Nikhil Paliwal

Nikhil Paliwal

Auto-generated profile, based on publicly available information

Nikhil Paliwal

University College London

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2016 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
CWChao Wang
Chao Wang
ZTZhongbin Tian
Zhongbin Tian
JLJian Liu
Jian Liu
LJLinkai Jing
Linkai Jing
NPNikhil Paliwal
Nikhil Paliwal
XYXinjian Yang
Xinjian Yang
The aim of this study was to quantify the effect of the new Low-profile Visualized Intraluminal Support (LVIS®D) device and the difference of fluid diverting effect compared with the Pipeline device and the Enterprise stent using computational fluid dynamics (CFD). In this research, we simulated three aneurysms constructed from 3D digital subtraction angiography (DSA). The Enterprise, LVIS and the Pipeline device were virtually conformed to fit into the vessel lumen and placed across the aneurysm orifice. Computational fluid dynamics analysis was performed to compare the hemodynamic differences such as WSS, Velocity and Pressure among these stents. Control referred to the unstented model, the percentage of hemodynamic changes were all compared to Control. A single LVIS stent caused more wall shear stress reduction than double Enterprise stents (39.96 vs. 30.51 %) and velocity (23.13 vs. 18.64 %). Significant reduction in wall shear stress (63.88 %) and velocity (46.05 %) was observed in the double-LVIS stents. A single Pipeline showed less reduction in WSS (51.08 %) and velocity (37.87 %) compared with double-LVIS stent. The double-Pipeline stents resulted in the most reduction in WSS (72.37 %) and velocity (54.26 %). Moreover, the pressure increased with minuscule extent after stenting, compared with the unstented model. This is the first study analyzing flow modifications associated with LVIS stents. We found that the LVIS stent has certain hemodynamic effects on cerebral aneurysms: a single LVIS stent caused more flow reductions than the double-Enterprise stent but less than a Pipeline device. Nevertheless, the double-LVIS stent resulted in a better flow diverting effect than a Pipeline device.

1 November 2018 in Neurosurgical Focus
Verified
Journal Article
Closed access
PDF file
NPNikhil Paliwal
Nikhil Paliwal
PJPrakhar Jaiswal
Prakhar Jaiswal
VTVincent M. Tutino
Vincent M. Tutino
HSHussain Shallwani
Hussain Shallwani
JDJason M. Davies
Jason M. Davies
HMHui Meng
Hui Meng
OBJECTIVE: Flow diverters (FDs) are designed to occlude intracranial aneurysms (IAs) while preserving flow to essential arteries. Incomplete occlusion exposes patients to risks of thromboembolic complications and rupture. A priori assessment of FD treatment outcome could enable treatment optimization leading to better outcomes. To that end, the authors applied image-based computational analysis to clinically FD-treated aneurysms to extract information regarding morphology, pre- and post-treatment hemodynamics, and FD-device characteristics and then used these parameters to train machine learning algorithms to predict 6-month clinical outcomes after FD treatment. METHODS: Data were retrospectively collected for 84 FD-treated sidewall aneurysms in 80 patients. Based on 6-month angiographic outcomes, IAs were classified as occluded (n = 63) or residual (incomplete occlusion, n = 21). For each case, the authors modeled FD deployment using a fast virtual stenting algorithm and hemodynamics using image-based computational fluid dynamics. Sixteen morphological, hemodynamic, and FD-based parameters were calculated for each aneurysm. Aneurysms were randomly assigned to a training or testing cohort in approximately a 3:1 ratio. The Student t-test and Mann-Whitney U-test were performed on data from the training cohort to identify significant parameters distinguishing the occluded from residual groups. Predictive models were trained using 4 types of supervised machine learning algorithms: logistic regression (LR), support vector machine (SVM; linear and Gaussian kernels), K-nearest neighbor, and neural network (NN). In the testing cohort, the authors compared outcome prediction by each model trained using all parameters versus only the significant parameters. RESULTS: The training cohort (n = 64) consisted of 48 occluded and 16 residual aneurysms and the testing cohort (n = 20) consisted of 15 occluded and 5 residual aneurysms. Significance tests yielded 2 morphological (ostium ratio and neck ratio) and 3 hemodynamic (pre-treatment inflow rate, post-treatment inflow rate, and post-treatment aneurysm averaged velocity) discriminants between the occluded (good-outcome) and the residual (bad-outcome) group. In both training and testing, all the models trained using all 16 parameters performed better than all the models trained using only the 5 significant parameters. Among the all-parameter models, NN (AUC = 0.967) performed the best during training, followed by LR and linear SVM (AUC = 0.941 and 0.914, respectively). During testing, NN and Gaussian-SVM models had the highest accuracy (90%) in predicting occlusion outcome. CONCLUSIONS: NN and Gaussian-SVM models incorporating all 16 morphological, hemodynamic, and FD-related parameters predicted 6-month occlusion outcome of FD treatment with 90% accuracy. More robust models using the computational workflow and machine learning could be trained on larger patient databases toward clinical use in patient-specific treatment planning and optimization.

