A react-and-wind MgB 2 coil segment for a conduction-cooled magnetic resonance imaging (MRI) machine has been fabricated and tested. The coil was developed as part of a collaborative effort on a conduction-cooled, MgB 2 -based, whole-body MRI image guided radiation therapy device. This study focuses on the fabrication, winding, instrumentation, cooling, and initial critical current ( Ic ) testing of this near-full-size MgB 2 segment coil. The coil was 0.9 m in diameter; the winding pack, 44.0 mm wide × 50.6 mm high, used 1.7 km of an 18 filament MRI-style conductor with Nb chemical barriers, Cu interfilamentary matrices, and an outer monel sheath. The conductor was insulated and reacted before winding onto a stainless steel former. The coil was instrumented with Cernox and E-type thermocouple temperature sensors, strain sensors, and voltage taps. The conduction-cooled coil was mounted in a cryostat capable of accepting coils of up to 0.9 m in diameter and 0.5 m in height. Critical current measurements were performed as a function of temperature during a controlled heating of the coil. The operational target was I = 200 A at 13 K. The full magnet was designed to produce 0.75 T in the imaging area (at I = 200 A), with a maximum field of 1.93 T in the winding. The single segment coil measured here exceeded this operation specification, with an Ic of 280 A at 15 K and a maximum field 1.93 T in the winding. The coil was modeled using a finite element method, and a load line plot showed that 100% of short sample was reached at 21.5 K and above. These measurements demonstrate the viability of conduction-cooled MgB 2 background coils as replacements for liquid helium cooled NbTi background coils in future MRI devices.
23 October 2019 in Superconductor Science and Technology
The development of coils that can survive a quench is crucial for demonstrating the viability of MgB2-based main magnet coils used in MRI systems. Here we have studied the performance and quench properties of a large (outer diameter: 901 mm; winding pack: 44 mm thick × 50.6 mm high) conduction-cooled, react-and-wind (R&W), MgB2 superconducting coil. Minimum quench energy (MQE) values were measured at several coil operating currents (Iop), and distinguished from the minimum energy needed to generate a normal zone (MGE). During these measurements, normal zone propagation velocities (NZPV) were also determined using multiple voltage taps placed around the heater zone. The conduction cooled coil obtained a critical current (Ic) of 186 A at 15 K. As the operating currents (Iop) varied from 80 A to 175 A, MQE ranged from 152 J to 10 J, and NZPV increased from 1.3 to 5.5 cm/s. Two kinds of heater were involved in this study: (1) a localized heater (“test heater”) used to initiate the quench, and (2) a larger “protection heater” used to protect the coil by distributing the normal zone after a quench was detected. The protection heater was placed on the outside surface of the coil winding. The test heater was also placed on the outside surface of the coil at a small opening made in the protection heater. As part of this work, we also developed and tested an active protection scheme for the coil. Such active protection schemes are of great interest for MgB2-based MRIs because they permit exploitation of the relatively large MQE values of MgB2 to enable the use of higher Je values which in turn lead to competitive MgB2 MRI designs. Finally, the ability to use a quench detection voltage to fire a protection heater as part of an active protection scheme was also demonstrated.
13 February 2025 in IEEE Transactions on Applied Superconductivity
The High Rigidity Spectrometer (HRS) project is a critical expansion of the Facility for Rare Isotope Beams (FRIB), designed to transport high-emittance rare isotope beams with magnetic rigidities of up to 8 Tesla-meters. The HRS consists of two main segments: the upstream High Transmission Beamline (HTBL) and the downstream Spectrometer Section (SPS). This paper presents the design feature of the HTBL's superconducting magnets, which include eight quadrupole triplets and four dipoles. Two different approaches for the quadrupole magnets are explored: the iron-dominated and coil-dominated designs, each with distinct electromagnetic characteristics and manufacturing techniques incorporating nested higher-order multipoles. The dipole design builds upon the proven technology of FRIB's existing switching dipoles, benchmarked from the National Superconducting Cyclotron Laboratory (NSCL) era. Here, we discuss the advantages and limitations of the proposed design options and their performance to meet HTBL operational requirements. Insights gained through FRIB's design advancements and challenges encountered in developing high-performance superconducting magnets for the HRS project are also presented.
A series of SnO 2 added MgB 2 bulk superconductors were prepared by in situ route to study the effect of oxygen doping on superconducting and structural properties of MgB 2 . Several (MgB 2 ) 1-x (SnO 2 ) x samples were fabricated with x ranging from 0, 3 wt%, 4 wt%, and 6 wt%. Upper critical field (B c2 ) and irreversible field (B irr ) were measured by physical property measurement system. Thermal analysis was performed on the as-received SnO 2 powder. Critical current densities (J cm ) were obtained at 4.2 K using magnetic measurement. X-ray diffraction results showed evidence of full SnO 2 decomposition in all the doped bulk samples and a shift of a-axis in MgB 2 lattice was seen. Oxygen was successfully released during heat treatment, yet no enhancement of B C2 or B irr was seen, indicating that oxygen atoms did not end up in the host lattice. Further exploration of different processing procedures is still needed in order to get oxygen substitution on the host lattice sites.