Fatma Meriç Yılmaz

Fatma Meriç Yılmaz

Auto-generated profile, based on publicly available information

Fatma Meriç Yılmaz

Department of Medical Biochemistry, Ankara Yıldırım Beyazıt University, Faculty of Medicine, Ankara, Türkiye

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2021 in Turkish Journal of Biochemistry
Verified
Journal Article
Open access
PDF file
SESerpil Erdogan
Serpil Erdogan
RFRidvan Firat
Ridvan Firat
GAGamze Avcioglu
Gamze Avcioglu
GYGulsen Yilmaz
Gulsen Yilmaz
ÖEÖzcan EREL
Özcan EREL
FYFatma Meric Yilmaz
Fatma Meric Yilmaz
Objectives: As one of the most widely used tests, the erythrocyte sedimentation rate (ESR) is a measurement of sedimentation reaction in blood samples. Although the recommended method for ESR measurement is the Westergren method, this method has some disadvantages in comparison with automated ESR systems. In this cross-sectional study, we aimed to compare Vision C with the Westergren method. Methods: The Vision C automated ESR system and the modified Westergren method were compared using K 3 EDTA-containing tubes and citrated blood tubes from randomly selected 100 patients. Precision, bias, and interference calculations were performed. Results: The mean difference between the Vision C (room temperature) and the modified Westergren method was 22.8 ± 26.6 mm/h (95% CI for the mean was 17.50–28.08 mm/h). The mean difference between the Vision C (18 °C) and the modified Westergren method was 27.4 ± 30.6 mm/h (95% CI for the mean was 21.3–33.5 mm/h). The calculated regression analysis equation was “ y = 0.263 + 1.053x ” and “ y = − 0.530 +  0.851x ” for the Vision C (room temperature) and the Vision C (18 °C), respectively. The imprecision values ranged at 7.55–17.09%. According to our external quality control results, bias was 11.11 and 9.66 for the low- and high-level samples, respectively. Conclusions: The Vision C automated ESR system has a comparable analytical performance with the modified Westergren method. The Vision C automated system may be utilized in ESR measurements with quality control evaluations. Nevertheless, temperature correction using Manley’s monogram causes an important negative bias and should be taken into consideration during the evaluation of the Vision C results.

20 October 2023 in Turkish Journal of Biochemistry
Verified
Journal Article
Open access
PDF file
GAGamze Avcioglu
Gamze Avcioglu
GYGulsen Yilmaz
Gulsen Yilmaz
SSSafak Yalcin Sahiner
Safak Yalcin Sahiner
LKL. Didem Kozaci
L. Didem Kozaci
CBCeylan Bal
Ceylan Bal
FYFatma Meric Yilmaz
Fatma Meric Yilmaz
Objectives: The aim of this study was to compare the analytical performance of the KIMS (kinetic interaction of microparticles in solution) immunochemical method with a validated in-house and a commercial LC-MS/MS method. Methods: The urine samples of the 100 subjects were included in the present study. The urine samples were analysed with Roche DAT immunochemical method based on KIMS method. In-house LC-MS/MS method was validated for 58 parameters according to the CLSI C62-A recommendations with the following parameters: matrix effect, lower limit of quantification (LLOQ), linearity, intra-day and inter-day precision and accuracy. Eureka Lab Division Drugs of Abuse kit was used as the commercial LC-MS/MS method. Results: The immunochemical method had a satisfactory performance with specificity, sensitivity and accuracy values above 80 % and met the DRUID recommendation except benzodiazepines. The sensitivity and specificity of the immunochemical method were between 97–100 % and 84–100 %, respectively (except for benzodiazepines). The bias obtained for THC-COOH, morphine and codeine parameters were −17.5, 24.6 and 43.6 between two LC-MS/MS methods. The commercial method had a tendency to have a negative bias except for cannabinoids. Conclusions: The analytical performance of the KIMS-based urine immunochemical method was found to be satisfactory for the intended use, except for benzodiazepines. The validated urine in-house LC-MS/MS method was found to be a good alternative for confirmation of substance abuse.

1 April 2025 in Journal of Disaster Research
Verified
Journal Article
Closed access
KKKerem Kinik
Kerem Kinik
CÇCüneyt Çalışkan
Cüneyt Çalışkan
HKHüseyin Koçak
Hüseyin Koçak
FYFatma Meriç Yılmaz
Fatma Meriç Yılmaz
This study examines the pivotal role of the Turkish Red Crescent Communication Centre (KİMER) during the February 6, 2023, earthquakes in Kahramanmaraş, Türkiye—termed as the “disaster of the century.” Employing a cross-sectional descriptive epidemiological analysis, the research focuses on KİMER’s crisis communication efforts, analyzing the volume and nature of calls to KİMER’s Call Centre and assessing their impact on disaster management. Data extracted from KİMER’s database from February 6 to December 15, 2023, alongside operational reports and interviews with staff and volunteers, form the basis of both qualitative and quantitative analyses. Findings indicate KİMER addressed over 1.1 million requests through diverse channels, including call centers, social media, and chatbots, showcasing a high degree of adaptability and efficiency. Geographic analysis of requests underscores the direct correlation between disaster impact and assistance demand, highlighting the importance of targeted response strategies. The predominance of information-seeking calls reveals a critical need for timely, accurate communication during crises. The study emphasizes the efficacy of KİMER’s digital platforms and specialized support for vulnerable groups, suggesting enhancements in digital tool usage and geographically focused plans for future disaster management. Ultimately, this research underscores the significance of comprehensive, adaptable communication strategies in disaster response, offering insights for improving crisis management frameworks in Türkiye and potentially in similar contexts globally.

