5 May 2020 in Journal of Earthquake Engineering
This paper investigates the potentials of inter-story isolation systems (IIS) for retrofitting irregular masonry buildings by means of an isolated vertical addition realised on the roof of the existing structure. By assuming a case study, a wide parametric analysis is firstly carried out on lumped-masses model for identifying the dynamic properties of the isolated superstructure that minimizes the global seismic response. Hence, a 3D FE model is adopted for the detailed design and analysis of the IIS structure, with different solutions, in order to regularize the global seismic response of the IIS complex. Finally, some general design criteria are suggested.
1 April 2019 in Composites Part B: Engineering
1 April 2010 in Journal of Cultural Heritage
1 January 2011 in International Journal of Materials and Structural Integrity
In this paper, a simplified theoretical model (named 'the arched strut'), useful for the evaluation of the structural behaviour of masonry spandrels subjected to shear, is proposed. It has been defined on the basis of the results of both numerical and experimental analyses performed on reduced scale specimens. The numerical analysis has been carried out in order to obtain confirmation of the collapse mechanisms observed during the experiments and information which cannot be directly obtained from testing and is difficult to obtain theoretically too, such as the extension of the effective area at the edges of the panel and the value of the horizontal component of the force acting in the strut. By means of the proposed model, theoretical expressions corresponding to the different observed failure mechanisms (toe-crushing and tension cracking) have been formulated. Finally, both experimental and theoretical findings have been compared with the Italian code requirements.
3 December 2019 in Fracture and Structural Integrity
Unreinforced masonry is the most diffused construction material in the major part of historical centers in Europe. In a building subjected to earthquake forces the contribution of in-plane shear resistance of the masonry walls is a determinant factor for the stability of the whole structure. In particular, the masonry piers are the structural elements subjected to the combination of normal and shear forces. In general, ductile tools to model the in plane behaviour of masonry are always welcome in order to evaluate the capacity of walls subjected to vertical and horizontal actions. In this framework, two no-tension approaches to model the behaviour of masonry walls loaded with in-plane forces, involving a minimum energy procedure, are presented. Both the procedures allow the representation of the stress maps in the panel in case of monotonic increase of shear load. The results of the numerical analyses are compared and discussed.