Diana Faiella

Dr. Diana Faiella

University of Naples 'Federico II', Italy
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2022 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
MAMario Argenziano
Mario Argenziano
DFDiana Faiella
Diana Faiella
ACA.R. Carotenuto
A.R. Carotenuto
Elena MeleElena Mele
Elena Mele
MFMassimiliano Fraldi
Massimiliano Fraldi

15 May 2019 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
DFDiana Faiella
Diana Faiella
EMElena Mele
Elena Mele

5 May 2020 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
DFDiana Faiella
Diana Faiella
BCBruno Calderoni
Bruno Calderoni
Elena MeleElena Mele
Elena Mele
This paper investigates the potentials of inter-story isolation systems (IIS) for retrofitting irregular masonry buildings by means of an isolated vertical addition realised on the roof of the existing structure. By assuming a case study, a wide parametric analysis is firstly carried out on lumped-masses model for identifying the dynamic properties of the isolated superstructure that minimizes the global seismic response. Hence, a 3D FE model is adopted for the detailed design and analysis of the IIS structure, with different solutions, in order to regularize the global seismic response of the IIS complex. Finally, some general design criteria are suggested.

15 February 2024 in Buildings
Verified
Journal Article
Open access
PDF file
FAFabrizio Ascione
Fabrizio Ascione
FEFrancesco Esposito
Francesco Esposito
GIGiacomo Iovane
Giacomo Iovane
DFDiana Faiella
Diana Faiella
Beatrice FaggianoBeatrice Faggiano
Beatrice Faggiano
Elena MeleElena Mele
Elena Mele
The paper focuses on tall timber buildings. The major aim of this paper is to identify the most sustainable and efficient structural system to increase the height of timber buildings, also considering steel–timber hybrid structures. First of all, a brief review of tall buildings’ evolution is presented to understand why tall timber buildings are considered nowadays and which are the most adopted structural solutions. Then, the case study of the tallest timber building in the world is selected and utilized as an archetype. Once the model has been validated, seven alternative structural systems are considered by varying the horizontal load resisting system and preserving the same member cross-sections as the reference building. The variants are tested and compared in terms of material consumption, vibration characteristics and lateral load response. Using the best structural system, the height of the building is increased, pushing the structures beyond the current limits and identifying the most efficient option. The idea is to preserve the column cross-sections and balance the increase in gravity loads due to the additional floors by replacing the concrete floors with timber counterparts. With the same structural system, equivalent steel–timber hybrid solutions are finally tested and compared in terms of sustainability to timber-only counterparts and to the original project. The results of analyses show that the use of steel elements combined with timber can lead to optimized and sustainable structural solutions.

1 March 2021 in Buildings
Verified
Journal Article
Open access
PDF file
FCFrancesco Cascone
Francesco Cascone
DFDiana Faiella
Diana Faiella
VTValentina Tomei
Valentina Tomei
Elena MeleElena Mele
Elena Mele
An innovative generative design strategy, based on shape grammar, is proposed for the minimum-weight design of diagrid tall buildings. By considering the building as a three-dimensional vertical cantilever beam with a tubular section under horizontal load, it is evident that bending and shear stiffness demands vary along the width and elevation of the building. Further, while the structural design of tall buildings is usually governed by stiffness, the predominant design criterion for diagrids could be the local strength demand, especially for low slenderness values, thanks to the inherent rigidity of the triangular pattern. Starting from these considerations, in this paper, a generative design strategy is proposed, able to find diagrid patterns that accommodate the differentiated stiffness demand along width/elevation and satisfy the predominant design criterion, stiffness or strength. The design strategy is applied to tall building models characterised by different slenderness values. The comparison to diagrid patterns analysed in previous literature works in terms of structural weight and performance parameters highlights the effectiveness of the design strategy and the efficiency of the generated patterns.

31 December 2023 in Journal of Building Engineering
Verified
Journal Article
Open access
DDDiana D’aGostino
Diana D’aGostino
DFDiana Faiella
Diana Faiella
EFEnrico Febbraro
Enrico Febbraro
EMElena Mele
Elena Mele
FMFrancesco Minichiello
Francesco Minichiello
JTJessica Trimarco
Jessica Trimarco