Julian Haas

Julian Haas

Auto-generated profile, based on publicly available information

Julian Haas

Hahn-Schickard, Ulm, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Osteoarthritis and Cartilage
Verified
Journal Article
Open access
DWD. Warnecke
D. Warnecke
JBJ. Balko
J. Balko
JHJ. Haas
J. Haas
RBR. Bieger
R. Bieger
FLF. Leucht
F. Leucht
LDL. Dürselen
L. Dürselen
Because the literature relating to the influence of degeneration on the viscoelasticity and tissue composition of human lateral menisci remains contradictory or completely lacking, the aim of this study was to fill these gaps by comprehensively characterising the biomechanical properties of menisci with regard to the degree of degeneration. Meniscal tissue from 24 patients undergoing a total knee replacement was collected and the degeneration of each region classified according to Pauli et al. For biomechanical characterisation, compression and tensile tests were performed. Additionally, the water content was determined and infrared (IR) spectroscopy was applied to detect changes in the structural composition, particularly of the proteoglycan and collagen content. With an increasing degree of degeneration, a significant decrease of the equilibrium modulus was detected, while simultaneously the water content and the hydraulic permeability significantly increased. However, the tensile modulus displayed a tendency to decrease with increasing degeneration, which might be due to the significantly decreasing amount of collagen content identified by the IR measurements. The findings of the current study may contribute to the understanding of meniscus degeneration, showing that degenerative processes appear to mainly worsen viscoelastic properties of the inner circumference by disrupting the collagen integrity.

14 August 2018 in The Analyst
Verified
Journal Article
Open access
PDF file
JHJulian Haas
Julian Haas
ECErnesto Vargas Catalán
Ernesto Vargas Catalán
PPPierre Piron
Pierre Piron
Mikael KarlssonMikael Karlsson
Mikael Karlsson
BMBoris Mizaikoff
Boris Mizaikoff
Recently emerging broadly tunable quantum cascade lasers (tQCL) emitting in the mid-infrared (MIR) are a versatile alternative to well established thermal emitters in combination with interferometers as applied in Fourier transform infrared (FTIR) spectroscopy. The wide and highly spectrally resolved wavelength tuning characteristics along with superior spectral energy density renders laser-based vibrational spectroscopy methods an efficient alternative vs. conventional molecular spectroscopies. Using diamond in attenuated total reflection (ATR) sensing formats benefits from the physical robustness and chemical resistivity of the internal reflective element (IRE) material. While inherent material absorption frequently limits the optical path length within diamond ATR elements, the herein presented design combining bright tQCLs with a multi-reflection polycrystalline diamond (PCD) ATR element enables an optical beam path length of approximately 5 cm. Thereby, sensitive spectroscopic measurements in the MIR are enabled. As an example, non-invasive glucose monitoring in human saliva is examined, highlighting the potential benefits of the proposed analytical concept with regards to exquisite sensitivity and selectivity in combination with a robust sensing interface, i.e., diamond. This approach paves the way towards directly analyzing molecular constituents in complex and potentially corrosive biomedical and biochemical matrices.

5 April 2019 in The Analyst
Verified
Journal Article
Closed access
PDF file
JHJulian Haas
Julian Haas
AMAnja Müller
Anja Müller
LSLorenz Sykora
Lorenz Sykora
BMBoris Mizaikoff
Boris Mizaikoff
The analytical performance of micromachined μ-groove silicon attenuated total reflection (ATR) elements has been evaluated in a comparison of Fourier-transform infrared (FTIR) and quantum cascade laser (QCL) spectroscopy operating at mid-infrared (MIR) wavelengths. μ-Groove silicon ATR elements are highly efficient micromachined waveguides fabricated at a wafer scale at such low cost that they may be considered a consumable for single-time-use, e.g., in medical application scenarios. Herein, exemplary analytes haven been used for reliably evaluating their analytical performance (i.e., acetate and carbonate) in terms of sensitivity, noise level, and achievable limits of detection in a comparison of broadband vs. narrowband infrared spectroscopy.

14 March 2019 in RSC Advances
Verified
Journal Article
Open access
PDF file
JHJulian Haas
Julian Haas
PAPhilipp Artmann
Philipp Artmann
BMBoris Mizaikoff
Boris Mizaikoff
Micro-ring resonators with a decoupling waveguide have been fabricated from thin-film GaAs/Al0.2Ga0.8As waveguides accommodating mid-infrared wavelengths, and were characterized in detail via thermal tuning.

8 June 2018 in ACS Omega
Verified
Journal Article
Open access
JHJulian Haas
Julian Haas
ECErnesto Vargas Catalán
Ernesto Vargas Catalán
PPPierre Piron
Pierre Piron
FNFredrik Nikolajeff
Fredrik Nikolajeff
LÖLars Österlund
Lars Österlund
BMBoris Mizaikoff
Boris Mizaikoff
Photonic design and optimization of thin-film polycrystalline diamond waveguides are shown, serving as advanced evanescent field transducers in the mid-infrared fingerprint regime (2000–909 cm–1; 5–11 μm). Design constraints inherent to optical/system considerations and the material were implemented in a finite element method (FEM)-based simulation method that allowed three-dimensional modeling of the overall structure. Thus, lateral mode confinement, attenuation in the direction of radiation propagation, and physical resilience were evaluated. In a final step, the designed structures were fabricated, and their utility in combination with a broadly tunable external cavity quantum cascade laser for chemical sensing of a liquid phase analyte was demonstrated.

10 December 2021 in Applied Spectroscopy
Verified
Journal Article
Open access
PDF file
ATAndrea Teuber
Andrea Teuber
RSRobert Stach
Robert Stach
JHJulian Haas
Julian Haas
BMBoris Mizaikoff
Boris Mizaikoff
An innovative mid-infrared spectroscopic sensor system based on quantum cascade lasers has been developed. The system combines the versatility of substrate-integrated hollow waveguides (IHWGs) with the robustness of attenuated total reflection (ATR) crystals employed as internal reflection waveguides for evanescent field sensing. IHWGs are highly reflective metal structures that propagate infrared (IR) radiation and were used as light pipes for coupling radiation into the ATR waveguide. The combined IHWG-ATR device has been designed such that the utmost stability and robustness of the optical alignment were ensured. This novel assembly enables evanescent field absorption measurements at yet unprecedently harsh conditions, that is, high pressure and temperature. Combining these advantages, this innovative sensor assembly is perfectly suited for taking ATR spectroscopy into the field where the robustness of the assembly and optical alignment is essential.