5 January 2024 in IEEE Sensors Journal
X-ray diode is an essential instrument for the measurement of the radiation flow in the inertial confinement fusion (ICF) experiment. The time resolution of the traditional X-ray diode is about 100 ps, which needs improvement. A newly electronic pulse-dilation technique can greatly improve the time resolution of the high-speed diagnostic instrument. Here, an ultrafast X-ray diode with electronic pulse-dilation technique is presented, which includes a pulse-dilation device and an anode electron detector. The pulse-dilation X-ray diode is theoretical and experimental researched. The time resolution of the X-ray diode is approximately 261 ps without electronic signal pulse-dilation, and it will be improved to 19 ps by using the pulse-dilation technique.
19 October 2022 in IEEE Transactions on Plasma Science
Three magnetic focusing framing tubes are designed based on short magnetic lenses, long magnetic lenses, and hybrid lenses consisting of short and long magnetic lenses, and the spatial resolution characteristics of these framing tubes are theoretically studied. The excitation current of the short magnetic lenses is 0.15 A, the imaging magnification ratio is 1:1, and the spatial resolution is better than 50 $\mu $ m. The spatial resolution difference is 23.08% within the 30-mm off-axis. The spatial resolution of the long magnetic lens framing tube is better than 20 $\mu $ m, and the spatial resolution difference is 10.71%. However, the long magnetic lenses require a large excitation current of 26.25 A. For the hybrid magnetic lenses, the excitation current of 0.15 A is used to achieve a spatial resolution of better than 20 $\mu $ m and a spatial resolution difference of 8.11%. The simulation results show that the hybrid magnetic lenses are the best imaging method among these three lenses. A high spatial resolution and spatial resolution uniformity can be simultaneously obtained by using a small excitation current in the hybrid magnetic lens framing tube.
20 October 2022 in Applied Optics
The temporal resolution uniformity of a time-dilation framing camera is studied, and the ideal photocathode (PC) pulse curve is determined, while the temporal magnification factor is kept constant. To obtain the ideal curve, a series of linear pulses with the same slope are superposed. The variance in the temporal resolution and the number of linear pulses required are compared, while the superposition results with different slopes are used as the PC voltage. As the slope of the linear pulses decreases, the variance decreases, which means that the uniformity of the temporal resolution is improved, but the number of linear pulses required increases. In this study, linear pulses with a slope of 1 V/ps are superposed. Nine linear pulses with a front edge time of 200 ps, amplitude of 200 V, and flat top time of 1 ns are superimposed to approximate the ideal PC pulse curve with a constant temporal magnification factor of 10; the trigger times of the pulses are 0, 0, 0, 185, 200, 350, 450, 605, and 790 ps. When the superposition result is applied as the PC voltage and the measured signal is synchronized to the PC pulse at 128 ps–1 ns, the temporal resolution error is within 5%.
24 October 2024 in Applied Optics
In an inertial confinement fusion (ICF) ultrafast diagnostic system that is based on electron beam time-dilation, an ultrafast electrical pulse is used to excite a microstrip photocathode (PC), which generates a varying PC voltage to obtain a photoelectron velocity that varies with emission time. The photoelectron beam achieves time-dilation through the drift process and is then detected by a time-resolved sensor, thereby increasing the temporal resolution of the diagnostic system. A pulse time-dilation diagnostic system is simulated, while the sensor is a gated microchannel plate (MCP) detector with a temporal resolution of 100 ps and an excitation pulse on a PC with a slope of 3 V/ps; the diagnostic system achieves a temporal resolution of 11.12 ps. However, the excitation pulse creates a voltage difference across the PC. A voltage difference of 900 V can be acquired for a PC length of 60 mm, which yields a nonuniform spatial resolution ranging from 30.4 µm to approximately 3000 µm. Furthermore, the voltage difference across the PC also limits the frame size to 2.2 mm along the pulse propagation direction according to the simulation results. To achieve a uniform spatial resolution and a larger frame size, a dual-pulse excitation technique on a PC is presented, which is the technique to symmetrically apply voltage pulses at both ends of the PC microstrip. The theoretical results show that this technique will improve the uniformity of the PC voltage spatial distribution. When the PC pulse slope is 3 V/ps and the dual-pulse excitation technique is employed, the diagnostic system has a temporal resolution of 5.91 ps and a uniform spatial resolution of 30.4 µm. Furthermore, the frame size along the pulse propagation direction is improved to the effective length of the microstrip PC.
1 January 2026 in IEEE Sensors Journal