1 June 2014 in Optics Communications
29 May 2024 in Photoacoustics
Differential photoacoustic spectroscopy (PAS) for flow gas detection based on single microphone is innovatively proposed and experimentally demonstrated. Unlike the traditional systems, only one microphone is used to suppress flowing gas noise. Wavelength modulation spectroscopy and second harmonic detection technique are applied in this PAS system with Q-point demodulation for acetylene (C2H2) gas detection. The experiment is conducted at 1 atm and 300 K. Different concentrations and flow rates of C2H2 from 0 sccm to 225 sccm are detected by using nitrogen (N2) as the carrier gas, which indicates that the system can respond well to flowing gases while maintaining the noise at the same level. The system response time decreases to 3.58 s while the gas velocity is 225 sccm. The detection limit of 43.97 ppb with 1 s integration time and normalized noise equivalent absorption (NNEA) coefficient of 4.0 × 10-9 cm-1 W Hz-1/2 is achieved at the flow rate of 225 sccm. The firstly proposed differential PAS based on single microphone greatly simplifies the system structure for flow gas detection, which provides a novel route for development of PAS with significant practical implementation prospects.
1 May 2024 in Photonics Research
Infrasound detection is important in natural disasters monitoring, military defense, underwater acoustic detection, and other domains. Fiber-optic Fabry–Perot (FP) acoustic sensors have the advantages of small structure size, long-distance detection, immunity to electromagnetic interference, and so on. The size of an FP sensor depends on the transducer diaphragm size and the back cavity volume. However, a small transducer diaphragm size means a low sensitivity. Moreover, a small back cavity volume will increase the low cut-off frequency of the sensor. Hence, it is difficult for fiber-optic FP infrasound sensors to simultaneously achieve miniaturization, high sensitivity, and extremely low detectable frequency. In this work, we proposed and demonstrated a miniaturized and highly sensitive fiber-optic FP sensor for mHz infrasound detection by exploiting a Cr-Ag-Au composite acoustic-optic transducer diaphragm and a MEMS technique-based spiral micro-flow hole. The use of the spiral micro-flow hole as the connecting hole greatly reduced the volume of the sensor and decreased the low-frequency limit, while the back cavity volume was not increased. Combined with the Cr-Ag-Au composite diaphragm, a detection sensitivity of −123.19 dB re 1 rad/μPa at 5 Hz and a minimum detectable pressure (MDP) of 1.2 mPa/Hz1/2 at 5 Hz were achieved. The low detectable frequency can reach 0.01 Hz and the flat response range was 0.01–2500 Hz with a sensitivity fluctuation of ±1.5 dB. Moreover, the size of the designed sensor was only 12 mm×Φ12.7 mm. These excellent characteristics make the sensor have great practical application prospects.
5 August 2024 in Photoacoustics
A proof-of-concept on-beam tuning-fork-enhanced photoacoustic sensor based on an open-closed single-tube acoustic-microresonator (AmR) was proposed and investigated for the first time, to the best of our knowledge. Due to the high acoustic amplification effect, the open-closed AmR improved the detection sensitivity by 54 times with respect to the bare tuning fork (TF). Compared to traditional dual-tube/single-tube on-beam spectrophone configuration, the developed approach significantly facilitates the laser beam alignment and reduces the sensor size and gas consumption. A 6.6 kHz low-frequency custom aluminum alloy TF was employed as the acoustic transducer to detect the photoacoustic signal. The vibration of TF was measured by a fiber-optic Fabry-Pérot (FP) interferometer (FPI). The modulation depth, tube length and laser power were experimentally optimized and evaluated in detail. An acetylene (C2H2) 1σ minimum detection limit (MDL) of 6.3 ppb was obtained with a high laser power of ∼ 500 mW, corresponding to a normalized noise equivalent absorption (NNEA) coefficient of 6.5 × 10−9 cm−1 W/Hz1/2. The compact spectrophone size and all-fiber measurement method can make the PAS-based sensor have great application prospects in dissolved gases detection in transformer oil, remote gas detection, space-limited gas detection, and etc.