Structures designed in accordance with even the most modern buildings codes are expected to sustain damage during a severe earthquake; however; these structures are expected to protect the lives of the occupants. Damage to the structure can require expensive repairs; significant business downtime; and in some cases building demolition. If damage occurs to many structures within a city or region; the regional and national economy may be severely disrupted. To address these shortcomings with current seismic lateral force resisting systems and to work towards more resilient; sustainable cities; a new class of seismic lateral force resisting systems that sustains little or no damage under severe earthquakes has been developed. These new seismic lateral force resisting systems reduce or prevent structural damage to nonreplaceable structural elements by softening the structural response elastically through gap opening mechanisms. To dissipate seismic energy; friction elements or replaceable yielding energy dissipation elements are also included. Post-tensioning is often used as a part of these systems to return the structure to a plumb; upright position (self-center) after the earthquake has passed. This paper summarizes the state-of-the art for self-centering seismic lateral force resisting systems and outlines current research challenges for these systems.
Conventional concentrically-braced frame (CBF) systems have limited drift capacity before brace buckling and related damage leads to deterioration in strength and stiffness. Under the NSF funded NEESR-SG research program, a new type of CBF is being developed with increased drift capacity before damage and decreased permanent drift under seismic loading. These self-centering CBF (SC-CBF) systems are intended to provide significant non-linear drift capacity while limiting damage and residual drift, and are motivated by the goal of minimizing structural damage under seismic loading. At low levels of lateral load, the response of an SC-CBF is similar to that of a conventional CBF. At higher levels of lateral load, the fundamental lateral load behavior of the SC-CBF system is rocking about the base of the compression column, which occurs when the column under tension from overturning moment decompresses and uplifts at the foundation. To control the uplift, high strength post-tensioning (PT) bars, oriented vertically over the height of the SC-CBF, prestress the frame to the foundation. The SC-CBF is designed to decompress at the base at a selected level of lateral loading, initiating a rigid-body rotation (rocking) of the frame. The PT bars provide a restoring force to return the CBF to the foundation (to self-center the CBF). The rocking response substantially influences the member forces that develop in the frame members (beams, columns, and braces) and induces deformation and eventually yielding of the PT bars. To minimize structural damage before PT bar yield, the frame members are designed to resist the internal forces that develop at PT yield. The paper presents the results of an analytical study of SC-CBFs. Dynamic analysis results demonstrate the expected drift capacity and self-centering behavior of the system. Modal decomposition of these analysis results shows that the first mode response is effectively limited by the rocking behavior; however, the higher modes are also excited by the rocking response. Based on these analysis results an improved design method is presented that accounts for the higher mode contributions to the member forces of the SC-CBF.
In the current study, the performances of some decision tree (DT) techniques are evaluated for postearthquake soil liquefaction assessment. A database containing 620 records of seismic parameters and soil properties is used in this study. Three decision tree techniques are used here in two different ways, considering statistical and engineering points of view, to develop decision rules. The DT results are compared to the logistic regression (LR) model. The results of this study indicate that the DTs not only successfully predict liquefaction but they can also outperform the LR model. The best DT models are interpreted and evaluated based on an engineering point of view.
Conventional concentrically-braced frame (CBF) systems have limited drift capacity before brace buckling and related damage leads to deterioration in strength and stiffness. A new type of CBF is being developed which has greater drift capacity before damage and which develops less permanent (residual) drift under seismic loading. This self-centering CBF (SC-CBF) system is motivated by the goal of minimizing structural damage under seismic loading and is intended to provide significant non-linear drift capacity while limiting damage and residual drift. The fundamental lateral load behavior of the SC-CBF system is rocking on its base, which occurs when the column under tension from overturning moment decompresses and uplifts from its support. The SC-CBF is designed to decompress at the base at a selected level of lateral loading, initiating a rigid-body rotation (rocking) of the frame. Vertically-aligned post-tensioning (PT) steel resists this uplift and provides a restoring force to return the SC-CBF to its support (to re-center the system). Experimental results show that SC-CBFs can be designed to sustain no significant structural damage under the design basis earthquake and only minor structural damage under the maximum considered earthquake.