3 February 2020 in Istanbul Medical Journal
Verified
Journal Article
Closed access
EOEsra Fırat Oguz
Esra Fırat Oguz
SMSemra Mungan
Semra Mungan
FYFatma Meriç Yılmaz
Fatma Meriç Yılmaz
MEMüjgan Ercan
Müjgan Ercan
SUSema Uysal
Sema Uysal

11 June 2026 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
MÖMehmet İbRahim Özet
Mehmet İbRahim Özet
FAFatih Acehan
Fatih Acehan
MKMerve Kaygısız
Merve Kaygısız
MKMustafa Abdulgani Kurt
Mustafa Abdulgani Kurt
HAHalil Arslan
Halil Arslan
IAIhsan Ates
Ihsan Ates
Hypertension and subclinical atherosclerosis are major contributors to cardiovascular morbidity. Asprosin, a fasting-induced adipokine involved in glucose homeostasis and inflammation, has been proposed as a novel metabolic biomarker. This study investigated the relationship between serum asprosin levels and subclinical atherosclerosis in patients with primary hypertension. A total of 114 patients with primary hypertension and 62 age- and sex-matched healthy controls were enrolled between July 2022 and June 2023. Coronary artery calcium (Agatston) score was used to assess subclinical atherosclerosis. Serum asprosin concentrations were measured using the ELISA method. Correlation, regression, and ROC analyses were performed to identify determinants and discriminatory performance. Serum asprosin levels were significantly higher in hypertensive patients than in controls (3.0 ± 0.9 ng/mL vs. 2.6 ± 0.8 ng/mL, p = 0.012). In hypertensive individuals, increasing age, blood pressure, and ASCVD risk score were independently associated with higher atherosclerotic burden, whereas the neutrophil-to-lymphocyte ratio (NLR) was inversely related (p < 0.05). ROC analysis showed that serum asprosin could discriminate hypertensive patients with subclinical atherosclerosis (AUC = 0.710 [95% CI: 0.62-0.80, p = 0.001]) at a cut-off > 3.05 ng/mL, with 69% sensitivity and 72% specificity. Serum asprosin levels were elevated in patients with primary hypertension and may reflect metabolic-inflammatory alterations rather than directly indicate subclinical atherosclerosis. Given its modest discriminatory performance, serum asprosin should be considered an exploratory and complementary biomarker, not a standalone clinical tool. Larger longitudinal studies are required to validate its clinical relevance.Clinical trial numberNot applicable.

25 December 2020 in Harran Üniversitesi Tıp Fakültesi Dergisi
Verified
Journal Article
Closed access
PDF file
EAEmiş Deniz AKBULUT
Emiş Deniz AKBULUT
SESerpil Erdoğan
Serpil Erdoğan
SASerkan Akbulut
Serkan Akbulut
FYFatma Meriç Yilmaz
Fatma Meriç Yilmaz
Amaç: Böbrek fonksiyonun bir belirteci olarak bilinen sistatin C’nin tümör gelişiminde inhibör etki gösterdiği düşünülmektedir. Çalışmada bilinen böbrek hastalığı olmayan mide ve kolorektal kanserli olgularla sağlıklı bireylerin serum sistatin C düzeyleri arasındaki olası farkın, serum karsinoembriyonik antijen (CEA) ve karbohidrat antijen 19-9 (CA19-9) düzeyleri arasındaki ilişkinin incelenmesi amaçlanmıştır.Materyal ve metod: Çalışmaya serum kreatinin konsantrasyonu referans aralığı içerisinde yer alan ve tahmini glomerüler filtrasyon hızı (eGFH) >60 mL/dk olan mide (n=35) ve kolorektal kanserli (n=35) hastalar ile bilinen herhangi bir sistemik hastalığı olmayan sağlıklı bireyler (n=40) dahil edilmiştir. CEA ve CA 19-9 testleri kemilüminesans temelli immün yöntemle (Beckman Coulter UniCel® DxI 800 Immunoassay System) Sistatin C analizi ise partikül yüzeyi genişletilmiş immünotürbidimetrik yöntem (Roche Diagnostics Cobas® Modular P®) kullanılarak yapılmıştır.Bulgular: Mide, KRK (kolorektal kanser) ve kontrol grupları arasında serum kreatinin konsantrasyonu açısından önemli fark izlenmezken (p=0,571) sistatin C düzeyi hasta gruplarında kontrol grubuna göre anlamlı olarak daha yüksek izlenmiştir (p<0,001). Çoklu değişkenli lojistik regresyon analizinde sistatin C düzeyinin yüksek olması üzerinde sırasıyla; kreatinin düzeyi ve kanser hastası olmanın etkili olduğu bulunmuştur. Kreatinindeki her 0,1 mg/dL’lik artış sistatin C düzeyinin yüksek olma ihtimalini 2,531 kat (%95 güven aralığı: 1,562-4,100) arttırmaktadır (p0,05). Sonuç: Mide veya kolorektal kanserli olgularda serum sistatin C düzeyinin böbrek fonksiyonunun yanısıra kanser varlığından da etkilenebileceği gözlenmiştir.Anahtar Kelimeler: Sistatin C, Katepsin, Mide Kanseri, Kolorektal Kanser