Amit Kumar Thakur

Amit Kumar Thakur

Auto-generated profile, based on publicly available information

Amit Kumar Thakur

Department of Electrical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, India

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2021 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
VPVijay Babu Electronics Pamshetti
Vijay Babu Electronics Pamshetti
Shailendra SinghShailendra Singh
Shailendra Singh
ATAmit Kumar Thakur
Amit Kumar Thakur
SSS. P. Singh
S. P. Singh
The conservation voltage reduction (CVR) technique is a well-established technique for peak demand reduction and energy savings in the presence of voltage-sensitive loads. However, intermittent and uncertain nature of renewable energy sources such as photovoltaic generation may produce some operational issues under real-time CVR operation, which results in major problems such as undervoltage as well as increase in power losses in an active distribution network. Advanced power-electronics-based devices such as inverter-based distributed generators (IDGs) and soft open point (SOP) devices emerge as potential solutions for the aforementioned issues by providing the volt-ampere reactive (VAR) support. However, an efficient CVR methodology is much needed for proper coordination of multiple traditional volt/VAR control devices and advanced power-electronics-based devices. Therefore, this article introduces a multistage coordinated CVR methodology incorporating IDG and SOP devices for offline (i.e., day-ahead scheduling) and online (i.e., real-time dispatch) studies. For day-ahead scheduling, stochastic CVR formulation has been developed considering intermittency and uncertainties in power loads and generations. In contrast, online simulations have been performed in two stages for near-real-time operation using an inner-day rolling control model based on model-predictive control and real-time control through modified volt/VAR droop (VVD) control by optimal VVD curve selection. To validate the proposed scheme, a real-time cosimulation platform using a real-time digital simulator and a MATLAB-GAMS interface has been built. The efficacy of the proposed method has been validated on various case studies and also tested on sudden external disturbances such as sudden cloud transient, cloud cover, and substation voltage changes. Furthermore, the robustness of the proposed method has also been checked under faulty conditions. The test results demonstrate the significance of the proposed methodology on voltage violation mitigation, energy loss, energy consumption minimization, and service restoration.

21 November 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
VPVijay Babu Electronics Pamshetti
Vijay Babu Electronics Pamshetti
Shailendra SinghShailendra Singh
Shailendra Singh
ATA K Thakur
A K Thakur
SSS P Singh
S P Singh
TBT Sudhakar Babu
T Sudhakar Babu
GKG Hari Krishna
G Hari Krishna
In this paper, optimal cooperative operational planning of distributed energy resources (DER) in an active distribution network (ADN) with soft open points (SOP) has been investigated. To do so, a new two-layer coordinated optimization framework ADN has been proposed considering SOP. In the upper layer, the location and sizing of the DERs and SOPs has been optimised. While inner layer executes simultaneous optimal functioning of volt/var control (VVC) devices, remote controlled switches (RCS), DERs, and SOPs. The main objective of proposed methodology is to reduce total investment cost of DERs and SOPs as well as operating costs of the system over the planning horizon. Besides, objective function considers the cost of energy not served (ENS), the cost of substation-purchased electricity, and the cost of carbon emissions. Meanwhile, a stochastic module has been employed to address high-level uncertainties associated to renewables and load demands. Besides, the effects of distribution network reconfiguration (DNR) and conservation voltage reduction (CVR) have been taken into account. For various instances, the suggested framework was implemented on an IEEE 119-bus distribution system and solved using a proposed hybrid optimization solver. The efficacy of proposed DER with SOP methodology has been validated on various cases and also tested on sudden external disturbances such as under voltage and over voltage problem conditions. When compared to standard planning schemes, the test results show that it is beneficial in boosting system efficiency, increasing reliability, and lowering the carbon footprint of distribution systems.

25 May 2020 in IEEE Systems Journal
Verified
Journal Article
Closed access
Shailendra SinghShailendra Singh
Shailendra Singh
VPVijay Babu Electronics Pamshetti
Vijay Babu Electronics Pamshetti
ATAmit Kumar Thakur
Amit Kumar Thakur
SSS. P. Singh
S. P. Singh
This article investigates the need of coordinated operation of multiple voltage regulation devices under different time scales to enhance energy efficiency via conservation voltage reduction (CVR) in distribution networks in the presence of high photovoltaic (PV) penetration. A multistage multiobjective Volt/VAR control strategy for smart grid-enabled CVR has been proposed. In order to maximize the benefits of CVR, the method has been implemented in multiple stages of slow and fast time scale control periods for planning and real-time operations, respectively. The stochastic multiobjective Volt/VAR optimization considering uncertainty and forecasting errors has been formulated for the planning stage. However, in real-time operation, an adaptive Volt/VAR droop-controlled approach has been proposed for fast time controllers to mitigate voltage fluctuations during the sudden change in PV active power output. Besides, the economic impact of CVR in terms of cost savings has been investigated. The proposed control algorithms have been validated in real-time co-simulation platform. The simulated results demonstrate a higher reduction in peak demand, daily energy demand, and system losses. Further, a higher reduction in power purchase cost has been achieved in the presence of PV system with CVR in comparison to PV alone. Moreover, the proposed control algorithms work well in real-time operation under intermittency in PV power output also.

9 February 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Shailendra SinghShailendra Singh
Shailendra Singh
VPVijay Babu Electronics Pamshetti
Vijay Babu Electronics Pamshetti
ATAmit Kumar Thakur
Amit Kumar Thakur
SSS. P. Singh
S. P. Singh
HGHoay Beng Gooi
Hoay Beng Gooi
Large-scale installations of utility and customer's owned distributed technologies at low and medium voltage networks have drawn the distribution system operator's attention towards enhancing energy efficiency and economics of distribution grids. It can be achieved by deploying suitable energy-saving programs and unlocking the benefits of networked community microgrids (N-CMGs). In this context, the paper introduces an integrated methodology by enabling the volt/voltage optimization and demand response management scheme in the presence of N-CMGs that leverage distributed energy resources, flexible loads, and a smart energy management system. The stochastic objective function has been formulated regarding net profit value maximization in the presence of N-CMG assets. Further, efficient cascaded droop (Volt/VAR, Volt/Watt) control algorithms have been developed for real-time control of N-CMGs operations under unexpected transient conditions. The simulated outcomes authenticate that the proposed integrated method maximized the net profit values in terms of reduced purchased electricity cost and improved energy efficiency. Moreover, the developed real-time cascaded droop controller for N-CMGs successfully handles the unprecedented event's impact on system security during real-time operation.


8 June 2020 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
DSDevesh Shukla
Devesh Shukla
SSShiv P. Singh
Shiv P. Singh
ATAmit Kumar Thakur
Amit Kumar Thakur
SMSoumya R. Mohanty
Soumya R. Mohanty
Assessment and enhancement of transmission network capability have been one of the prime interests of power system monitoring, operation and control. Conventionally, the issue of available transfer capability (ATC) assessment has been tackled considering the transmission and distribution networks as segregated entities because they had little or no influence on each other's performance owing to the unidirectional flow of power from the transmission to distribution networks. Now, with increasing interest in smart transmission and distribution in amalgamation with a paradigm shift in sources of generation from centralised to decentralised even at distribution levels mandating the analysis of power grid while inculcating both the hierarchies simultaneously. In this study, a platform for quasi‐static operation of power transmission and distribution networks, employing a multi‐agent based system has been developed. The developed multi‐agent systembased system has been utilised for assessment of ATC considering active distribution network (ADN) whereby Modified IEEE 24 bus system at transmission and Modified IEEE 123 node system at distribution level has been considered as a test system. It has been observed that the presence of ADN considerably affects the ATC of the system.