Xiaomin Duan

Xiaomin Duan

Auto-generated profile, based on publicly available information

Xiaomin Duan

Department of Radiology, Beijing Children's Hospital Capital Medical University, National Center for Children's Health, Nan Lishi Road 56#, West District, Beijing 100045, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2017 in La radiologia medica
Verified
Journal Article
Closed access
PDF file
JSJihang Sun
Jihang Sun
QZQifeng Zhang
Qifeng Zhang
XDXiaomin Duan
Xiaomin Duan
CZChengyue Zhang
Chengyue Zhang
PWPengpeng Wang
Pengpeng Wang
YPYun Peng
Yun Peng

1 January 2021 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
XWXichen Wang
Xichen Wang
Huiliang CaoHuiliang Cao
Huiliang Cao
XDXiaomin Duan
Xiaomin Duan
To solve the problem of micro‐electro‐mechanical system (MEMS) gyroscope noise, this paper presents a variational mode decomposition (VMD) method based on crow search algorithm. First, the signal was decomposed by variational mode decomposition for optimization of crow search algorithm (CSA‐VMD) method. The parameters required by the VMD method (penalty parameter α and decomposition number K) are given by the crow search algorithm, and then the signal is decomposed into the superposition of multiple subsignals, called intrinsic mode functions (IMFs). The sample entropy (SE) corresponding to each IMF is then obtained. By calculating the sample entropy, the noise signal can be divided into pure noise part, mixing part, and temperature drift part. Second, Savitzky–Golay smoothing denoising (SG) is used to filter the mixed noise signal to eliminate the influence of noise. Third, for the filtering of the drift part, the least square support vector machine optimized by the crow search algorithm (CSA‐LSSVM) was used to filter, so as to reduce the effect of temperature drift. Finally, the processed signal is reconstructed to achieve the goal of denoising. Through the results, it can be found that the optimized VMD and LSSVM using CSA algorithm can achieve more effective denoising. After using the method proposed in this paper, the angular random walk value is 1.1175 ∗ 10−4°/h/√Hz, and the bias stability is 0.0017°/h. Compared with the original signal, the two signals are optimized by 98.1% and 98.2%, respectively. It can be seen from the experimental results that the proposed CSA‐VMD method, SG method, and CSA‐LSSVM method can effectively eliminate noise effects.

11 June 2022 in Radiology Case Reports
Verified
Journal Article
Open access
LZLili Zang
Lili Zang
TYTong Yu
Tong Yu
XDXiaomin Duan
Xiaomin Duan
Xiaoyan ZhangXiaoyan Zhang
Xiaoyan Zhang
JZJiexin Zhang
Jiexin Zhang
JWJie Wang
Jie Wang
Neonatal obstetric brachial plexus palsy is common in newborns with fetal macrosomia, especially those who are delivered vaginally with shoulder dystocia or breech delivery. The anatomical structure of brachial plexus in newborns is thin, and it is neither collinear nor coplanar in space; The location, the type and degree of neonatal brachial plexus injury need to be comprehensively judged by clinical history, neurological and imaging examination. Conventional MR imaging is not sufficient to diagnose brachial plexus injury. In this case report, we describe the clinical and imaging data of a newborn with brachial plexus injury diagnosed by the fat-suppressed T2-weighted sequence and MR myelography and confirmed by surgery. In addition, we review the related literature in an attempt to provide a better understanding of the principles and characteristics of neonatal brachial plexus injury diagnosed by magnetic resonance neurography.