Nora Abdullah

Nora Abdullah

Auto-generated profile, based on publicly available information

Nora Abdullah

Universitas Syiah Kuala

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
TSTaufiq Saidi
Taufiq Saidi
TATeuku Budi Aulia
Teuku Budi Aulia
BSBambang Setiawan
Bambang Setiawan
NANora Abdullah
Nora Abdullah
Muttaqin HasanMuttaqin Hasan
Muttaqin Hasan
Reliable spectral displacement (SD) in a wide range of response periods is crucial in seismic vulnerability assessment for Banda Aceh-Indonesia as the city is founded on a thick-soft soil. This SD is excellent for estimating building drift ratio from which the vulnerability of building is assessed. SD can be obtained from conversion of the acceleration spectra (converted SD) and site response analysis (analyzed SD). In this paper, both converted- and analysed-SDs are developed for Banda Aceh’s soft soil case using three historical seismic events of the 2012 Simeulue II, the 2013 Mane-Geumpang, and the 2013 Bener Meriah earthquakes and three soil models from which acceleration-displacement response spectrum (ADRS) of Banda Aceh’s soft soil is proposed. This proposed ADRS is compared to the generic response spectra of Centre of Research and Development of Housing and Settlement (PUSKIM) Indonesia. It can be concluded that the Proposed ADRSs can be used as another source in determining the performance of a building beside the PUSKIM ADRSs. Furthermore, the developed SDs were used to calculate the drift of 2-, 3-, and 4-storey typical shop-house buildings at Banda Aceh-Indonesia.

12 September 2018 in MATEC Web of Conferences
Verified
Journal Article
Open access
HYHalida Yunita
Halida Yunita
BSBambang Setiawan
Bambang Setiawan
TSTaufiq Saidi
Taufiq Saidi
NANora Abdullah
Nora Abdullah
The city of Banda Aceh is potentially exposed to a significant seismic hazard of seismic site amplification. Estimation of seismic site amplification of the city is urgently required for any mitigation efforts as the city is founded on a thick, soft layer. This study aims to estimate seismic site amplification of Banda Aceh's soil. Analytical models have demonstrated that they can simulate reasonably well the seismic ground motions amplification. The most widely used model is the equivalent linear approach. The approach computes the ground response of horizontally layered soil deposits subjected to transient and vertically propagating shear waves through a one-dimensional soil column. As aforementioned, this study focuses on Banda Aceh-Indonesia which is founded on thick alluvium. Three actual historical time histories and three developed sub-surface models were used to estimate the seismic site amplification of Banda Aceh's soft soil. The used time histories are of 2012 M8.1 Simeulue earthquake, 2013 M6.0 Mane-Geumpang earthquake and 2013 M6.2 Bener Meriah earthquake. Three sub-surface models of three separate sites across the city of Banda Aceh were developed. The site response analysis results reveal the ground motions amplification of Banda Aceh's soils of up to 4.3. Thus, applying the seismic site amplification for structural design at Banda Aceh can be further works.

29 November 2022 in Jurnal Teknik Sipil
Verified
Journal Article
Open access
PDF file
NANora Abdullah
Nora Abdullah
CRCut Ranian
Cut Ranian
IHIvan Hardi
Ivan Hardi
KKKurniawan Kurniawan
Kurniawan Kurniawan
MSMukhayar Syauki
Mukhayar Syauki
Due to the difference in concrete mix design method that applied in Standar Nasional Indonesia, SNI (Indonesian National Standard) in the last 25 years, which SNI 03-2834-2000 is adopted from DOE method and SNI 7656-2021 is adopted from ACI 211.1 methods, it is important to understand what is the relationship between concrete compressive strength with its tensile strength (splitting and flexural tensile strength) especially if there is an admixture applied in the concrete mixture. To study this relationship, specimens for each water cement ratio (0,35; 0,40; and 0,45) and super plasticizer dosage (0; 0,4 liter/100 kg PC; and 0,6 liter/100 kg PC) were prepared for compressive strength, splitting, and flexural tensile strength tests at 28 days. The main factor that affected concrete strength both for ACI 211.1 or DOE concrete mix design method is the aggregate composition. The results showed that the splitting tensile strength and the flexural tensile strength of concrete in this research is 4%-15% and 6%-21% of compressive strength, respectively. The decreasing trend of concrete compressive strength as the increasing of the water cement ration complied the general rule. While the increasing of super plasticizer dosage shows inclination trend of the compressive strength. However, the splitting and failure tensile strength shows different trend for interaction of concrete mixed design with super plasticizer dosage or with water cement ratio. In addition, the compressive strength to splitting tensile strength or flexural strength relationship in this research shows the similar trend with the ACI 318 and CEB-FIP codes but the compressive strength is less compare to both codes.

26 July 2024 in Journal of The Civil Engineering Student
Verified
Journal Article
Open access
PDF file
YMYudia Muctasya
Yudia Muctasya
YHYulia Hayati
Yulia Hayati
NANora Abdullah
Nora Abdullah
Perkembangan teknologi sekarang ini mengalami kemajuan pesat, salah satu contohnya pada konstruksi bangunan gedung. contoh kemajuan dari perkembangan teknologi di bidang konstruksi gedung adalah dengan hadirnya pelat Bondek. Pembangunan Gedung Kuliah Fakultas Ilmu Budaya ISBI Aceh merupakan salah satu konstruksi bangunan gedung yang menggunakan pelat Bondek dan tulangan wiremesh dalam perencanaannya. Penelitian ini bertujuan untuk mengetahui kapasitas lentur pelat Bondek dan perilaku struktur pelat Bondek tersebut yang berupa hubungan momen kurvatur dari pelat Bondek. Hasil analisis penelitian diperoleh Kapasitas momen lentur pada pelat Bondek aman digunakan, karena ØMn Mu. Di mana angka aman adalah 3,4084. Adapun perilaku struktur yang berupa momen dan kurvatur menghasilkan pada saat retak pertama kali pada beton diperoleh momen sebesar 11270452,56 Nmm dan kurvatur sebesar 2,8101 x 10-6 rad/mm, pada saat leleh pertama kali pada baja tulangan tarik diperoleh momen sebesar 28671938,61 Nmm dan kurvatur sebesar 4,598 x 10-5, dan pada kondisi ultimit diperoleh momen sebesar 32414717,08 Nmm dan kurvatur sebesar 7,7742 x 10-5 rad/mm.

11 February 2025
Verified
Book Chapter
Closed access
PDF file
NANora Abdullah
Nora Abdullah
SBSurya Bermansyah
Surya Bermansyah
MAMahlil
Mahlil
AUAdrian Ulza
Adrian Ulza
WMWilamaya Melati
Wilamaya Melati