Simone Gaffling

Simone Gaffling

Auto-generated profile, based on publicly available information

Simone Gaffling

Chimaera GmbH, Erlangen, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in The Ocular Surface
Verified
Journal Article
Closed access
MAMohammad Javed Ali
Mohammad Javed Ali
MZMaximilian Zetzsche
Maximilian Zetzsche
MSMichael Scholz
Michael Scholz
DHDieter Hahn
Dieter Hahn
SGSimone Gaffling
Simone Gaffling
Friedrich  PaulsenFriedrich Paulsen
Friedrich Paulsen

29 October 2021 in IEEE Access
Verified
Journal Article
Open access
OLOleg Lobachev
Oleg Lobachev
TFTakuya Funatomi
Takuya Funatomi
APAlexander Pfaffenroth
Alexander Pfaffenroth
RFReinhold Förster
Reinhold Förster
LKLars Knudsen
Lars Knudsen
RGRoman Grothausmann
Roman Grothausmann
Registration of histological serial sections is a challenging task. Serial sections exhibit distortions and damage from sectioning. Missing information on how the tissue looked before cutting makes a realistic validation of 2D registrations extremely difficult. This work proposes methods for ground-truth-based evaluation of registrations. Firstly, we present a methodology to generate test data for registrations. We distort an innately registered image stack in the manner similar to the cutting distortion of serial sections. Test cases are generated from existing 3D data sets, thus the ground truth is known. Secondly, our test case generation premises evaluation of the registrations with known ground truths. Our methodology for such an evaluation technique distinguishes this work from other approaches. Both under- and over-registration become evident in our evaluations. We also survey existing validation efforts. We present a full-series evaluation across six different registration methods applied to our distorted 3D data sets of animal lungs. Our distorted and ground truth data sets are made publicly available.

30 April 2026 in Acta Biomaterialia
Verified
Journal Article
Open access
ONOskar Neumann
Oskar Neumann
RRRahul Gopalan Ramachandran
Rahul Gopalan Ramachandran
HSHarsh Vardhan Surana
Harsh Vardhan Surana
Friedrich  PaulsenFriedrich Paulsen
Friedrich Paulsen
MSMichael Scholz
Michael Scholz
SBSilvia Budday
Silvia Budday
The ultrasoft nature and intricate geometry of the 'butterfly-shaped' spinal cord gray matter, surrounded by white matter, pose major challenges for experimental and computational characterization of tissue mechanics. With growing interest in modeling spinal cord injury, disease, and regeneration, reliable mechanical data are increasingly needed. To meet this demand, we developed a multimodal characterization pipeline, combining mesoscale spherical indentation of gray and white matter, macroscale rheometer-based compression-tension tests, nonlinear continuum mechanics modeling, and inverse finite element simulations, using Hertzian, neo-Hookean, and Ogden constitutive laws. Both testing modalities were applied sequentially on samples extracted along the cranio-caudal axis of porcine spinal cords to assess regional variations in mechanical properties. Compared with Hertzian and neo-Hookean models, Ogden models more accurately captured the nonlinear material response. For comparable loading rates, shear moduli from mesoscale indentation are consistent with those from macroscale large-strain testing, demonstrating the robustness of the multimodal approach. Based on these observations, we demonstrate the effectiveness of identifying nonlinear material parameters for spinal cord gray and white matter tissue through the simultaneous integration of indentation and large-strain data. Like this, we for the first time include information on both, tissue-type-specific properties as well as large-strain nonlinear effects. Our results demonstrate that a multimodal characterization pipeline can yield a more robust and representative material parameters with important implications for advanced treatment strategies for spinal cord injuries and disease. Statement of Significance: In the growing body of research on the mechanical characterization of brain and spinal cord tissue, discrepancies between measured properties obtained from different testing modalities remain a major challenge. In this study, we use two complementary testing methods - spherical indentation and large-strain compression-tension loading - applied to the same samples. We demonstrate that when the experimental data are analyzed using nonlinear material modeling and finite element simulations, the results from both methods agree well. We for the first time integrate both indentation and large-strain testing data to identify reliable individual material parameters for spinal cord gray and white matter tissue. Our results highlight the robustness of the presented multimodal characterization pipeline for central nervous system tissue.