Neal Kumar Bhatia

Neal Kumar Bhatia

Auto-generated profile, based on publicly available information

Neal Kumar Bhatia

Emory University, Atlanta, Georgia, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Heart Rhythm
Verified
Journal Article
Closed access
MAMounir Al-Gibbawi
Mounir Al-Gibbawi
HAHakeem O. Ayinde
Hakeem O. Ayinde
NBNeal K. Bhatia
Neal K. Bhatia
MEMikhael F El-Chami
Mikhael F El-Chami
SWStacy B. Westerman
Stacy B. Westerman
SKSoroosh Kiani
Soroosh Kiani

1 June 2020 in EP Europace
Verified
Journal Article
Open access
PDF file
NBNeal K Bhatia
Neal K Bhatia
ARAlbert J Rogers
Albert J Rogers
DKDavid E Krummen
David E Krummen
SHSamir Hossainy
Samir Hossainy
WSWilliam Sauer
William Sauer
SNSanjiv M. Narayan
Sanjiv M. Narayan
Persistent atrial fibrillation (AF) has been explained by multiple mechanisms which, while they conflict, all agree that more disorganized AF is more difficult to treat than organized AF. We hypothesized that persistent AF consists of interacting organized areas which may enlarge, shrink or coalesce, and that patients whose AF areas enlarge by ablation are more likely to respond to therapy. We mapped vectorial propagation in persistent AF using wavefront fields (WFF), constructed from raw unipolar electrograms at 64-pole basket catheters, during ablation until termination (Group 1, N = 20 patients) or cardioversion (Group 2, N = 20 patients). Wavefront field mapping of patients (age 61.1 ± 13.2 years, left atrium 47.1 ± 6.9 mm) at baseline showed 4.6 ± 1.0 organized areas, each separated by disorganization. Ablation of sites that led to termination controlled larger organized area than competing sites (44.1 ± 11.1% vs. 22.4 ± 7.0%, P < 0.001). In Group 1, ablation progressively enlarged unablated areas (rising from 32.2 ± 15.7% to 44.1 ± 11.1% of mapped atrium, P < 0.0001). In Group 2, organized areas did not enlarge but contracted during ablation (23.6 ± 6.3% to 15.2 ± 5.6%, P < 0.0001). Mapping wavefront vectors in persistent AF revealed competing organized areas. Ablation that progressively enlarged remaining areas was acutely successful, and sites where ablation terminated AF were surrounded by large organized areas. Patients in whom large organized areas did not emerge during ablation did not exhibit AF termination. Further studies should define how fibrillatory activity is organized within such areas and whether this approach can guide ablation.

1 June 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
NBNeal K. Bhatia
Neal K. Bhatia
RSRajan L. Shah
Rajan L. Shah
BDBrototo Deb
Brototo Deb
TPTerrence Pong
Terrence Pong
RKRidhima Kapoor
Ridhima Kapoor
ALAnson M. Lee
Anson M. Lee
BACKGROUND: Surgical ablation for atrial fibrillation (AF) can be effective, yet has mixed results. It is important to improve the success of AF surgery, yet unclear which endocardial lesions will best augment surgical lesion sets in individual patients. We addressed this question by systematically mapping AF endocardially after surgical ablation and relating findings to early recurrence. METHODS: We studied 81 consecutive patients undergoing epicardial surgical ablation (stage 1 hybrid), of whom 64 proceeded to endocardial catheter mapping and ablation (stage 2). Stage 2 comprised high-density mapping of pulmonary vein (PV) or posterior wall (PW) reconnections, low-voltage zones (LVZs), and potential localized AF drivers. We related findings to postsurgical recurrence of AF. RESULTS: Mapping at stage 2 revealed PW isolation reconnection in 59.4%, PV isolation reconnection in 28.1%, and LVZ in 42.2% of patients. Postsurgical recurrence of AF occurred in 36 patients (56.3%), particularly those with long-standing persistent AF (P=0.017), but had no relationship to reconnection of PVs (P=0.53) or PW isolation (P=0.75) when compared with those without postsurgical recurrence of AF. LVZs were more common in patients with postsurgical recurrence of AF (P=0.002), long-standing persistent AF (P=0.002), advanced age (P=0.03), and elevated CHA2DS2-VASc (P=0.046). AF mapping revealed 4.4±2.7 localized focal/rotational sites near and also remote from PV or PW reconnection. After ablation at patient-specific targets, arrhythmia freedom at 1 year was 81.0% including and 73.0% excluding previously ineffective antiarrhythmic medications. CONCLUSIONS: After surgical ablation, AF may recur by several modes including recovery of PW or PV isolation, mechanisms related to localized LVZ, or other sustaining mechanisms. LVZs are more common in patients at high clinical risk for recurrence. Patient-specific targeting of these mechanisms yields excellent long-term outcomes from hybrid ablation. Download figure Download PowerPoint

