Timothy J. Held

Timothy J. Held

Auto-generated profile, based on publicly available information

Timothy J. Held

Echogen Power Systems , Akron, OH 44308

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in Combustion and Flame
Verified
Journal Article
Closed access
Chongwen ZhouChongwen Zhou
Chongwen Zhou
YLYang Li
Yang Li
EOEoin O'COnnor
Eoin O'COnnor
KSKieran P. Somers
Kieran P. Somers
STSébastien Thion
Sébastien Thion
HCHenry J. Curran
Henry J. Curran

21 March 2025 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
THTimothy J. Held
Timothy J. Held
JMJason Miller
Jason Miller
JMJason Mallinak
Jason Mallinak
LMLuke Magyar
Luke Magyar
Electrification of heat-generating processes is a key means to decarbonize industrial emissions, and heat pumps significantly improve the efficiency of electrified heat. Carbon dioxide is one of the oldest known heat pump working fluids, but its use is presently limited to low temperature (< 120 °C) applications and, when operating in a transcritical mode, for heating liquid water and similar single-phase materials. Conventional subcritical HFC or HFO refrigerants also have temperature limitations due to thermal degradation and are subject to eventual phase-out. Finally, most smaller heat pump systems use oil-lubricated positive displacement compressors, which also impose temperature limitations due to the thermal stability of the entrained oil in the refrigerant. By taking advantage of oil-free, turbomachinery-based equipment and using CO2 as the refrigerant, the temperature limitations of existing heat pump solutions can be eliminated. Novel cycle architectures, partially derived from sCO2 power cycle concepts, have been developed that significantly improve the performance of CO2 heat pumps relative to conventional vapor compression architectures, both for single-phase material heating and for medium pressure steam generation. Cycle simulations of these new heat pump cycles that cover a wide range of conditions and applications have been completed. Pilot-scale (< 50 kWth) demonstration systems have been built and tested, and their measured performance provides validating data for the simulated results.

29 January 2025 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
THTimothy J. Held
Timothy J. Held
JMJason Miller
Jason Miller
KSKyle Sedlacko
Kyle Sedlacko
JCJoshua D. Cameron
Joshua D. Cameron
SMScott C. Morris
Scott C. Morris
MTMark Turner
Mark Turner
Pumped thermal energy storage (PTES) offers a cost-effective means to store electrical energy for long duration by utilizing a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR). The heat pump compressor, which represents a significant driver to the cost, performance and operating characteristics of the PTES system. During charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. The conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. At steady state, full power operation, the isentropic efficiency and mechanical efficiency of the compressor have significant impact on the cycle design and round trip efficiency of the PTES system. The results of the conceptual design were used to refine the PTES cycle design and updated operating conditions provided for further aero design optimization. An important characteristic of the PTES system is its ability to charge at variable rate, which provides significant challenges on compressor operability, especially for a compressor that will be coupled to a fixed-speed synchronous motor. Cycle studies of variable charging rate processes have been conducted, and the impact of compressor operating map characteristics explored. Based on initial modeling studies, single compressor operation can be achieved down to at least 50% of rated power, with further reductions possible depending on the characteristics of the compressor map speedlines.

20 January 2025 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
JKJeongseek Kang
Jeongseek Kang
AVAlexander Vorobiev
Alexander Vorobiev
JCJoshua D. Cameron
Joshua D. Cameron
SMScott C. Morris
Scott C. Morris
MTMark Turner
Mark Turner
THTimothy J. Held
Timothy J. Held
The thermodynamic properties of CO2 do not obey the ideal gas law and the simplified equation of state. The enthalpy and sonic speed depend on both temperature and pressure whereas the enthalpy and the speed of sound of ideal gas, like atmospheric air, depend only on its temperature. These effects add additional complexity to the design and operation of CO2 compressors compared to compressors utilizing air as their working fluid. For example, if the compressor inlet pressure changes during operation, its flow Mach number changes due to the change of the sonic speed which is followed by the change of corrected speed and the performance. This paper focused on the experimental investigation of the performance parameters of a 1.5 stage axial compressor with CO2 gas. The design speed and the design pressure ratio of the compressor are 19,800 rpm and 1.41 respectively. The testing was completed using a 10MW closed CO2 compressor test loop at the University of Notre Dame Turbomachinery Laboratory. The compressor performance was measured at various compressor inlet conditions to demonstrate the effectiveness of the generalized corrected speed and the corrected flow coefficient in the CO2 compressor performance. Additionally, it is shown that the Reynolds number is connected to other performance parameters through the sonic speed and a set of experimental data is presented with an attempt to separate the effect of the Reynolds number and the effect of the corrected speed on the compressor performance.

8 December 2025 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Open access
JKJeongseek Kang
Jeongseek Kang
AVAlexander Vorobiev
Alexander Vorobiev
JSJames Sutton
James Sutton
WSWilliam Stewart
William Stewart
HMHarold Miller
Harold Miller
THTimothy J. Held
Timothy J. Held
Performance testing of a three-stage 9 MW axial CO2 compressor has been successfully completed at the closed-loop CO2 compressor test facility at the University of Notre Dame. The design speed, inlet pressure, inlet temperature, and mass flowrate of the compressor were 19,800 rpm, 2.77 MPa, 98 °C, and 125.9 kg/s, respectively. The compressor performance was evaluated from 60% to 100% of the design speed. Each speedline covered operating points from choke to near stall except for at 60% speed, where the compressor was throttled into rotating stall. Blade tip clearance and blade vibrations were measured during the compressor operation to ensure the safety of the compressor. Calibrated capacitance probes were used to establish average running tip clearances of 0.38 mm (1.2% of span), 0.5 mm (1.9% of span), and 0.5 mm (2.4% of span) for stage 1, stage 2, and stage 3, respectively. Blade vibrations were measured using tip timing probes. A six engine-order synchronous blade vibration of the first bending mode was observed at the first stage rotor around 73–82% speed. Stall testing at 60% speed revealed a single stall cell, which extends from the first stage rotor to the third stage rotor, and is rotating at 60.4% of the shaft speed. The compressor stall at 60% caused significant shaft vibration. Hence, the stall line at 70% and higher speeds was extrapolated from stall testing at 60% and lower speed to avoid potential damage of the test rig from stall or surge. The measured peak isentropic efficiency of the compressor was 91.5%, 91.1%, 90.6%, 90.0%, 85.3% at 60%, 70%, 83%, 90%, and 100% speeds, respectively. Considering increases in efficiency with decreases in mass flowrate and that the performance test above 70% was stopped with some safety distance away from the stall point to avoid damage, the peak isentropic efficiency is expected to be above or close to 90% at 100% speed as well. The measured performance successfully demonstrated the performance benefit and usefulness of the axial compressor for grid-scale energy systems such as pumped thermal energy storage (PTES).

30 August 2021
Verified
Report
Open access
PDF file
JMJason D Miller
Jason D Miller
JMJason Mallinak
Jason Mallinak
THTimothy J Held
Timothy J Held
The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO2) large-scale pilot. This transformational technology uses sCO2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO2 canmore » offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system. « less