6 September 2018 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
PBPhilipp Berg
Philipp Berg
SVSamuel Voß
Samuel Voß
SSSylvia Saalfeld
Sylvia Saalfeld
GJGábor Janiga
Gábor Janiga
ABAslak W. Bergersen
Aslak W. Bergersen
OBOliver Beuing
Oliver Beuing

4 April 2017 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Closed access
PDF file
QZQianqian Zhang
Qianqian Zhang
LJLinkai Jing
Linkai Jing
JLJian Liu
Jian Liu
KWKun Wang
Kun Wang
YZYing Zhang
Ying Zhang
XYXinjian Yang
Xinjian Yang
Background The recanalization of cerebral aneurysms after endovascular embolization (coiling or stent-assisted coiling) has been a matter of concern. Objective To systematically evaluate the predisposing factors for cerebral aneurysm recanalization using multidimensional analysis in a large patient cohort. Methods In 238 patients with 283 aneurysms, patient baseline characteristics, aneurysm morphological characteristics, treatment-related factors, and changes in flow hemodynamics after endovascular treatment (coiling or stent-assisted coiling) were compared between the recanalization and non-recanalization groups. Multivariate logistic regression analysis was performed to determine independent risk factors correlated with recanalization. Results 16 aneurysms treated by coiling recanalized, with a recurrence rate of 18.6%, and 24 recanalized in the lesions treated by stent-assisted coiling, with a recanalization rate of 12.2%. Large aneurysms (>10 mm, p=0.002) and a follow-up interval >1 year (p=0.027) were shown to be statistically significant between the recanalization and non-recanalization groups. For flow hemodynamic changes, three parameters (velocity on the neck plane, wall shear stress on the neck wall, and wall shear stress on the whole aneurysm) showed a relatively lower amplitude of decrease after endovascular treatment in the recanalization group. Interestingly, the velocity on the neck plane and wall shear stress on the neck wall may be elevated after treatment. Specifically, the reduction ratio (RR) of velocity on the neck plane showed significant difference between the groups in the multivariate analysis (p=0.013), and was considered an independent risk factor for recanalization. Conclusions The aneurysm size, follow-up interval, and flow hemodynamic changes, especially the RR of velocity on the neck plane, have important roles in aneurysm recanalization.

5 January 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
RDR.J. Damiano
R.J. Damiano
VTVincent M. Tutino
Vincent M. Tutino
NPN. Paliwal
N. Paliwal
DMD. Ma
D. Ma
JDJ.M. Davies
J.M. Davies
HMH. Meng
H. Meng
BACKGROUND AND PURPOSE: Locally compacting the mesh of a flow diverter by a dynamic push-pull technique can accelerate intracranial aneurysm healing. We asked how this deployment strategy compares with overlapping 2 flow diverters for aneurysmal flow reduction. MATERIALS AND METHODS: Using a high-fidelity virtual stent placement method, we simulated 3 flow-diverter strategies (single noncompacted, 2 overlapped, and single compacted) in 3 aneurysms (fusiform, large saccular, and medium saccular). Computational fluid dynamics analysis provided posttreatment hemodynamic parameters, including time-averaged inflow rate, aneurysm-averaged velocity, wall shear stress, total absolute circulation, and turnover time. We examined the relationship between the achieved degree of compaction and aneurysm orifice area. RESULTS: Flow-diverter compaction resulted in a compaction coverage of 57%, 47%, and 22% over the orifice of the fusiform, large, and medium saccular aneurysm, respectively. Compaction coverage increased linearly with orifice area. In the fusiform aneurysm, the single compacted flow diverter accomplished more aneurysmal flow reduction than the other 2 strategies, as indicated by all 5 hemodynamic parameters. In the 2 saccular aneurysms, the overlapped flow diverters achieved the most flow reduction, followed by the single compacted and the noncompacted flow diverter. CONCLUSIONS: Compacting a single flow diverter can outperform overlapping 2 flow diverters in aneurysmal flow reduction, provided that the compaction produces a mesh denser than 2 overlapped flow diverters and this denser mesh covers a sufficient portion of the aneurysm orifice area, for which we suggest a minimum of 50%. This strategy is most effective for aneurysms with large orifices, especially fusiform aneurysms.

1 May 2016 in World Neurosurgery
Verified
Journal Article
Closed access
LJLinkai Jing
Linkai Jing
JZJingru Zhong
Jingru Zhong
JLJian Liu
Jian Liu
XYXinjian Yang
Xinjian Yang
NPNikhil Paliwal
Nikhil Paliwal
YZYing Zhang
Ying Zhang