1 January 2013 in Procedia Technology
Contact angle measurement has wide application in studying the wettability of a surface. This paper presents a contact angle measurement system developed using simple apparatus. The system consists of a bespoke measurement software, USB microscope, motorized linear position slider and a sample holder with back lighting system. The advantages of this system include user friendly, compact size, allow manual and automatic measurements and cost effective. This system is established with the contact angle and surface tension measurement experiment which is based on Fox-Zisman theory. Different probe liquids were suggested and the critical surface tension of polydimethylsiloxane (PDMS) and polyimide were determined using both the software and the hardware system developed
14 August 2017 in IOP Conference Series: Materials Science and Engineering
MSMuhammad Sharil Saripan
With the advancement in microfluidic technology, fluid flow control for syringe pump is always essential. In this paper, a mechatronic syringe pump will be developed and customized to control the fluid flow in a poly-dimethylsiloxane (PDMS) microfluidic device based on a polyimide laminating film. The syringe pump is designed to drive fluid with flow rates of 100 and 1000 μl/min which intended to drive continuous fluid in a polyimide based microfluidic device. The electronic system consists of an Arduino microcontroller board and a uni-polar stepper motor. In the system, the uni-polar stepper motor was coupled to a linear slider attached to the plunger of a syringe pump. As the motor rotates, the plunger pumps the liquid out of the syringe. The accuracy of the fluid flow rate was determined by adjusting the number of micro-step/revolution to drive the stepper motor to infuse fluid into the microfluidic device. With the precise control of the electronic system, the syringe pump could accurately inject fluid volume at 100 and 1000 μl/min into a microfluidic device.
1 June 2020 in Indonesian Journal of Electrical Engineering and Computer Science
SKSafinaz Binti Mohd Khialdin
Safinaz Binti Mohd Khialdin
JPJaysuman Bin Pusppanathan
Jaysuman Bin Pusppanathan
+1
The posture monitoring system monitors the posture changes of the upper body and the spinal cord applying to ophthalmologists while operating the slit lamp. The motivation to the pursuit of this system is to relate posture changes while in a static sitting posture to the spinal deviation from the g-line. Often times, the spinal deviation from the g-line is classified as bad posture because of the shift in weight distribution on the spine causing pain and discomfort in certain areas of the spine. This paper presents the design concept, the development process and the working principle of the posture monitoring system using Inertial Measurement Unit (IMU) sensor. The raw measurement data obtained from human trials is tabulated and converted into a graphical representation in which all postures can be identified and distinguished by referring the relative wave pattern. The procedure is important in the improvement on the posture monitoring system for the human trials on the ophthalmologist in future.
30 November 2024 in Journal of Advanced Research in Applied Mechanics
The number of elderlies increases over the years and has triggered concerns on healthcare system, the community and the family. Elderly could experience knee buckle and fall due knee osteoarthritis (OA), a common syndrome of weakness due to aging degeneration. It may cause pain and injuries and hence fears to stay mobile. As a result, this would give a negative effect to mental and physical health. It is common that elderlies attempt to wear an assistive knee device in hope of providing security in walking. The aim of this project is to survey the faith of elderlies in knee braces, to investigate the stiffness of sampled market knee braces/orthoses again sudden knee buckling and to propose a novelty design of a mechatronic knee orthosis. From the survey, the elderlies are general having faith in wearing a knee brace / orthosis to provide walking security. Secondly, from the experimental load test, the findings revealed that these sampled knee brace or orthoses do not feature on delayed bending when knee buckling occurred. Finally, the proposed design has revealed improved knee stiffness and prolong delayed knee bending.