Yuzhuo Wang

Dr. Yuzhuo Wang

National Institute of Metrology
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2021 in Metrologia
Verified
Journal Article
Closed access
YLYige Lin
Yige Lin
QWQiang Wang
Qiang Wang
FMFei Meng
Fei Meng
SCShiying Cao
Shiying Cao
YWYuzhuo Wang
Yuzhuo Wang
ZFZhanjun Fang
Zhanjun Fang
We report the 87 Sr optical lattice clock at NIM with a clock laser referenced to a 30 cm ULE cavity. Several improvements, such as the atomic temperature and density, the lattice laser frequency stabilization, the fiber noise cancellation, etc, have been made since its first evaluation in 2015. Its systematic frequency shifts are carefully evaluated with a total relative uncertainty of 2.9 × 10 −17 . The measured absolute frequency is 429 228 004 229 873.07(0.13) Hz with a relative uncertainty of 3.1 × 10 −16 , with reference to the ensemble of primary and secondary frequency standards published in the Circular T bulletin by BIPM through a satellite link.

31 January 2022 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
JCJian Cao
Jian Cao
JYJinbo Yuan
Jinbo Yuan
SWShaomao Wang
Shaomao Wang
PZPing Zhang
Ping Zhang
YYYi Yuan
Yi Yuan
XHXueren Huang
Xueren Huang
We report a robust, compact, and transportable optical clock (TOC-729-2) based on a trapped single 40Ca+ ion with a systematic uncertainty of 1.1×10−17 , which is limited by the black-body radiation shift uncertainty at room temperature. By comparing it with the previous transportable optical clock (TOC-729-1) similar but completely independent, the instability was measured to be better than 1.2×10−14/τ . Benefiting from the modular and integrated design, this TOC was constructed in a volume of ∼0.33 m3 excluding the controlling electronics in 19-in. racks. After being moved ∼1200 km away by express delivery, the single-ion signal was restored within 24 h. With the TOC uptime of 92% in 35-day period, the absolute frequency of the 729 nm transition of 40Ca+ was measured using a satellite link to International Atomic Time (TAI) to provide traceability to the SI second, and the result is 411 042 129 776 400.15(22) Hz, corresponding to a relative uncertainty of 5.3×10−16 .

14 September 2022 in Metrologia
Verified
Journal Article
Closed access
LZLin Zhu
Lin Zhu
YLYige Lin
Yige Lin
YWYuzhuo Wang
Yuzhuo Wang
ZJZhengsen Jia
Zhengsen Jia
QWQiang Wang
Qiang Wang
ZFZhanjun Fang
Zhanjun Fang
A local time scale can be generated by steering flywheel clocks with state-of-the-art optical lattice clocks. This paper presents our simulations about the influence of the optical lattice clock’s operational strategies and the flywheel clock’s noise characteristics on the performance of the generated time scale. By post-processing the measured frequency difference between the optical lattice clock Sr1 and the hydrogen maser HM50 at the National Institute of Metrology (NIM), during the modified Julian date (MJD) 59029–59059, a local time scale with 0.68 ns time variation referencing to the TT(BIPM20) is demonstrated.

28 January 2025 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
WSWei Song
Wei Song
DYDayu Yan
Dayu Yan
CSChuang Shi
Chuang Shi
Fu ZhengFu Zheng
Fu Zheng
CWCaicong Wu
Caicong Wu
Xiaolin MengXiaolin Meng
Xiaolin Meng
Time synchronization is a critical requirement in sixth-generation (6G) communication systems and Internet of Things (IoT) applications. However, the standard timing services provided by global navigation satellite systems (GNSS) are increasingly unable to meet the growing demands for precision and stability in modern networks. The proposed system leverages a single-difference time transfer (SDPT) method to achieve tens of picoseconds precision, enabling effective clock disciplining for oven-controlled crystal oscillators (OCXO). A clock disciplining within a phase-locked loop (PLL) structure further optimizes the output of time and frequency signals, enhancing OCXO stability. Additionally, a differential precise time synchronization system (DPTSS) by BeiDou navigation satellite system (BDS)/ global positioning system (GPS) is developed to deliver high-precision time reference signals for communication networks. Experimental results demonstrate that the real-time 1 pulse-per-second (1PPS) interval achieved by the BDS/GPS time link is better than 0.1 ns, with long-term frequency stability reaching the 10-16 level. Furthermore, the proposed system achieves a 1PPS signal synchronization precision of 0.73 ns in communication networks, significantly outperforming the other state-of-the-art methods.

16 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZJZhengsen Jia
Zhengsen Jia
YWYuzhuo Wang
Yuzhuo Wang
JDJie Ding
Jie Ding
QXQian Xu
Qian Xu
YZYadongyang Zhu
Yadongyang Zhu
This paper introduces an FPGA-based time-to-digital converter with an online dual-chain calibration method to address time resolution and linearity issues arising from the non-uniformity of FPGA internal delay elements. The aim is to enhance the stability and accuracy of time-to-digital converters under varying environmental conditions. We employ an external high-precision clock to generate start-stop calibration signals for real-time monitoring of signal propagation time changes within FPGA components. Two identical delay chains in the time-to-digital converter are managed by a Finite State Machine to switch their roles, ensuring continuous data acquisition and online calibration. Experimental results show that the proposed time-to-digital converter significantly outperforms traditional time interval counter in terms of time linearity, maximum integral nonlinearity, and differential nonlinearity. Within a temperature range of 20°C to 80°C, post-online temperature calibration maintains the root mean square of the TDC below 20 ps, substantially improving performance across different temperature conditions.

14 June 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
YWYuzhuo Wang
Yuzhuo Wang
AZAimin Zhang
Aimin Zhang
YGYuan Gao
Yuan Gao
QXQinghua Xu
Qinghua Xu
YLYige Lin
Yige Lin
A random pursuit strategy was further developed to minimize the uncertainty of atomic clock prediction errors by applying a new weighting method in its predictor ensemble. It was applied to experimental data from a hydrogen maser maintained at the timekeeping laboratory of the National Institute of Metrology in China. Compared to the method in our previous work, the new strategy moderately reduces the prediction uncertainty of the hydrogen maser. It could be a useful tool for some cases of clock prediction or other aspects.