19 July 1993 in Physical Review Letters
We study the stability of small strangelets by employing a simple model of strange matter as a gas of noninteracting fermions confined in a bag. We solve the Dirac equation and populate the energy levels of the bag one quark at a time. We find that for system parameters such that strange matter is unbound in bulk, there may still exist strangelets with A<100 that are metastable. We cannot determine, however, whether the lifetime of these strangelets is sufficient to detect them in current accelerator experiments.
29 November 2005 in Physical Review Letters
Longitudinal compression of a velocity-tailored, intense neutralized beam at 300 keV, 25 mA has been demonstrated. The compression takes place in a 1–2 m drift section filled with plasma to provide space-charge neutralization. An induction cell produces a head-to-tail velocity ramp that longitudinally compresses the neutralized beam, enhancing the beam peak current by a factor of 50 and producing a pulse duration of about 3 ns. This measurement has been confirmed independently with two different diagnostic systems.
31 May 1999 in Physical Review Letters
We report on the autoresonant (nonlinear phase locking) manipulation of the diocotron mode in a non-neutral plasma. Autoresonance is a very general phenomena in driven nonlinear oscillator and wave systems, and allows us to control the amplitude of a nonlinear wave without the use of feedback. These are the first controlled laboratory studies of autoresonance in a collective plasma system.
1 October 2018 in Review of Scientific Instruments
We present a device for controlled injection of a variety of materials in powder form. The system implements four independent feeder units, arranged to share a single vertical drop tube. Each unit consists of a 80 ml reservoir, coupled to a horizontal linear trough, where a layer of powder is advanced by piezo-electric agitation at a speed proportional to the applied voltage, until it falls into a drop tube. The dropper has been tested with a number of impurities of low (B, BN, C), intermediate (Si, SiC), and high Z (Sn) and a variety of microscopic structures (flakes, spheres, rocks) and sizes (5-200 μm). For low Z materials, drop rates ∼2-200 mg/s have been obtained showing good repeatability and uniformity. A calibrated light-emitting diode (LED)-based flowmeter allows measuring and monitoring the drop rate during operation. The fast time-response of the four feeders allows combination of steady and pulsed injections, providing a flexible tool for controlled-dose, real-time impurity injection in fusion plasmas.
23 April 2004 in Physics of Plasmas
Experimental techniques to provide active neutralization for space-charge-dominated beams as well as to prevent uncontrolled ion beam neutralization by stray electrons have been demonstrated. Neutralization is provided by a localized plasma injected from a cathode arc source. Unwanted secondary electrons produced at the wall by halo particle impact are suppressed using a radial mesh liner that is positively biased inside a beam drift tube. Measurements of current transmission, beam spot size as a function of axial position, beam energy, and plasma source conditions are presented along with detailed comparisons with theory.
8 April 2016 in Nuclear Fusion
A newly installed Lithium Granule Injector (LGI) was used to pace edge localized modes (ELM) in DIII-D. ELM pacing efficiency was studied injecting lithium granules of nominal diameter 0.3–0.9 mm, speed of 50–120 m s−1 and average injection rates up to 100 Hz for 0.9 mm granules and up to 700 Hz for 0.3 mm granules. The efficiency of ELM triggering was found to depend strongly on size of the injected granules, with triggering efficiency close to 100% obtained with 0.9 mm diameter granules, lower with smaller sizes, and weakly depending on granule velocity. Robust ELM pacing was demonstrated in ITER-like plasmas for the entire shot length, at ELM frequencies 3–5 times larger than the ‘natural’ ELM frequency observed in reference discharges. Within the range of ELM frequencies obtained, the peak ELM heat flux at the outer strike point was reduced with increasing pacing frequency. The peak heat flux reduction at the inner strike point appears to saturate at high pacing frequency. Lithium was found in the plasma core, with a concurrent reduction of metallic impurities and carbon. Overall, high frequency ELM pacing using the lithium granule injection appears to be compatible with both H-mode energy confinement and attractive H-mode pedestal characteristics, but further assessment is needed to determine whether the projected heat flux reduction required for ITER can be met.