In this work, we address the task of few-shot medical image segmentation (MIS) with a novel proposed framework based on the learning registration to learn segmentation (LRLS) paradigm. To cope with the limitations of lack of authenticity, diversity, and robustness in the existing LRLS frameworks, we propose the better registration better segmentation (BRBS) framework with three main contributions that are experimentally shown to have substantial practical merit. First, we improve the authenticity in the registration-based generation program and propose the knowledge consistency constraint strategy that constrains the registration network to learn according to the domain knowledge. It brings the semantic-aligned and topology-preserved registration, thus allowing the generation program to output new data with great space and style authenticity. Second, we deeply studied the diversity of the generation process and propose the space-style sampling program, which introduces the modeling of the transformation path of style and space change between few atlases and numerous unlabeled images into the generation program. Therefore, the sampling on the transformation paths provides much more diverse space and style features to the generated data effectively improving the diversity. Third, we first highlight the robustness in the learning of segmentation in the LRLS paradigm and propose the mix misalignment regularization, which simulates the misalignment distortion and constrains the network to reduce the fitting degree of misaligned regions. Therefore, it builds regularization for these regions improving the robustness of segmentation learning. Without any bells and whistles, our approach achieves a new state-of-the-art performance in few-shot MIS on two challenging tasks that outperform the existing LRLS-based few-shot methods. We believe that this novel and effective framework will provide a powerful few-shot benchmark for the field of medical image and efficiently reduce the costs of medical image research. All of our code will be made publicly available online.
29 July 2010 in IEEE Transactions on Image Processing
The derivation of moment invariants has been extensively investigated in the past decades. In this paper, we construct a set of invariants derived from Zernike moments which is simultaneously invariant to similarity transformation and to convolution with circularly symmetric point spread function (PSF). Two main contributions are provided: the theoretical framework for deriving the Zernike moments of a blurred image and the way to construct the combined geometric-blur invariants. The performance of the proposed descriptors is evaluated with various PSFs and similarity transformations. The comparison of the proposed method with the existing ones is also provided in terms of pattern recognition accuracy, template matching and robustness to noise. Experimental results show that the proposed descriptors perform on the overall better.
29 November 2010 in IEEE Transactions on Medical Imaging
Prostate segmentation in 3-D transrectal ultrasound images is an important step in the definition of the intra-operative planning of high intensity focused ultrasound (HIFU) therapy. This paper presents two main approaches for the semi-automatic methods based on discrete dynamic contour and optimal surface detection. They operate in 3-D and require a minimal user interaction. They are considered both alone or sequentially combined, with and without postregularization, and applied on anisotropic and isotropic volumes. Their performance, using different metrics, has been evaluated on a set of 28 3-D images by comparison with two expert delineations. For the most efficient algorithm, the symmetric average surface distance was found to be 0.77 mm.
24 August 2022 in IEEE Journal of Biomedical and Health Informatics
4D cone-beam computed tomography (CBCT) is an important imaging modality in image-guided radiation therapy to address the motion-induced artifacts caused by organ movements during the respiratory process. However, due to the extremely sparse projection data for each temporal phase, 4D CBCT reconstructions will suffer from severe streaking artifacts. Therefore, to tackle the streak artifacts and provide high-quality images, we proposed a framework termed Prior-Regularized Iterative Optimization Reconstruction (PRIOR) for 4D CBCT. The PRIOR framework combines the physics-based model and data-driven method simultaneously, with powerful feature extracting capacity, significantly promoting the image quality compared to single model-based or deep learning-based methods. Besides, we designed a specialized deep learning model named PRIOR-Net, which can effectively excavate the static information in the prior image reconstructed from the fully-sampled projections at the encoding stage to improve the reconstruction performance for individual phase-resolved images. Both the simulated and clinical 4D CBCT datasets were performed to evaluate the performance of the PRIOR-Net and the PRIOR framework. Compared with the advanced 4D CBCT reconstruction methods, the proposed methods achieve promising results quantitatively and qualitatively in streak artifact suppression, soft tissue restoration, and tiny detail preservation.
8 March 2022 in IEEE Journal of Biomedical and Health Informatics
Accurate and robust cephalometric image analysis plays an essential role in orthodontic diagnosis, treatment assessment and surgical planning. This paper proposes a novel landmark localization method for cephalometric analysis using multiscale image patch-based graph convolutional networks. In detail, image patches with the same size are hierarchically sampled from the Gaussian pyramid to well preserve multiscale context information. We combine local appearance and shape information into spatialized features with an attention module to enrich node representations in graph. The spatial relationships of landmarks are built with the incorporation of three-layer graph convolutional networks, and multiple landmarks are simultaneously updated and moved toward the targets in a cascaded coarse-to-fine process. Quantitative results obtained on publicly available cephalometric X-ray images have exhibited superior performance compared with other state-of-the-art methods in terms of mean radial error and successful detection rate within various precision ranges. Our approach performs significantly better especially in the clinically accepted range of 2 mm and this makes it suitable in cephalometric analysis and orthognathic surgery.
30 August 2023 in IEEE Transactions on Instrumentation and Measurement
Orthopedic spine disease is one of the most common diseases in the clinic. The diagnosis of spinal orthopedic injury is an important basis for the treatment of spinal orthopedic diseases. Due to the complexity of the spine structure, doctors usually need to rely on orthopedic CT image data for accurate diagnosis. In some cases, such as poor areas or in emergency situations, it is difficult for doctors to make accurate diagnoses using only 2D x-ray images due to lack of 3D imaging equipment or time crunch. Therefore, an approach based on 2D x-ray images is needed to solve this problem. In this paper, a novel 3D spine reconstruction technique based on 2D orthogonal x-ray images (3DSRNet) is designed. 3DSRNet uses a generative adversarial network architecture and novel modules to make 3D spine reconstruction more accurate and efficient. Spine reconstruction CNN-transformer framework (SRCT) is employed to effectively integrate local bone surface information and long-range relation spinal structure information. Spine reconstruction texture framework (SRTE) is used to extract spine texture features to enhance the effect of pixel-level reconstruction. Experiments show that 3DSRNet achieves excellent 3D spine reconstruction results on multiple metrics including PSNR (45.4666 dB), SSIM (0.8850), CS (0.7662), MAE (23.6696), MSE (9016.1044), and LPIPS (0.0768).