8 November 2012 in Analytical Chemistry
1 May 1998 in Spectrochimica Acta Part B: Atomic Spectroscopy
1 January 1999 in Journal of Analytical Atomic Spectrometry
Laser-induced breakdown spectrometry has been evaluated at high temperatures for stainless steel samples. A Q-switched Nd:YAG laser operating at 1064 nm was used to create a microplasma on an AISI 304L stainless steel sample placed inside a laboratory oven. The steel sample was 51.5 cm away from the focusing lens. The temperature of the samples ranged from 25 to 1200 °C. The plasma light was collected by means of a fiber optic bundle, spectrally resolved and then detected by a CCD camera. The effects of sample temperature in the formation of a laser-induced plasma have been studied in terms of its spectral features as well as the morphology of the ablated craters in air at atmospheric pressure. A noticeable dependence of signal emission intensity on sample temperature has been found. Depth profiling of stainless steel samples for several temperature conditions was performed. Results have revealed changes in the superficial composition at temperatures above 600 °C due to the formation of a slag layer of variable thickness, mainly composed of chromium, iron and manganese oxides.
1 December 2005 in Analytica Chimica Acta
1 May 2007 in Applied Spectroscopy
In this work, the capability of laser-induced breakdown spectrometry for the in situ analytical assessment and chemical mapping of the façade of the cathedral of Malaga (Spain) has been demonstrated. The task required the use of a portable laser analyzer that allowed real-time spectral acquisitions in the field. A man-portable laser, based on a Q-switched Nd:YAG laser operating at its fundamental wavelength, has been utilized to generate a LIBS plasma of the sample surface. A chemical characterization of the different materials employed in the construction of this building has been performed. The purpose of this study was to use LIBS spectrochemical analysis to qualitatively discriminate between sandstone, limestone, marble, and cement mortar, which are the main components used in this class of historical monument. The field analysis was performed in two zones: the northern façade and the “girola”; the total areas of analysis of the two regions were 250 m2 and 650 m2, respectively. Chemical images of Si/Ca and Ca/Mg ratios from both parts of the building were generated. During the measurement campaign, a protocol of analysis was chosen so as to achieve an accurate description of the building materials with respectable spatial resolutions.
1 March 1998 in Applied Spectroscopy
Laser-induced breakdown spectrometry (LIBS) has been evaluated for depth profiling of phosphorus doping in silicon. Laser plasmas were formed by focusing a Nd:YAG laser (operating in the second harmonic, 532 nm) on the sample surface. Plasma emission was collected, dispersed, and detected with the use of a charge-coupled device (CCD). Experimental parameters, such as delay time and sample position relative to the laser focal point, were optimized to improve the signal-to-background ratio of phosphorus line emission. Diffusion profiles by LIBS of samples with different phosphorus diffusion steps are shown. Crater depth per pulse and ablated mass per pulse were measured to be 1.2 μm pulse −1 and 50 ng pulse −1 , respectively. The knowledge of depth per pulse permitted the estimation of thickness of the P diffusion layer.