Yuly Bay

Yuly Bay

Auto-generated profile, based on publicly available information

Yuly Bay

School of Energy & Power Engineering, National Research Tomsk Polytechnic University, Tomsk 634050, Russia

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
Alisher AskarovAlisher Askarov
Alisher Askarov
PRPavel Radko
Pavel Radko
YBYuly Bay
Yuly Bay
IGIvan Gusarov
Ivan Gusarov
VKVagiz Kabirov
Vagiz Kabirov
ASA A Suvorov
A A Suvorov
A key direction of the development of modern power systems is the application of a continuously increasing number of grid-forming power converters to provide various system services. One of the possible strategies for the implementation of grid-forming control is a control algorithm based on a virtual synchronous generator (VSG). However, at present, the problem of VSG operation under abnormal conditions associated with an increase in output current remains unsolved. Existing current saturation algorithms (CSAs) lead to the degradation of grid-forming properties during overcurrent limiting or reduce the possible range of current output. In this regard, this paper proposes to use the structure of modified current-controlled VSG (CC-VSG) instead of traditional voltage-controlled VSG. A current vector amplitude limiter is used to limit the output current in the CC-VSG structure. At the same time, the angle of the current reference vector continues to be regulated based on the emerging operating conditions due to the voltage feedback in the used VSG equations. The presented simulation results have shown that it was possible to achieve a wide operating range for the current phase from 0° to 180° in comparison with a traditional VSG algorithm. At the same time, the properties of the grid-forming inverter, such as power synchronization without phase-locked loop controller, voltage, and frequency control, are preserved. In addition, in order to avoid saturation of the voltage controller, it is proposed to use a simple algorithm of blocking and switching the reference signal from the setpoint to the current voltage level. Due to this structure, it was possible to prevent saturation of integrators in the control loops and to provide a guaranteed exit from the limiting mode. The results of adding this structure showed a five-second reduction in the overvoltage that occurs when it is absent. A comparison with conditional integration also showed that it prevented lock-up in the limiting mode. The results of experimental verification of the developed prototype of the inverter with CC-VSG control and CSA are also given, including a comparison with the serial model of the hybrid inverter. The results obtained showed that the developed algorithm excludes both the dead time and the load current loss when the external grid is disconnected. In addition, there is no tripping during overload, unlike a hybrid inverter.

10 December 2024 in Mathematics
Verified
Journal Article
Open access
PDF file
Alisher AskarovAlisher Askarov
Alisher Askarov
YBYuly Bay
Yuly Bay
RURuslan Ufa
Ruslan Ufa
PRPavel Radko
Pavel Radko
Pavel Vladimirovich IlyushinPavel Vladimirovich Ilyushin
Pavel Vladimirovich Ilyushin
ASA A Suvorov
A A Suvorov
In the last decade, a rather new phenomenon related to subsynchronous oscillations (SSO) in a wide frequency range has emerged in modern power grids with power converters. The consequences of these oscillations can be severe system accidents, which have already occurred in various power systems. Taking into account the importance of studying such oscillations for effective mitigation and the existing gaps in understanding the mechanisms of SSO occurrence due to different combinations of used controllers in the inverter control system, as well as the grid parameters, a frequency analysis of simplified grid inverter models is performed. As a result, five different mechanisms of SSO occurrence, the affecting factors and the level of inverter model detail required for the adequate study of SSO are justified. The developed detailed state–space model allowed for verifying the obtained results, as well as identifying an additional sixth mechanism of SSO occurrence. The common condition for the occurrence of all the identified SSO mechanisms is a weak grid with a short-circuit ratio of less than two. The results of control hardware-in-the-loop testing confirmed the conclusions drawn. As a result, a classification of SSO occurrence mechanisms was formed, reflecting their causes and distinctive features.

7 December 2021 in PRZEGLĄD ELEKTROTECHNICZNY
Verified
Journal Article
Closed access
YBYuly Bay
Yuly Bay
NRNikolay Ruban
Nikolay Ruban
MAMikhail Andreev
Mikhail Andreev
AGAlexandr Gusev
Alexandr Gusev
The penetration of renewable energy sources (RES) into the electricity supply is gaining popularity all over the world, including countries that have large oil and gas reserves, since only the development of alternative energy will help avoid regression and take a green path development, reducing the damage to the environment. According to estimates of the International Energy Agency (IEA), the capacity of RES units built in China in 2016 was 34 GW, and Australia is one of the world leaders in the photovoltaic power plants installation, the share of which in the Australian electricity production exceeds 3%. It should be noted, that the final power generation capacity and stability are stochastic (probabilistic) in nature. Unlike the classical type generator, the output RES characteristics depend on the geographical features of the installation area, the season, and prevailing winds. Risks associated with inaccurate knowledge of the cumulative distribution function (CDF) describing these sources, as well as environmental uncertainties, are the reasons why it is more difficult for distribution network operators (DNO) to take RES into account in the power balance calculations. The wind speed CDF clarification can provide significant assistance in predicting the RES power production

1 January 2019 in AIP Conference Proceedings
Verified
Conference Paper
Open access
YBYuly Bay
Yuly Bay
YMYana Malkova
Yana Malkova
ABAnna Buran
Anna Buran