Qiuyan Luo

Qiuyan Luo

Auto-generated profile, based on publicly available information

Qiuyan Luo

Shenzhen Key Laboratory of Photonics and Biophotonics, College of Physics and Optoelectronic Engineering, Key Laboratory of Optoelectronic Devices and Systems of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WFWenyong Fu
Wenyong Fu
QLQiuyan Luo
Qiuyan Luo
JHJunkun Huang
Junkun Huang
XDXindong Duan
Xindong Duan
YLYubo Liao
Yubo Liao
HCHouzhi Cai
Houzhi Cai
X-ray diode is an essential instrument for the measurement of the radiation flow in the inertial confinement fusion (ICF) experiment. The time resolution of the traditional X-ray diode is about 100 ps, which needs improvement. A newly electronic pulse-dilation technique can greatly improve the time resolution of the high-speed diagnostic instrument. Here, an ultrafast X-ray diode with electronic pulse-dilation technique is presented, which includes a pulse-dilation device and an anode electron detector. The pulse-dilation X-ray diode is theoretical and experimental researched. The time resolution of the X-ray diode is approximately 261 ps without electronic signal pulse-dilation, and it will be improved to 19 ps by using the pulse-dilation technique.

19 October 2022 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
QLQiuyan Luo
Qiuyan Luo
KLKaixuan Lin
Kaixuan Lin
JCJiajie Chen
Jiajie Chen
JWJiaheng Wang
Jiaheng Wang
JHJunkun Huang
Junkun Huang
HCHouzhi Cai
Houzhi Cai
Three magnetic focusing framing tubes are designed based on short magnetic lenses, long magnetic lenses, and hybrid lenses consisting of short and long magnetic lenses, and the spatial resolution characteristics of these framing tubes are theoretically studied. The excitation current of the short magnetic lenses is 0.15 A, the imaging magnification ratio is 1:1, and the spatial resolution is better than 50 $\mu $ m. The spatial resolution difference is 23.08% within the 30-mm off-axis. The spatial resolution of the long magnetic lens framing tube is better than 20 $\mu $ m, and the spatial resolution difference is 10.71%. However, the long magnetic lenses require a large excitation current of 26.25 A. For the hybrid magnetic lenses, the excitation current of 0.15 A is used to achieve a spatial resolution of better than 20 $\mu $ m and a spatial resolution difference of 8.11%. The simulation results show that the hybrid magnetic lenses are the best imaging method among these three lenses. A high spatial resolution and spatial resolution uniformity can be simultaneously obtained by using a small excitation current in the hybrid magnetic lens framing tube.

22 April 2022 in Photonics
Verified
Journal Article
Open access
PDF file
HCHouzhi Cai
Houzhi Cai
KLKaixuan Lin
Kaixuan Lin
QLQiuyan Luo
Qiuyan Luo
DWDong Wang
Dong Wang
JHJunkun Huang
Junkun Huang
JLJinyuan Liu
Jinyuan Liu
A two-dimensional ultrafast X-ray imager (UXI) composed of a time-dilation device, an electron-beam imaging unit, a gated microchannel plate (MCP) framing tube, and a pulser was developed. The time-dilation device extends the time spread of the electron signal generated by the pulsed photocathode (PC), and the electron-beam imaging unit images the electron pulse from PC to MCP. Finally, the gated MCP framing tube samples the dilated electron pulse. The time resolution and image size of the UXI were measured with an X-ray generated by a terawatt laser targeting device. When a driving pulse with a 2 V/ps slope is applied to the PC, the measured time resolution is 21 ps, and the image size is 12 mm × 3.9 mm. Furthermore, the image size varies with the time resolution. The results show that as the time resolution improves, the image size decreases. The use of two opposite-transmission PC driving pulses could improve the image size. Moreover, the measured UXI spatial resolution is 5 lp/mm, and the spatial resolution will be worse with the increasing off-axis distance.

20 October 2022 in Applied Optics
Verified
Journal Article
Closed access
PDF file
KLKaixuan Lin
Kaixuan Lin
QLQiuyan Luo
Qiuyan Luo
JCJiajie Chen
Jiajie Chen
JWJiaheng Wang
Jiaheng Wang
JHJunkun Huang
Junkun Huang
HCHouzhi Cai
Houzhi Cai
The temporal resolution uniformity of a time-dilation framing camera is studied, and the ideal photocathode (PC) pulse curve is determined, while the temporal magnification factor is kept constant. To obtain the ideal curve, a series of linear pulses with the same slope are superposed. The variance in the temporal resolution and the number of linear pulses required are compared, while the superposition results with different slopes are used as the PC voltage. As the slope of the linear pulses decreases, the variance decreases, which means that the uniformity of the temporal resolution is improved, but the number of linear pulses required increases. In this study, linear pulses with a slope of 1 V/ps are superposed. Nine linear pulses with a front edge time of 200 ps, amplitude of 200 V, and flat top time of 1 ns are superimposed to approximate the ideal PC pulse curve with a constant temporal magnification factor of 10; the trigger times of the pulses are 0, 0, 0, 185, 200, 350, 450, 605, and 790 ps. When the superposition result is applied as the PC voltage and the measured signal is synchronized to the PC pulse at 128 ps–1 ns, the temporal resolution error is within 5%.

24 October 2024 in Applied Optics
Verified
Journal Article
Closed access
HCHouzhi Cai
Houzhi Cai
ZDZhuoming Du
Zhuoming Du
QLQiuyan Luo
Qiuyan Luo
YMYoulin Ma
Youlin Ma
JLJinyuan Liu
Jinyuan Liu
LXLijuan Xiang
Lijuan Xiang
In an inertial confinement fusion (ICF) ultrafast diagnostic system that is based on electron beam time-dilation, an ultrafast electrical pulse is used to excite a microstrip photocathode (PC), which generates a varying PC voltage to obtain a photoelectron velocity that varies with emission time. The photoelectron beam achieves time-dilation through the drift process and is then detected by a time-resolved sensor, thereby increasing the temporal resolution of the diagnostic system. A pulse time-dilation diagnostic system is simulated, while the sensor is a gated microchannel plate (MCP) detector with a temporal resolution of 100 ps and an excitation pulse on a PC with a slope of 3 V/ps; the diagnostic system achieves a temporal resolution of 11.12 ps. However, the excitation pulse creates a voltage difference across the PC. A voltage difference of 900 V can be acquired for a PC length of 60 mm, which yields a nonuniform spatial resolution ranging from 30.4 µm to approximately 3000 µm. Furthermore, the voltage difference across the PC also limits the frame size to 2.2 mm along the pulse propagation direction according to the simulation results. To achieve a uniform spatial resolution and a larger frame size, a dual-pulse excitation technique on a PC is presented, which is the technique to symmetrically apply voltage pulses at both ends of the PC microstrip. The theoretical results show that this technique will improve the uniformity of the PC voltage spatial distribution. When the PC pulse slope is 3 V/ps and the dual-pulse excitation technique is employed, the diagnostic system has a temporal resolution of 5.91 ps and a uniform spatial resolution of 30.4 µm. Furthermore, the frame size along the pulse propagation direction is improved to the effective length of the microstrip PC.

1 January 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LXLijuan Xiang
Lijuan Xiang
LHLiangnv Huang
Liangnv Huang
ZDZhiying Deng
Zhiying Deng
XCXuan Chen
Xuan Chen
ZDZhuoming Du
Zhuoming Du
HCHouzhi Cai
Houzhi Cai