1 June 2023 in Review of Scientific Instruments
Plasma Position Reflectometry (PPR) is planned to provide plasma position and shape information for plasma operation in future fusion reactors. Its primary function is to calibrate the drift of the magnetic signals due to the integral nature of magnetic measurement. Here, we attempt to measure plasma position using ordinary mode (O-mode) and extraordinary mode (X-mode) reflectometry systems on two tokamaks. A new physical model based on the phase shift is proposed to deduce the relative movement of the cut-off layer without density inversion. We demonstrate the plasma position measurements by absolute measurement from density profile inversion and relative measurement from phase shift. The combination of X-mode and O-mode reflectometers can minimize the limitations of single polarization reflectometry and further increase the accuracy of plasma position measurement. These results could provide an important technical basis for the further development of a real-time control system based on PPR.
1 January 2023 in Review of Scientific Instruments
To measure plasma density and magnetic fluctuations on the HL-2M tokamak simultaneously, a new diagnostic system combining Doppler backscattering (DBS) and cross-polarization scattering (CPS) is under development. It is essential to understand the propagation of injected and scattered rays to support the electronic/quasi-optical design and subsequent interpretation of the detected signals of the multi-channel DBS/CPS measurements. Thus, ray-tracing analysis with the axisymmetric ray-tracing code BORAY has been performed to estimate the scattering location and wavenumbers of the density and magnetic fluctuations. In addition, the influence of accordance between toroidal and poloidal launch angles is investigated. The received DBS/CPS signal quality can be improved by matching the parallel wavenumber in the direction of magnetic field lines.
1 December 2020 in Fusion Engineering and Design
1 September 2023 in Review of Scientific Instruments
A 105 GHz collective Thomson scattering (CTS) diagnostic has been successfully developed for fast-ion measurements on the HL-2A tokamak, and it has been deployed during an experimental campaign. Enhanced signals exhibiting synchronous modulation characteristics have been observed across all CTS channels upon the launch of a modulated probe wave. Results show that the intensity of the CTS signal increases with Neutral Beam Injection (NBI) power and is proportional to neutron count, indicating that the scattering signal contains a contribution from fast ions. Compared with the signal without NBI, the enhanced scattering spectrum due to NBI is slightly wider than the predicted fast ion range. Such broadening might be attributed to the heating effects of the gyrotron.
1 November 2024 in Review of Scientific Instruments
A new quasi-optical (QO) Electron Cyclotron Emission (ECE) transmission system has been established on the HL-3 tokamak, which includes a focusing QO mirror combination and a long-distance transmission line. This system was developed to meet the requirements for poloidal spatial resolution and the high signal-to-noise ratio needed for magnetohydrodynamic (MHD) instability studies using ECE on the HL-3. The QO mirror combination was installed inside the vacuum chamber for focusing. Laboratory test results, theoretical calculations, and synthetic ECE simulation results indicate that the Gaussian beam can meet the spatial resolution requirements for the accurate measurement of the MHD instability on the q = 1/2/3 surfaces, corresponding to the poloidal mode numbers m = 3/6/9. This includes good diagnostic poloidal spatial resolution for the important 2/1 and 3/2 modes. At the front end of the transmission line, a high-efficiency mode converter was designed to transition the TE10 mode to the HE11 mode for input into the transmission line, with an insertion loss of less than 1.5 dB. A 30 m long-distance corrugated oversized waveguide was constructed, with transmission losses ranging from 6 to 10 dB in the 60–120 GHz range. Polarization adjustment results show that the polarization offset and geometric spatial polarization angle change consistently, which can provide a reference for polarization adjustment in other complex structured transmission lines. The newly established ECE QO transmission system will provide strong support for future physics research involving ECE on the HL-3.