Qian Xu

Qian Xu

Auto-generated profile, based on publicly available information

Qian Xu

National Institute of Metrology, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZJZhengsen Jia
Zhengsen Jia
YWYuzhuo Wang
Yuzhuo Wang
JDJie Ding
Jie Ding
QXQian Xu
Qian Xu
YZYadongyang Zhu
Yadongyang Zhu
This paper introduces an FPGA-based time-to-digital converter with an online dual-chain calibration method to address time resolution and linearity issues arising from the non-uniformity of FPGA internal delay elements. The aim is to enhance the stability and accuracy of time-to-digital converters under varying environmental conditions. We employ an external high-precision clock to generate start-stop calibration signals for real-time monitoring of signal propagation time changes within FPGA components. Two identical delay chains in the time-to-digital converter are managed by a Finite State Machine to switch their roles, ensuring continuous data acquisition and online calibration. Experimental results show that the proposed time-to-digital converter significantly outperforms traditional time interval counter in terms of time linearity, maximum integral nonlinearity, and differential nonlinearity. Within a temperature range of 20°C to 80°C, post-online temperature calibration maintains the root mean square of the TDC below 20 ps, substantially improving performance across different temperature conditions.

25 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QXQian Xu
Qian Xu
ZJZhengsen Jia
Zhengsen Jia
YZYue Zhang
Yue Zhang
YWYuzhuo Wang
Yuzhuo Wang
AZAimin Zhang
Aimin Zhang
By considering the observation samples of a hydrogen maser relative to an optical clock with time-varying variances, this paper proposes an optimized predictor based on the finite impulse response (FIR) to improve the predictability of hydrogen masers. The design idea and rationality of the predictor were characterized from a theoretical viewpoint, showing its potential predictability for missing partial measurement data or unequal interval measurement data. The prediction results for simulated hydrogen masers reveal its comparable predictability with least squares method (LS). As proof of concept, it was applied to the actual data of typical hydrogen maser relative to a 87 Sr optical lattice clock developed by the National Institute of Metrology (NIM). Compared with the LS, the prediction error after 7 days obtained by the proposed method is ~40 ps smaller than LS.

4 March 2026 in GPS Solutions
Verified
Journal Article
Closed access
PDF file
QHQianyi Hu
Qianyi Hu
YCYu Chen
Yu Chen
QXQian Xu
Qian Xu
FWFangmin Wang
Fangmin Wang
LDLijun Du
Lijun Du
YWYuzhuo Wang
Yuzhuo Wang