Yong Huang

Dr. Yong Huang

School of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Syed Furqan QadriSyed Furqan Qadri
Syed Furqan Qadri
DADanni AI
Danni AI
GHGuoyu Hu
Guoyu Hu
MAMubashir Ahmad
Mubashir Ahmad
Yong HuangYong Huang
Yong Huang
JYJian Yang
Jian Yang
Precise automatic vertebra segmentation in computed tomography (CT) images is important for the quantitative analysis of vertebrae-related diseases but remains a challenging task due to high variation in spinal anatomy among patients. In this paper, we propose a deep learning approach for automatic CT vertebra segmentation named patch-based deep belief networks (PaDBNs). Our proposed PaDBN model automatically selects the features from image patches and then measures the differences between classes and investigates performance. The region of interest (ROI) is obtained from CT images. Unsupervised feature reduction contrastive divergence algorithm is applied for weight initialization, and the weights are optimized by layers in a supervised fine-tuning procedure. The discriminative learning features obtained from the steps above are used as input of a classifier to obtain the likelihood of the vertebrae. Experimental results demonstrate that the proposed PaDBN model can considerably reduce computational cost and produce an excellent performance in vertebra segmentation in terms of accuracy compared with state-of-the-art methods.

5 February 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
JLJinpeng Liu
Jinpeng Liu
HHHideyoshi Horimai
Hideyoshi Horimai
XLXiao Lin
Xiao Lin
Yong HuangYong Huang
Yong Huang
XTXiaodi Tan
Xiaodi Tan
A novel phase modulation method for holographic data storage with phase-retrieval reference beam locking is proposed and incorporated into an amplitude-encoding collinear holographic storage system. Unlike the conventional phase retrieval method, the proposed method locks the data page and the corresponding phase-retrieval interference beam together at the same location with a sequential recording process, which eliminates piezoelectric elements, phase shift arrays and extra interference beams, making the system more compact and phase retrieval easier. To evaluate our proposed phase modulation method, we recorded and then recovered data pages with multilevel phase modulation using two spatial light modulators experimentally. For 4-level, 8-level, and 16-level phase modulation, we achieved the bit error rate (BER) of 0.3%, 1.5% and 6.6% respectively. To further improve data storage density, an orthogonal reference encoding multiplexing method at the same position of medium is also proposed and validated experimentally. We increased the code rate of pure 3/16 amplitude encoding method from 0.5 up to 1.0 and 1.5 using 4-level and 8-level phase modulation respectively.

12 March 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Yong HuangYong Huang
Yong Huang
NZNan Zhang
Nan Zhang
QHQun Hao
Qun Hao
Optical coherence tomography (OCT) is a high-resolution non-invasive 3D imaging modality, which has been widely used for biomedical research and clinical studies. The presence of noise on OCT images is inevitable which will cause problems for post-image processing and diagnosis. The frame-averaging technique that acquires multiple OCT images at the same or adjacent locations can enhance the image quality significantly. Both conventional frame averaging methods and deep learning-based methods using averaged frames as ground truth have been reported. However, conventional averaging methods suffer from the limitation of long image acquisition time, while deep learning-based methods require complicated and tedious ground truth label preparation. In this work, we report a deep learning-based noise reduction method that does not require clean images as ground truth for model training. Three network structures, including Unet, super-resolution residual network (SRResNet), and our modified asymmetric convolution-SRResNet (AC-SRResNet), were trained and evaluated using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge preservation index (EPI) and computation time (CT). The effectiveness of these three trained models on OCT images of different samples and different systems was also investigated and confirmed. The SNR improvement for different sample images for L2-loss-trained Unet, SRResNet, and AC-SRResNet are 20.83 dB, 24.88 dB, and 22.19 dB, respectively. The SNR improvement for public images from different system for L1-loss-trained Unet, SRResNet, and AC-SRResNet are 19.36 dB, 20.11 dB, and 22.15 dB, respectively. AC-SRResNet and SRResNet demonstrate better denoising effect than Unet with longer computation time. AC-SRResNet demonstrates better edge preservation capability than SRResNet while Unet is close to AC-SRResNet. Eventually, we incorporated Unet, SRResNet, and AC-SRResNet into our graphic processing unit accelerated OCT imaging system for online noise reduction evaluation. Real-time noise reduction for OCT images with size of 512×512 pixels for Unet, SRResNet, and AC-SRResNet at 64 fps, 19 fps, and 17 fps were achieved respectively.