25 November 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
SIShahriar Iravanian
Shahriar Iravanian
IUIlija Uzelac
Ilija Uzelac
ASAnand D Shah
Anand D Shah
MTMikael J Toye
Mikael J Toye
MLMichael S Lloyd
Michael S Lloyd
FFFlavio H Fenton
Flavio H Fenton
The mechanisms of transition from regular rhythms to ventricular fibrillation (VF) are poorly understood. The concordant to discordant repolarization alternans pathway is extensively studied; however, despite its theoretical centrality, cannot guide ablation. We hypothesize that complex repolarization dynamics, i.e. oscillations in the repolarization phase of action potentials with periods over two of classic alternans, is a marker of electrically unstable substrate, and ablation of these areas has a stabilizing effect and may reduce the risk of VF. To prove the existence of higher-order periodicities in human hearts. We performed optical mapping of explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Signals recorded from the right ventricle endocardial surface were processed to detect global and local repolarization dynamics during rapid pacing. A statistically significant global 1:4 peak was seen in three of six hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of Periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. We present evidence of complex higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex vivo human hearts. We infer that the oscillation of the calcium cycling machinery is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability and may provide targets for substrate-based ablation of VF.

24 November 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
RIRand Ibrahim
Rand Ibrahim
MAMounir Al-Gibbawi
Mounir Al-Gibbawi
WMWissam Mekary
Wissam Mekary
NBNeal Kumar Bhatia
Neal Kumar Bhatia
SKSoroosh Kiani
Soroosh Kiani
MEMikhael F El-Chami
Mikhael F El-Chami
Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.

1 November 2021 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Open access
PDF file
DQDavid Qian
David Qian
ESE. Schreibmann
E. Schreibmann
NBN.K. Bhatia
N.K. Bhatia
SKS. Kiani
S. Kiani
MLM.S. Lloyd
M.S. Lloyd
KHK.A. Higgins
K.A. Higgins
Purpose/Objective(s) Nearly half of all patients with ventricular tachycardia (VT) become refractory to standard-of-care anti-arrhythmic medications and catheter ablation. Stereotactic body radiotherapy (SBRT) has emerged as a well-tolerated and effective new treatment for VT. Since arrhythmogenic lesions are undetectable on CT scans, the practice of SBRT target volume delineation is not yet formalized. Many single-institution protocols involve only verbal discussion between electrophysiologists and radiation oncologists or manual re-orientation of surface renderings from electrophysiologic (EP) studies to correlate with the planes on CT scan. We present a novel software, "Rhythm-RT", that synthesizes data from EP studies and heart contours from radiation planning to automatically generate a preliminary target volume. Materials/Methods Along with DICOM files containing contours, Rhythm-RT can process electroanatomic mapping (EAM) data from CARTO (Biosense Webster, Irvine, CA) and EnSite Precision (Abbott, St. Paul, MN) as well as ablation navigation data from EnSite Precision. All input data are plotted in the reference coordinate system of the CT simulation scan. The user is able to translate and rotate imported EP spatial information for co-registration with contoured cardiac substructures. Rhythm-RT then identifies the cardiac substructure closest to the sites of low voltage from EAM or inadequate previous ablation on which to generate an SBRT gross target volume (GTV), adapted to the myocardial shape and transmural thickness of the cardiac substructure. The GTV is exported as a DICOM file which can be integrated with other contoured structures in the original radiation planning system. Results From October 2019 to February 2021, 7 males and 1 female with VT (53–84 years of age, ejection fraction 10–65%, and 0–7 previous catheter ablations) were treated using Rhythm-RT to guide cardiac SBRT planning. Compared to existing methods of delineating GTV crudely by free-hand, Rhythm-RT visualizes EP spatial information superimposed on heart contours. The area of myocardium selected as GTV, based on proximity to relevant EP signals, is computationally derived rather than inferred and liable to human error. Final GTV modification with the help of an experienced electrophysiologist is still recommended. When structural heart disease is multifocal, he/she may provide insight on which areas are more likely to cause arrhythmia. Adjustment of the GTV boundary may also be informed by direct observations during EP procedures that are not reflected in procedure equipment logs. Conclusion Rhythm-RT is a software that improves the accuracy and efficiency of target volume delineation in cardiac SBRT. Additional patient enrollment on our institutional protocol utilizing this technology is ongoing, along with outcomes analysis and expansion of input data versatility to include all EP and radiation planning systems.