13 June 2023 in IEEE Transactions on Power Electronics
The low-voltage ride-through (LVRT) capability of the doubly-fed induction generator (DFIG) based on the conventional excitation converter is insufficient under severe grid faults. The reason is that the dynamic rotor electromotive forces (EMF) will far exceed the dc-link voltage. To solve this issue, this letter proposes an enhanced excitation converter with parallel/series dc-link based on the triple active bridge (TAB) for DFIG. The dc-link of the enhanced excitation converter consists of the TAB and switching circuit, replacing the capacitive-type dc-link. Based on this topology, the dc-link voltage can increase instantaneously during severe grid faults to resist rotor EMF and improve the LVRT capability of DFIG. Compared with existing LVRT schemes, the enhanced excitation converter enables DFIG to achieve LVRT and inject the reactive current requirements of the grid code into the grid under severe grid faults. Finally, experiments verified the effectiveness of the proposed enhanced excitation converter and its control strategy.
26 March 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Dual active bridge (DAB) is commonly used as the dc–dc stage in solid state transformers (SSTs) due to its advantages of isolation, high-power density, and bidirectional power flow. As the core component of the DAB, the high-frequency transformer (HFT) directly affects the safe and stable operation of SSTs. With the continuous improvement in the voltage level and transmission power, the working environment of the HFT is becoming increasingly severe, and the risk of internal faults is also increasing. Therefore, it is significant to monitor the winding state of the HFT and to give early warning for the internal faults. Considering that the winding state can be reflected by short-circuit parameters, this article proposes an online identification method of HFT short-circuit parameters based on the instantaneous phasor method. In the proposed method, the fundamental components of the voltage and current signals in the primary and the secondary windings are first extracted by multiple second-order generalized integrators (MSOGIs) algorithm. And the online identification of HFT short-circuit parameters can thus be realized based on the extracted fundamental components. Finally, the effectiveness of the proposed method is experimentally verified on the DAB prototype.
4 July 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Cascaded H-bridge (CHB) topology receives wide attention in the battery energy storage systems (BESSs) due to its modular structure. When the finite-set model predictive control (FS-MPC) is applied to handle with the complex issues of the three-phase CHB-based BESSs, the problem of computation amount is emerging due to its traversal algorithm. In this paper, a successive searching algorithm for the FS-MPC is proposed to simplify the traversal subset. In the three-phase space-vector diagram, the proposed algorithm successively adjusts the searching direction to find the optimal voltage vector, according to the cost functions of the adjacent vector table. Moreover, the candidate vectors of the proposed algorithm are further modified by eliminating the repeated vectors and the unnecessary searching directions ultimately. The algorithm is readily applicable to the CHB-based BESSs and is also general to the other multilevel converters. Theoretical analysis and experimental comparison demonstrate the proposal.
24 October 2025 in IEEE Transactions on Industrial Electronics
Direct model predictive control (DMPC) effectively integrates multiobjective control and modulation processes into a single stage while handling constraints. However, the classical DMPC method faces computational challenges in cascaded H-bridge static var generator (CHB-SVG) due to the exponential growth of finite control sets. This work proposes an efficient DMPC method for CHB-SVG constructed by three stages: current tracking, phase voltage balancing, and module voltage balancing. The current tracking optimization stage is reformulated as Euclidean distance minimization and solved in a 120${}^{\circ}$ coordinate system. Analytical solution for optimal voltage levels is derived to ensure phase voltages equilibrium. Complementary switching states are introduced within the module voltage balancing stage, improving voltages balancing performance. This approach effectively reduces the complexity of the current and phase voltage balance control from untraceable polynomial time to a constant executable time. Both simulation and experimental results confirm the effectiveness of the proposed method.
19 January 2026 in IEEE Transactions on Industrial Electronics
During asymmetrical grid faults, the control of the doubly fed induction generator (DFIG) must simultaneously consider both grid code requirements and the system’s intrinsic constraints. This work proposes an asymmetrical grid fault ride-through control strategy for DFIG simultaneously considering dc-link voltage limitation, positive- and negative-sequence reactive current requirements, and electromagnetic torque oscillations. The method effectively mitigates RSC over-modulation imposed by the dc-link voltage limit and maintains control of the DFIG during asymmetrical grid faults while providing reactive current support. By fully utilizing the dc-link voltage, electromagnetic torque oscillations are minimized to the greatest extent possible. Meanwhile, the range of operating conditions within which the reactive current requirements can be satisfied is significantly expanded. The effectiveness of the proposed strategy is verified by both simulations and experimental data.
1 January 2026 in IEEE Transactions on Industrial Electronics