Sandra K. Montgomery

Sandra K. Montgomery

Auto-generated profile, based on publicly available information

Sandra K. Montgomery

Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Dr, St. Louis, MO, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2023 in Journal of Materials Chemistry B
Verified
Journal Article
Open access
PDF file
AGAnna P. Goestenkors
Anna P. Goestenkors
TLTianran Liu
Tianran Liu
SOSomtochukwu S. Okafor
Somtochukwu S. Okafor
BSBarbara A. Semar
Barbara A. Semar
RARiley M. Alvarez
Riley M. Alvarez
ARAlexandra L. Rutz
Alexandra L. Rutz
The effect of gelling agent concentration (ionic liquid) on PEDOT:PSS hydrogel fabrication and properties was investigated. Gelation kinetics, stability, swelling, stiffness, conductivity, and support of seeded cells were characterized.

4 February 2025 in Advanced Materials Technologies
Verified
Journal Article
Closed access
SOSomtochukwu S. Okafor
Somtochukwu S. Okafor
JPJae Park
Jae Park
TLTianran Liu
Tianran Liu
AGAnna P. Goestenkors
Anna P. Goestenkors
RARiley M. Alvarez
Riley M. Alvarez
ARAlexandra L. Rutz
Alexandra L. Rutz

1 June 2026 in Advanced Functional Materials
Verified
Journal Article
Open access
PDF file
JPJae Park
Jae Park
TLTianran Liu
Tianran Liu
SOSomtochukwu S. Okafor
Somtochukwu S. Okafor
AGAnna P. Goestenkors
Anna P. Goestenkors
BSBarbara A. Semar
Barbara A. Semar
ARAlexandra L. Rutz
Alexandra L. Rutz
Active stiffness, the changing of material stiffness in response to an external stimulus, can be harnessed for mechanically adaptive implantable devices and dynamic cell culture substrates for mechanobiology investigations. Conducting polymer (CP)‐based materials are capable of changing stiffness in response to an applied electrical potential: redox‐driven changes in charge state lead to ion transport and subsequent swelling. This phenomenon has been investigated for polymeric actuators but rarely for active stiffness. In this study, the stiffness of poly(3,4‐ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT: PSS) films as a function of applied potential is characterized. Electrochemical preconditioning is first defined, and the proportionality of ion transport to voltage is identified. The maximum stiffness change observed over the potential range was found to be ∼32.5%, and changes of ∼6.7%–10.4% were found with 0.2 V increments. PEDOT: PSS films deviate in both their charge state and stiffness over a period of many hours after unbiasing. After unbiasing, PEDOT: PSS loses the transported charge over time and the stiffness changes by ∼2.6%–15.2% over 24 h. Finally, as a first step to evaluate the feasibility for biomedical applications, the active stiffness modulation process is determined to be cytocompatible. These characterizations highlight both the potential of CPs for active stiffness and identify areas for future optimization.

12 May 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
TLTianran Liu
Tianran Liu
JPJae Park
Jae Park
SOSomtochukwu S. Okafor
Somtochukwu S. Okafor
SMSandra K. Montgomery
Sandra K. Montgomery
AGAnna P. Goestenkors
Anna P. Goestenkors
ARAlexandra L. Rutz
Alexandra L. Rutz
Traditional bioelectronic devices are limited by poor biointerfacing due to their substantial mismatch in mechanical and biochemical properties. In tissue engineering, soft and bioactive materials support biointegration by harnessing or mimicking the natural extracellular matrix (ECM). Building bioelectronic devices from ECM should improve their biointegration, yet there are limited methods to fabricate them due to current manufacturing approaches. An additive manufacturing strategy is presented here for collagen-based bioelectronic interfaces that integrates conducting polymer electrodes with ECM-based substrates or encapsulation layers. Addition of poly(ethylene glycol) diglycidyl ether (PEGDE) to poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) colloidal dispersions enables direct extrusion-based patterning under mild conditions compatible with collagen substrates, and forms aqueous stable and highly conducting printed patterns (2788 S m⁻¹). The resulting interfaces maintain stable electrochemical performance over 7 days in physiological environments, and support primary human cell adhesion, viability, and proliferation across both material regions. A sacrificial patterning strategy using 3D printed cacao butter further enables spatial control of collagen encapsulation. This approach establishes a framework for fabricating functional bioelectronic devices based on ECM to further enhance device biointerfaces for tissue models and implantable systems.

12 May 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
SOSomtochukwu S. Okafor
Somtochukwu S. Okafor
SMSandra K. Montgomery
Sandra K. Montgomery
JPJae Park
Jae Park
TLTianran Liu
Tianran Liu
MSMbama Safrega
Mbama Safrega
ARAlexandra L. Rutz
Alexandra L. Rutz
Cancer is a significant contributor to global mortality and places a substantial burden on healthcare systems, underscoring the need for improved strategies for developing and evaluating new therapies. Electrochemical impedance monitoring of in vitro cancer models is a promising technique for evaluating treatment effectiveness, particularly for evaluating how well a drug may kill cancer cells. This approach is advantageous over conventional end-point assays because it is non-destructive, label-free, and can provide temporal information on cell behavior and drug kinetics. However, traditional impedance devices are limited in that they do not support three-dimensional cell culture that has become standard in cancer studies. Typical devices are planar substrates that support monolayer culture, which has been shown to overestimate drug effectiveness. In this work, we propose 3D printed bioelectronic scaffold devices that provide 3D cancer cell culture while functioning as an on-chip readout for monitoring changes in cell characteristics via impedance. We describe device development and demonstrate reproducible fabrication, stable electrochemical properties, cell detection by impedance, and proof-of-concept monitoring of cytotoxicity in response to a chemotherapeutic drug. Overall, this technology offers a promising platform that could be further developed for compound screening as part of drug development or precision medicine.

23 July 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
SOSomtochukwu S. Okafor
Somtochukwu S. Okafor
JPJae Park
Jae Park
TLTianran Liu
Tianran Liu
AGAnna P. Goestenkors
Anna P. Goestenkors
RARiley M. Alvarez
Riley M. Alvarez
ARAlexandra L. Rutz
Alexandra L. Rutz
3D printing is a leading technique for fabricating tissue engineering scaffolds that facilitate native cellular behavior. Engineering scaffolds to possess functional properties like electronic conductivity is the first step towards integrating new technological capabilities like stimulating or monitoring cellular activity beyond the traditionally presented biophysical and biochemical cues. However, these bioelectronic scaffolds have been largely underdeveloped since the majority of electrically conducting materials possess high stiffness values outside the physiological range and that may negatively impact desired cell behavior. Here, we present methods of 3D printing poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) hydrogel scaffolds and provide techniques to achieve stiffness relevant to many soft tissues (<100 kPa). Structures were confirmed as ideal tissue scaffolds by maintaining biostability and promoting high cell viability, appropriate cell morphology, and proliferation. With these findings, we contribute a customizable 3D platform that provides favorable soft cellular microenvironments and envision it to be adaptable to several bioelectronic applications.