Charlton van der Horst

Charlton van der Horst

Auto-generated profile, based on publicly available information

Charlton van der Horst

SensorLab, Department of Chemistry, University of the Western Cape, Bellville 7535, South Africa

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2014 in Analytical Letters
Verified
Journal Article
Closed access
CHC. Van der Horst
C. Van der Horst
BSB. Silwana
B. Silwana
EIEmmanuel Iwuoha
Emmanuel Iwuoha
VSVernon Somerset
Vernon Somerset
Silver, bismuth, and bismuth-silver nanoparticles were synthesized and characterized by cyclic voltammetry, electrochemical impedance spectroscopy, ultraviolet-visible spectroscopy, infrared spectroscopy, Raman spectroscopy, and transmission electron microscopy to determine the electrochemical, optical, structural, and morphological properties of the nanomaterials. The silver, bismuth, and bismuth-silver nanoparticles were shown to have an average particle size of 10–30 nanometers by microscopy. The electrochemical results showed that the bismuth-silver nanoparticles exhibited good electrocatalytic activity that can be harnessed for sensor construction and related applications. The ultraviolet-visible, infrared, and Raman spectroscopy results confirmed the structural properties of the bismuth-silver nanoparticles. In addition, the microscopy and electron diffraction morphological characterization confirmed the nature of the bismuth-silver nanoparticles.

19 August 2014 in Journal of Environmental Science and Health, Part A
Verified
Journal Article
Closed access
BSBongiwe Silwana
Bongiwe Silwana
CHCharlton Van Der Horst
Charlton Van Der Horst
EIEmmanuel Iwuoha
Emmanuel Iwuoha
VSVernon Somerset
Vernon Somerset
This work was undertaken to develop a novel Pt/PANI-co-PDTDA/HRP biosensor system for environmental applications to investigate the inhibition studies by specific heavy metals, to provide data suitable for kinetic studies and further application of the biosensor to environmental samples. The newly constructed biosensor was compared to the data of the well-researched Pt/PANI/HRP biosensor. Optimised experimental conditions, such as the working pH for the biosensor was evaluated. The functionality of the amperometric enzyme sensor system was demonstrated by measuring the oxidation current of hydrogen peroxide followed by the development of an assay for determination of metal concentration in the presence of selected metal ions of Cd(2+), Pb(2+) and Hg(2+). The detection limits were found to be 8 × 10(-4) μg L(-1) for cadmium, 9.38 × 10(-4) μg L(-1) for lead and 7.89 × 10(-4) μg L(-1) for mercury. The World Health Organisation recommended that the maximum safety level of these metals should not exceed 0.005 mg L(-1) of Cd(2+), 0.01 mg L(-1) of Pb(2+) and 0.001 mg L(-1) of Hg(2+.), respectively. The analytical and detection data for the metals investigated were observed to be lower than concentrations recommended by several bodies including World Health Organisation and Environmental Protection Agencies. Therefore the biosensors developed in this study can be used to screen the presence of these metals in water samples because of its low detection limit. The modes of inhibition of horseradish peroxidase by Pb(2+), Cd(2+) and Hg(2+) as analysed using the double reciprocal plots of the Michaelis-Menten equation was found to be reversible and uncompetitive inhibition. Based on the Km(app) and Imax values for both biosensors the results have shown smaller values. These results also proved that the enzyme modified electrode is valuable and can be deployed for the determination or screening of heavy metals.

7 August 2012 in Journal of Environmental Science and Health, Part A
Verified
Journal Article
Closed access
CHC. van der Horst
C. van der Horst
BSB. Silwana
B. Silwana
EIEmmanuel Iwuoha
Emmanuel Iwuoha
VSVernon Somerset
Vernon Somerset
Stripping voltammetry as technique has proved to be very useful in the analysis of heavy and other metal ions due to its excellent detection limits and its sensitivity in the presence of different metal species or interfering ions. Recent assessments of aquatic samples have shown increased levels of platinum group metals (PGMs) in aquatic ecosystems, caused by automobile exhaust emissions and mining activities. The development of an analytical sensor for the detection and characterisation of PGMs were investigated, since there is an ongoing need to find new sensing materials with suitable recognition elements that can respond selectively and reversibly to specific metal ions in environmental samples. The work reported shows the successful application of another mercury-free sensor electrode for the determination of platinum group metals in environmental samples. The work reported in this study entails the use of a glassy carbon electrode modified with a bismuth film for the determination of platinum (Pt2+), palladium (Pd2+) or rhodium (Rh2+) by means of adsorptive cathodic stripping voltammetry. Optimised experimental conditions included composition of the supporting electrolyte, complexing agent concentration, deposition potential, deposition time and instrumental voltammetry parameters for Pt2+, Pd2+ and Rh2+ determination. Adsorptive differential pulse stripping voltammetric measurements for PGMs were performed in the presence of dimethylglyoxime (DMG) as complexing agent. The glassy carbon bismuth film electrode (GC/BiFE) employed in this study exhibit good and reproducible sensor characteristics. Application of GC/BiFE sensor exhibited well-defined peaks and highly linear behaviour for the stripping analysis of the PGMs in the concentration range between 0 and 3.5 μg/L. The detection limit of Pd, Pt and Rh was found to be 0.12 μg/L, 0.04 μg/L and 0.23 μg/L, respectively for the deposition times of 90 s (Pd) and 150 s (for both Pt and Rh). Good reproducibility was also observed and the practical applicability of the sensor was demonstrated with the analysis of environmental water and sediment samples.

1 September 2015 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
CHCharlton van der Horst
Charlton van der Horst
BSBongiwe Silwana
Bongiwe Silwana
EIEmmanuel Iwuoha
Emmanuel Iwuoha
VSVernon Somerset
Vernon Somerset

1 May 2014 in Electrochimica Acta
Verified
Journal Article
Closed access
BSBongiwe Silwana
Bongiwe Silwana
CHCharlton van der Horst
Charlton van der Horst
EIEmmanuel Iwuoha
Emmanuel Iwuoha
VSVernon Somerset
Vernon Somerset

1 October 2015 in Thin Solid Films
Verified
Journal Article
Closed access
BSBongiwe Silwana
Bongiwe Silwana
CHCharlton van der Horst
Charlton van der Horst
EIEmmanuel Iwuoha
Emmanuel Iwuoha
VSVernon Somerset
Vernon Somerset