Shaoyan Xia

Shaoyan Xia

Auto-generated profile, based on publicly available information

Shaoyan Xia

School of Optoelectronics, Beijing Institute of Technology 5 South Zhongguancun Street, Haidian District, Beijing, 100081, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SXShaoyan Xia
Shaoyan Xia
HZHaogang Zhu
Haogang Zhu
XLXiaoli Liu
Xiaoli Liu
MGMing Gong
Ming Gong
XHXiaoyong Huang
Xiaoyong Huang
JGJialong Guo
Jialong Guo
To facilitate the analysis and diagnosis of X-ray coronary angiography in interventional surgery, it is necessary to extract vessel from X-ray coronary angiography. However, vessel images of angiography suffer from low quality with large artefacts, which challenges the existing vascular technology. In this paper, we propose a ávessel framework to detect vessels and segment vessels in angiographic vessel data. In this framework, we develop a new matrix decomposition model with gradient sparse in the tensor representation. Then, the energy function with the input of the hierarchical vessel is used in vessel detection and vessel segmentation. Through experiments conducted on angiographic data, we have demonstrated the good performance of the proposed method in removing background structure. We evaluated our method for vessel detection and segmentation in different clinical settings, including LAO/RAO with cranial and caudal angulation, and showed its competitive results compared with eight state-of-the-art methods in terms of extensive qualitative and quantitative evaluation. Our method can remove a large number of background artefacts and obtain a better vascular structure, which has contributed to the clinical diagnosis of coronary artery diseases.

5 July 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SXShaoyan Xia
Shaoyan Xia
Yong HuangYong Huang
Yong Huang
SPShizhao Peng
Shizhao Peng
YWYanfeng Wu
Yanfeng Wu
XTXiaodi Tan
Xiaodi Tan
Phase image in Fourier domain Doppler optical coherence tomography offers additional flow information of investigated samples, which provides valuable evidence towards accurate medical diagnosis. High quality phase images are thus desirable. We propose a noise reduction method for phase images by combining a synthetic noise estimation criteria based on local noise estimator (LNE) and distance median value (DMV) with anisotropic diffusion model. By identifying noise and signal pixels accurately and diffusing them with different coefficients respectively and adaptive iteration steps, we demonstrated the effectiveness of our proposed method in both phantom and mouse artery images. Comparison with other methods such as filtering method (mean, median filtering), wavelet method, probabilistic method and partial differential equation based methods in terms of peak signal-to-noise ratio (PSNR), equivalent number of looks (ENL) and contrast-to-noise ratio (CNR) showed the advantages of our method in reserving image energy and removing noise.