset reached 98.7% for KAN Convolution + ReLU and 99.5% for KAN Convolution + KAN. The validation accuracy achieved by inputting PD signals measured from a real 220 kV power transformer into the two models was 97.5% and 98.75%, respectively.
7 May 2021 in IEEE Transactions on Instrumentation and Measurement
Detecting insulation performance through testing the Raman spectroscopy of transformer oil is noninvasive and shows great promise in on-site diagnosis. The information, stored in spectra, that may reflect aging states of insulation aims to be effectively unfolded and provides decision support as well. In this article, a transformation method based on intrinsic product arithmetic is used to transform the 1-D Raman spectral data into 2-D image data. With the help of CNN based on the dimensionality expanding method, diagnosis of oil-paper insulation with different aging states based on the Raman spectroscopy was realized. The network-based oil-paper insulation aging diagnosis model has an accuracy of 95% in ten aging categories of 60 test samples and 100% in four aging categories. The result shows the trained CNN was able to identify the differences of transformer oil samples at each aging stage through visualized Raman spectral image. This method provides a more accurate determination method for diagnosing oil-immersed transformers' aging conditions; it also develops an available method for a more detailed evaluation of insulation aging levels.
17 August 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Recognizing the patterns of partial discharge (PD) is the key to assess the hazard level of PD. This article proposes an oil-immersed transformer PD pattern recognition method based on a multifrequency fiber-optic Fabry–Perot (F–P) ultrasound sensing array and deep learning (DL). Three F–P ultrasonic probes with different resonance bands were used to form a sensing array for collecting ultrasonic signals excited by PD. Five types of PD models were prepared, including metal tip (MT) discharge in oil, PD in the air cavity (AC), and surface discharge (SD) on the pressboard, in addition to SD after pressboard blocking or after pressboard plus transformer winding blocking, to study the influence of ultrasonic attenuation on recognition accuracy. The collected PD ultrasound signal time-frequency matrix was obtained using adaptive optimal-kernel time–frequency representation to reinforce the differences in PD patterns. Then, based on the features of the PD ultrasonic signals, the signal time and frequency band for analysis were determined. The intercepted time–frequency matrix of the signals from the three F–P probes was formed into a (3, 300, 375) tensor. A modified ResNet-18 net was used for PD pattern recognition, which achieved a 98% recognition accuracy. The probabilities given by the softmax function were used to study the confidence of the model’s predictions of signals belonging to known and unknown types.
1 December 2022 in IET Generation, Transmission & Distribution
Arc discharge in the power transformer can bring enormous economic losses and safety risks. The transformer protection system for arc discharge faults is still not ideal. The physical characteristics of the whole process from partial discharge defects transition to arc faults are not fully recognized, mainly because it is difficult to establish and sense the relevant characteristic parameters. This paper built a research platform for studying the transition process from partial discharge to early arc discharge based on fibre‐optic ultrasonic, temperature, pressure sensors with traditional electrical voltage and current sensors. Five discharge models are designed and the changing pattern of multiple parameters in the transition process of different models is studied. The experiment results show that the amplitude and frequency of acoustic waves drop significantly after the arc breakdown. Ultrasonic and high‐frequency current sensing in the early warning of arc fault each has its own limitations. The pressure caused by the arc is not only related to the arc energy but also related to the discharge types. The overall oil temperature change after the early arc discharge is small and hard to detect. This work highlights the promise of using fibre‐optic sensors for physical process research within a harsh electromagnetic environment.
6 May 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Timely identification of the aging stage of the transformer can effectively ensure the safe operation of the transformer and prevent the aging fault of the transformer. This work proposes the aging diagnosis of transformer using the Raman spectroscopic recurrence plot combined with learning vector quantization (LVQ) neural network. Oil-paper insulation samples at different aging stages are obtained by accelerated thermal aging tests. Acquisition of Raman spectra of insulating oil is from 800 to 3000 cm −1 and converts to the Raman spectroscopic recurrence plot. The gray-level cooccurrence matrix (GLCM) is used to extract the characteristic information of the Raman spectroscopic recurrence plot. The optimal number of neurons in competitive layer of LVQ neural network is determined by the experimental method. A transformer aging diagnosis model based on the Raman spectroscopic recurrence plot is established. The results show that the diagnostic accuracy of the proposed diagnostic model reached 95%. The Raman spectroscopic recurrence plot has more abundant aging “fingerprint” characteristic information and the proposed diagnostic method shows potential for monitoring oil-paper insulation.
The vibration spectroscopy (Raman and infrared) of widely concerned molecules in sulfur corrosion phenomenon (Dibenzyl Disulfide, Dibenzyl Sulphide, and Bibenzyl) is detailedly analyzed based on density functional theory and experimental measurement. The dominant conformations of these molecules are determined according to Boltzmann distribution in relative Gibbs free energy. Additionally, noncovalent interaction analysis is conducted to indicate intramolecular interaction. Vibration normal mode is assigned based on potential energy distribution, which comprehensively reveals the molecular vibrational behaviors. Conformations weighted spectra are obtained and compared with experimentally measured spectra. We found that experimental spectra are in good agreement with the theoretical spectra in B3LYP-D3(BJ)/6-311G** level with a frequency correction factor. Furthermore, the divergence among these molecules is discussed. The vibrational behavior of the methylene group in the molecule shows a trend with the presence of the sulfur atom.