29 November 2023 in IEEE Transactions on Industrial Informatics
Electricity theft users with zero electricity usage (UZEU) should be specifically concerned in electricity theft detection (ETD) research. The challenges are: they provide no effective information on electricity usage behaviors, and they are easily confused with vacant house users. This has caused the majority of the existing detection methods relying on single electricity usage to fail to identify UZEU accurately. Hence, this article first analyzes the underlying correlation between water and electricity (W&E) usage collected by the smart meter. This analysis then lends the theoretical basis to propose a new ETD method by comprehensively using the multisource information. More precisely, the proposed method utilizes the mutual information coefficient (MIC) to construct a correlation model between W&E usage and in turn the wavelet clustering algorithm to cluster the MIC of the power distribution users. Thereafter, the resulting weak correlations indicate the suspected users as the electricity theft UZEU in case of zero electricity usage. Finally, the proposed method is validated by numerical experiments in the real world and illustrated to be more accurate than existing methods in detecting UZEU.
6 January 2025 in IEEE Access
The construction of smart cities contributes to promoting residents’ life convenience and sustainable energy development. Despite these advancements, the challenge of fully analyzing and understanding residents’ energy usage behaviors leads to inefficient energy use and potential economic losses. Current resident anomaly detection technologies rely on single-source energy data, lacking detailed behavior pattern analysis. Hence, this paper proposes a method to detect abnormal residential water and electricity usage by incorporating multi-source information. Specifically, the correlation between water and electricity usage of residential customers is analyzed based on real metering data and the use of the Copula distribution function, followed by the integration of two innovative data mining techniques to form an anomaly detection framework. The distance correlation coefficient algorithm is used to measure the relevance of users’ water and electricity usage data. Then, the Density-Based Spatial Clustering of Applications with Noise (DBSCAN) algorithm is utilized to cluster the distance correlation coefficient for users and detect abnormal users whose distance correlation coefficient curves deviate from the normal user clusters. This multi-source approach avoids single-source bias by improving the data accuracy over one-dimensional methods. Experiments are implemented in a real low-voltage transformer area to prove the validity of the proposed method.