Chris Joseph Kovacs

Chris Joseph Kovacs

Auto-generated profile, based on publicly available information

Chris Joseph Kovacs

Scintillating Solutions LLC, Columbus, OH, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2018 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
DZDanlu Zhang
Danlu Zhang
CKChris Joseph Kovacs
Chris Joseph Kovacs
JRJ Rochester
J Rochester
MMMilan Majoros
Milan Majoros
FWFang Wan
Fang Wan
MMMichael Martens
Michael Martens
A react-and-wind MgB 2 coil segment for a conduction-cooled magnetic resonance imaging (MRI) machine has been fabricated and tested. The coil was developed as part of a collaborative effort on a conduction-cooled, MgB 2 -based, whole-body MRI image guided radiation therapy device. This study focuses on the fabrication, winding, instrumentation, cooling, and initial critical current ( I c ) testing of this near-full-size MgB 2 segment coil. The coil was 0.9 m in diameter; the winding pack, 44.0 mm wide × 50.6 mm high, used 1.7 km of an 18 filament MRI-style conductor with Nb chemical barriers, Cu interfilamentary matrices, and an outer monel sheath. The conductor was insulated and reacted before winding onto a stainless steel former. The coil was instrumented with Cernox and E-type thermocouple temperature sensors, strain sensors, and voltage taps. The conduction-cooled coil was mounted in a cryostat capable of accepting coils of up to 0.9 m in diameter and 0.5 m in height. Critical current measurements were performed as a function of temperature during a controlled heating of the coil. The operational target was I = 200 A at 13 K. The full magnet was designed to produce 0.75 T in the imaging area (at I = 200 A), with a maximum field of 1.93 T in the winding. The single segment coil measured here exceeded this operation specification, with an I c of 280 A at 15 K and a maximum field 1.93 T in the winding. The coil was modeled using a finite element method, and a load line plot showed that 100% of short sample was reached at 21.5 K and above. These measurements demonstrate the viability of conduction-cooled MgB 2 background coils as replacements for liquid helium cooled NbTi background coils in future MRI devices.

5 February 2024 in Superconductor Science and Technology
Verified
Journal Article
Open access
JFJoshua Feldman
Joshua Feldman
WSWolfgang Stautner
Wolfgang Stautner
CKChristopher Kovacs
Christopher Kovacs
NMNenad Miljkovic
Nenad Miljkovic
KHKiruba S Haran
Kiruba S Haran
Construction of high-temperature superconducting magnets typically involves impregnation of a coil in a liquid medium, such as epoxy, which is then solidified. This impregnation provides mechanical integrity to the magnet and facilitates heat transfer. The choice of material used for impregnation requires careful consideration of the material properties and the performance requirements in order to ensure optimal magnet operation. This paper offers a comprehensive educational resource on this topic, reviewing the literature available on materials for magnet impregnation. A detailed explanation of considerations for selecting an impregnation material are presented, along with a review of several types of materials and their characteristics as reported in the literature. The materials are compared, and their suitability to different applications is discussed. Topics for future research are suggested.

21 April 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SSSaeid Saeidabadi
Saeid Saeidabadi
LPLeila Parsa
Leila Parsa
KCKeith Corzine
Keith Corzine
CKChristopher Kovacs
Christopher Kovacs
THTimothy J. Haugan
Timothy J. Haugan
The increasing demand for high-power density motors in electric transport industries opens a new research opportunity to develop motor topologies with less weight and high efficiency. In particular, all-electric aircraft applications require very high power density motors. This paper shows the design of a new 1 MW 20-pole/15-slot double rotor flux switching machine with high-temperature superconducting field coils and thermal management system. The proposed motor features an air-core stator. Aluminum Litz wire is used for the armature conductors, and the YBCO- high-temperature superconducting material is used for the field coils. The armature winding and field coils operate at 95K and 65K, respectively. The active part power density including rotors, armature windings and field coils obtained with the proposed design is 29.3kW/kg. The specific power density of proposed motor considering mechanical, support structure and TMS is about 18.5 kW/kg. The efficiency can be higher than 98.7% which satisfies the requirement of electric aviation.

1 June 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
CKChris J. Kovacs
Chris J. Kovacs
MSMike D. Sumption
Mike D. Sumption
MMMilan Majoros
Milan Majoros
ECEdward W. Collings
Edward W. Collings

11 September 2024 in IEEE Access
Verified
Journal Article
Open access
SSSaeid Saeidabadi
Saeid Saeidabadi
LPLeila Parsa
Leila Parsa
KCKeith A. Corzine
Keith A. Corzine
CKChris Kovacs
Chris Kovacs
THTimothy Haugan
Timothy Haugan
In this study, a 1 MW double-rotor flux switching machine is designed for high-power density electric motors in all-electric aircraft. The motor features an air core stator that accommodates armature windings and field coils. Armature conductors utilize aluminum Litz wire at T=20K, while YBCO superconducting tapes are employed for the field coils operating at T=20 K. The inner and outer rotors are constructed with laminated Hiperco 50. Most notably, superconducting magnetic shields are positioned between the two rotor teeth to minimize leakage flux and guide magnetizing flux on a pre-determined path. This new motor is shown to have widely superior power density and efficiency. The motor design is evaluated across different pole/slot combinations, revealing that higher pole numbers increase power density. Specifically, a 20-pole/15-slot double rotor flux switching motor with a shield achieves a power density exceeding 100 kW/kg, with efficiency reaching up to 99.5%. This was twice the power density of a comparable design without the shield. The thermal management system has been designed for the proposed motor. The result is a machine that satisfies requirements for electric aviation propulsion applications.

23 October 2019 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
DZDanlu Zhang
Danlu Zhang
MSMike D Sumption
Mike D Sumption
MMMilan Majoros
Milan Majoros
CKChris Joseph Kovacs
Chris Joseph Kovacs
ECEdward W Collings
Edward W Collings
MMMichael A Martens
Michael A Martens
The development of coils that can survive a quench is crucial for demonstrating the viability of MgB2-based main magnet coils used in MRI systems. Here we have studied the performance and quench properties of a large (outer diameter: 901 mm; winding pack: 44 mm thick × 50.6 mm high) conduction-cooled, react-and-wind (R&W), MgB2 superconducting coil. Minimum quench energy (MQE) values were measured at several coil operating currents (Iop), and distinguished from the minimum energy needed to generate a normal zone (MGE). During these measurements, normal zone propagation velocities (NZPV) were also determined using multiple voltage taps placed around the heater zone. The conduction cooled coil obtained a critical current (Ic) of 186 A at 15 K. As the operating currents (Iop) varied from 80 A to 175 A, MQE ranged from 152 J to 10 J, and NZPV increased from 1.3 to 5.5 cm/s. Two kinds of heater were involved in this study: (1) a localized heater (“test heater”) used to initiate the quench, and (2) a larger “protection heater” used to protect the coil by distributing the normal zone after a quench was detected. The protection heater was placed on the outside surface of the coil winding. The test heater was also placed on the outside surface of the coil at a small opening made in the protection heater. As part of this work, we also developed and tested an active protection scheme for the coil. Such active protection schemes are of great interest for MgB2-based MRIs because they permit exploitation of the relatively large MQE values of MgB2 to enable the use of higher Je values which in turn lead to competitive MgB2 MRI designs. Finally, the ability to use a quench detection voltage to fire a protection heater as part of an active protection scheme was also demonstrated.