Fill dam structures are generally considered safe, but frequent heavy rainfall in recent years due to climate change has increased their risk of collapse. Technologies for the monitoring and safety management of these structures have attracted considerable attention, and methods to utilize technologies such as artificial intelligence (AI) and Internet of Things (IoT) for maintenance have been investigated. However, the measurement and communication processes of sensors used in the IoT technology are prone to measurement errors. Moreover, the communication environment and frequency range used by unlicensed operators vary within a country. Technologies for accurate interpretation of measurement results and optimal communication are required to address these issues. In this study, a technology for dam safety management and communication environment optimization was developed using AIoT (AI+IoT), and its field applicability was verified.
This paper presents the reliability-based resistance factor calibration of driven steel pipe piles and the implementation of Load and Resistance Factor Design (LRFD) on practical design cases. Resistance factors of driven steel pipe piles were calibrated in the framework based on reliability theory using static pile load test results. The results of fifty seven load tests conducted to failure were compiled and these 57 data were divided into three different groups based on their data quality. For the three groups, reliability analyses were performed for two static bearing capacity equations and for different target reliability indices (2.0 and 2.33 for group piles and 2.5 for single piles) following the First-Order Reliability Method (FORM) and using the Monte Carlo Simulation (MCS). It is noted that the resistance factors were highly dependent on the quality of load test data. To implement the calibrated resistance factors, a case study on an actual bridge foundation design was performed. The case study result showed that, for the given target reliability index, the developed LRFD method using the resistance factors calibrated in this study could contribute to cost savings when it is compared with Allowable Stress Design (ASD) case using a safety factor of 3.0.
Resistance factors for static bearing capacity of driven steel pipe piles were calibrated in the framework of reliability theory. In order for the verification of resistance factors and the implementation of the LRFD, a case study on an actual bridge foundation designs using both the ASD and the LRFD methods is comprehensively accomplished. Detailed analysis showed that both of the design concepts gave the design bearing capacities equal to or more than the design loads. The LRFD method, however, could provide the quantitative provability of failure of the pile foundation, whereas the ASD method showed nominal level of safety.
15 December 2022 in Georisk: Assessment and Management of Risk for Engineered Systems and Geohazards
Ground conditions comprised of slightly or completely weathered rock are frequently encountered in design of bridge foundations in Korea. It is rather challenging to assess the accuracy of the common design methodologies for shallow foundations in these ground conditions as the foundation bearing capacity depends on the degree of weathering. This paper presents reliability-based derivation of resistance factors for the bearing capacity of shallow foundations on slightly and completely weathered rock using field plate load test data. More than 140 plate load tests were performed at 52 sites, 33 of which were considered to be of high quality and reliable. These high-quality tests were used to evaluate the uncertainties associated with the bearing capacity equations, and the resistance factors corresponding to current prescribed load factors. A reliability-based approach, with target annual failure probabilities of 1.0 × 10−3, 2.0 × 10−4, 1.0 × 10−4, was adopted to estimate the required resistance factors for different design equations. A Bayesian approach was adopted to facilitate quantification and propagation of statistical parameter uncertainty due to limited available data. The best estimates of the calibrated resistance factors range from 0.40 to about 0.47 for the considered target reliability levels, which is in good agreement with currently used values in Korea.
Resistance bias factors for the two static bearing capacity analysis methods of driven steel pipe piles adopted in the Korean Design Standards for Structure Foundations were evaluated as part of study to develop LRFD codes for foundation structures in South Korea. Of the 2,227 static load test data on driven steel pipe piles collected from all around the country, only 43 were found to be useful for this study. These load test piles were sorted into two cases: pile tip in soil case and pile tip in rock case. Pile bearing capacities were measured from the load-displacement curves by six different failure criteria, and Davisson's criterion was found to be most reliable. Statistical analysis of the resistance bias factors was performed, and the results show a significantly high degree of variation in the resistance bias factors.