27 November 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
XLXiao Lin
Xiao Lin
Yong HuangYong Huang
Yong Huang
TSTsutomu Shimura
Tsutomu Shimura
RFRyushi Fujimura
Ryushi Fujimura
YTYoshito Tanaka
Yoshito Tanaka
XTXiaodi Tan
Xiaodi Tan
Fast non-interferometric phase retrieval is a very important technique for phase-encoded holographic data storage and other phase based applications due to its advantage of easy implementation, simple system setup, and robust noise tolerance. Here we present an iterative non-interferometric phase retrieval for 4-level phase encoded holographic data storage based on an iterative Fourier transform algorithm and known portion of the encoded data, which increases the storage code rate to two-times that of an amplitude based method. Only a single image at the Fourier plane of the beam is captured for the iterative reconstruction. Since beam intensity at the Fourier plane of the reconstructed beam is more concentrated than the reconstructed beam itself, the requirement of diffractive efficiency of the recording media is reduced, which will improve the dynamic range of recording media significantly. The phase retrieval only requires 10 iterations to achieve a less than 5% phase data error rate, which is successfully demonstrated by recording and reconstructing a test image data experimentally. We believe our method will further advance the holographic data storage technique in the era of big data.

1 July 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Yong HuangYong Huang
Yong Huang
XLXiaochen Li
Xiaochen Li
JLJunyu Liu
Junyu Liu
ZQZhengyu Qiao
Zhengyu Qiao
JCJingsi Chen
Jingsi Chen
Qun HaoQun Hao
Qun Hao
Optical coherence tomography (OCT) is a three-dimensional non-invasive high-resolution imaging modality that has been widely used for applications ranging from medical diagnosis to industrial inspection. Common OCT systems are equipped with limited field-of-view (FOV) in both the axial depth direction (a few millimeters) and lateral direction (a few centimeters), prohibiting their applications for samples with large and irregular surface profiles. Image stitching techniques exist but are often limited to at most 3 degrees-of-freedom (DOF) scanning. In this work, we propose a robotic-arm-assisted OCT system with 7 DOF for flexible large FOV 3D imaging. The system consists of a depth camera, a robotic arm and a miniature OCT probe with an integrated RGB camera. The depth camera is used to get the spatial information of targeted sample at large scale while the RGB camera is used to obtain the exact position of target to align the image probe. Eventually, the real-time 3D OCT imaging is used to resolve the relative pose of the probe to the sample and as a feedback for imaging pose optimization when necessary. Flexible probe pose manipulation is enabled by the 7 DOF robotic arm. We demonstrate a prototype system and present experimental results with flexible tens of times enlarged FOV for plastic tube, phantom human finger, and letter stamps. It is expected that robotic-arm-assisted flexible large FOV OCT imaging will benefit a wide range of biomedical, industrial and other scientific applications.

26 July 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
XLXiaochen Li
Xiaochen Li
Yong HuangYong Huang
Yong Huang
QHQun Hao
Qun Hao
Optical coherence tomography (OCT) is a promising real-time and non-invasive imaging technology widely utilized in biomedical and material inspection domains. However, limited field of view (FOV) in conventional OCT systems hampers their broader applicability. Here, we propose an automated system integrating a structured light camera and robotic arm for large-area OCT scanning. The system precisely detects tissue contours, automates scan path generation, and enables accurate scanning of expansive sample areas. The proposed system consists of a robotic arm, a three-dimensional (3D) structured light camera, and a customized portable OCT probe. The 3D structured light camera is employed to generate a precise 3D point cloud of the sample surface, enabling automatic planning of the scanning path for the robotic arm. Meanwhile, the OCT probe is mounted on the robotic arm, facilitating scanning of the sample along the predetermined path. Continuous OCT B-scans are acquired during the scanning process, facilitating the generation of high-resolution and large-area 3D OCT reconstructions of the sample. We conducted position error tests and presented examples of 3D macroscopic imaging of different samples, such as ex vivo kidney, skin and leaf blade. The robotic arm can accurately reach the planned positions with an average absolute error of approximately 0.16 mm. The findings demonstrate that the proposed system enables the acquisition of 3D OCT images covering an area exceeding 20 cm2, indicating wide-ranging potential for utilization in diverse domains such as biomedical, industrial, and agricultural fields.