James Michael Ricles

James Michael Ricles

Auto-generated profile, based on publicly available information

James Michael Ricles

Department of Civil and Environmental Engineering Lehigh University Bethlehem Pennsylvania USA

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2001 in Journal of Structural Engineering
Verified
Journal Article
Closed access
JRJames M. Ricles
James M. Ricles
RSRichard Sause
Richard Sause
MGMaria Garlock
Maria Garlock
CZChen Zhao
Chen Zhao
Steel moment-resisting frames (MRFs) with posttensioned connections are constructed by posttensioning beams to columns using high strength strands. Top and seat angles are added to provide energy dissipation and redundancy under seismic loading. This new type of connection has several advantages, including the following: (1) field welding is not required; (2) the connection stiffness is similar to that of a welded connection; (3) the connection is self-centering; and (4) significant damage to the MRF is confined to the angles of the connection. An analytical model based on fiber elements was developed for these connections. Experimental test results were used to calibrate the model. The model was used for inelastic static analyses of interior connection subassembages as well as dynamic time history analyses of a six-story steel MRF. A self-centering capability and adequate stiffness, strength, and ductility were observed in the results of these analyses. Time history analysis results show that the seismic performance of a posttensioned steel MRF subject to the earthquake records studied here exceeds the performance of an MRF with typical welded connections subject to the same earthquake records.

1 November 2001 in Journal of Composites for Construction
Verified
Journal Article
Closed access
SPStephen Pessiki
Stephen Pessiki
KHKent A. Harries
Kent A. Harries
JKJustin T. Kestner
Justin T. Kestner
RSRichard Sause
Richard Sause
JRJames M. Ricles
James M. Ricles
This paper presents the results of an experimental investigation of the axial behavior of small-scale circular and square plain concrete specimens and large-scale circular and square reinforced concrete columns confined with fiber reinforced polymer (FRP) composite jackets, subject to monotonic, concentric axial loads. Improvements in the axial load-carrying and deformation capacities of FRP jacketed concrete members over unjacketed members are reported. Factors influencing the axial stress-strain behavior of FRP confined concrete, such as transverse dilation and effectively confined regions and their relationship to jacket properties, are identified and discussed. Factors necessary to calibrate in situ jacket behavior and reported or measured FRP material properties are proposed and their interrelationships discussed.

1 September 2007 in Journal of Structural Engineering
Verified
Journal Article
Closed access
LFLarry A. Fahnestock
Larry A. Fahnestock
JRJames M. Ricles
James M. Ricles
RSRichard Sause
Richard Sause
As buckling-restrained braced frames (BRBFs) have been used increasingly in the United States, the need for knowledge about BRBF behavior has grown. In particular, large-scale experimental evaluations of BRBFs are necessary to demonstrate the seismic performance of the system. Although tests of buckling-restrained braces (BRBs) have demonstrated their ability to withstand significant ductility demands, large-scale BRBF tests have exhibited poor performance at story drifts between 0.02 and 0.025 rad . These tests indicate that the large stiffness of the typical beam-column-brace connection detail leads to large flexural demands that cause undesirable failure modes. As part of a research program composed of numerical and experimental simulations, a large-scale BRBF with improved connection details was tested at the ATLSS Center, Lehigh University. During multiple earthquake simulations, which were conducted using a hybrid pseudodynamic testing method, the test frame sustained story drifts of close to 0.05 r...

1 July 2002 in Journal of Structural Engineering
Verified
Journal Article
Closed access
JRJ. M. Ricles
J. M. Ricles
RSR. Sause
R. Sause
SPS. W. Peng
S. W. Peng
LLL. W. Lu
L. W. Lu
Nine large-scale subassembly tests were conducted to investigate the behavior of an innovative posttensioned wide flange beam-to-column connection for steel moment resisting frames subjected to seismic loading conditions. The connection includes top and seat angles bolted to the beam and column. Strands are placed along the length of the beam, passing through the column and posttensioned to provide a precompression of the beam against the column. The parameters investigated in the study include the angle thickness, angle gage length, beam flange reinforcing plates, connection shim plates, and posttensioning force. The test results demonstrate that posttensioned connections provide excellent elastic stiffness, strength, and ductility under cyclic loading, with energy dissipation occurring primarily in the angles. The connection initial elastic stiffness is comparable to that of a fully restrained welded connection. In addition, the connection has essentially no residual deformation following several cycles...

1 March 2005 in Journal of Structural Engineering
Verified
Journal Article
Closed access
MGMaria Garlock
Maria Garlock
JRJames M. Ricles
James M. Ricles
RSRichard Sause
Richard Sause
Six full-scale interior connection subassemblies of posttensioned wide flange beam-to-column moment connections were subjected to inelastic cyclic loading up to 4% story drift to simulate earthquake loading effects. Bolted top and seat angles are used in the connection, along with posttensioned high strength strands that run parallel to the beam. These strands compress the beam flanges against the column flange to develop the resisting moment to service loading and to provide a restoring force that returns the structure to its initial position following an earthquake. The parameters studied in these experiments were the initial posttensioning force, the number of posttensioning strands, and the length of the reinforcing plates. The experimental results demonstrate that the posttensioned connection possesses good energy dissipation and ductility. Under drift levels of 4%, the beams and columns remain elastic, while only the top and seat angles are damaged and dissipate energy. The lack of damage to the bea...

1 April 2005 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PRP. Rojas
P. Rojas
JRJ. M. Ricles
J. M. Ricles
RSR. Sause
R. Sause
A post-tensioned friction damped connection (PFDC) for earthquake resistant steel moment resisting frames (MRFs) is introduced. The connection includes friction devices on the beam flanges with post-tensioned high strength strands running parallel to the beam. The connection minimizes inelastic deformation to the components of the connection as well as the beams and columns, and requires no field welding. Inelastic analyses were performed on a six-story, four-bay steel MRF with PFDCs to study its response to strong ground motions. The PFDC–MRF was designed using a performance based design approach. Results show the MRF with PFDCs has good energy dissipation, self-centering capability, and strength. Variability in the maximum friction forces that develop in the friction devices was determined not to have a significant effect on the MRF performance. The analyses indicate that the seismic performance of a MRF with PFDCs can exceed that of a MRF with conventional moment resisting connections.