Viruses, Giardia cysts, and Cryptosporidium parvum oocysts are all major causes of waterborne diseases that can be uniquely challenging in terms of inactivation/removal during water and wastewater treatment and water reuse. Ozone is a strong disinfectant that has been both studied and utilized in water treatment for more than a century. Despite the wealth of data examining ozone disinfection, direct comparison of results from different studies is challenging due to the complexity of aqueous ozone chemistry and the variety of the applied approaches. In this systematic review, an analysis of the available ozone disinfection data for viruses, Giardia cysts, and C. parvum oocysts, along with their corresponding surrogates, was performed. It was based on studies implementing procedures which produce reliable and comparable datasets. Datasets were compiled and compared with the current USEPA Ct models for ozone. Additionally, the use of non-pathogenic surrogate organisms for prediction of pathogen inactivation during ozone disinfection was evaluated. Based on second-order inactivation rate constants, it was determined that the inactivation efficiency of ozone decreases in the following order: Viruses >> Giardia cysts > C. parvum oocysts. The USEPA Ct models were found to be accurate to conservative in predicting inactivation of C. parvum oocysts and viruses, respectively, however they overestimate inactivation of Giardia cysts at ozone Ct values greater than ∼1 mg min L-1. Common surrogates of these pathogens, such as MS2 bacteriophage and Bacillus subtilis spores, were found to exhibit different inactivation kinetics to mammalian viruses and C. parvum oocysts, respectively. The compilation of data highlights the need for further studies on disinfection kinetics and inactivation mechanisms by ozone to better fit inactivation models as well as for proper selection of surrogate organisms.
Bromate, a regulated disinfection byproduct, forms during the ozonation of bromide through reactions with both ozone and hydroxyl radical. In this study, preformed monochloramine was evaluated for use as a bromate suppression method in pilot testing of wastewater reuse with an average bromide concentration of 422±20 µg/L. A dose of 3 mg/L NH2Cl-Cl2 decreased bromate formation by an average of 82% and was sufficient to keep bromate below the MCL at ozone doses up to 8.6 mg/L (1.2 O3:TOC). Removal of 1,4-dioxane through ozonation decreased with increasing NH2Cl dose, confirming that monochloramine suppresses bromate formation, at least in part, by acting as a hydroxyl radical scavenger. This may negatively impact oxidation objectives of ozonation in reuse applications. Increasing monochloramine contact time did not improve bromate suppression, indicating that monochloramine probably did not mask bromide as NHBrCl or other haloamines prior to ozonation. However, NHBrCl and NH2Br may be formed from reactions between HOBr and NH2Cl and excess free ammonia during ozonation. NDMA was formed by ozonation at concentrations up to 79 ng/L and was not enhanced by NH2Cl addition.
In drinking water applications, an ozone exposure (Ct) based framework has been historically used to validate ozone disinfection. However, significant viral inactivation can be achieved with little to no measurable ozone exposure. Additionally, ozone exposure depends on multiple water quality variables as well as the calculation/ozone measurement method used. In this study, we evaluated alternative ozone monitoring frameworks as well as the impact of water quality variables on ozone decay kinetics and virus/coliform inactivation. Here we show that both change in UV254 absorbance and applied O3:TOC were well correlated with viral inactivation and these frameworks were resilient to changes in water quality. Both increasing temperature (12-30 ⁰C) and pH (5.5-8.4) was shown to significantly increase the ozone decay rate and decreased the resulting ozone exposure by as much as ∼90% in the case of pH. However, due to the increased reaction rate of ozone with viruses at elevated temperature and pH, there was only a minor impact (∼20% in the case of pH) in overall disinfection performance for a given O3:TOC. These frameworks were also considered for variable source water with TOC (5-11 mg/L) and TSS (1.2-5.8 mg/L). Change in UV254 absorbance or applied ozone dose (mg/L) were the strongest indicators of disinfection performance for source waters of variable TOC, however site-specific testing may be needed to apply this framework. Challenge testing with influent nitrite indicated that ozone disinfection performance is significantly impacted (>50% reduction in inactivation) in the presence of nitrite thus enforcing the importance of accounting for this value in the applied ozone dose. Multi-point ozone dissolution was investigated as an alternative ozone application method that may present a benefit with respect to overall disinfection performance especially if nitrite was present. Developing and validating these alternative monitoring frameworks and ozone application methods is imperative in water reuse applications where unnecessary elevated ozone exposure may lead to harmful byproduct formation.
Electron beam (e-beam) treatment uses accelerated electrons to form oxidizing and reducing radicals when applied to water without the use of external chemicals. In this study, electron beam treatment was used to degrade 1,4-dioxane in several water matrices. Removal improved in the progressively cleaner water matrices and removals as high as 94% to 99% were observed at a dose of 2.3 kGy in secondary effluent. 1,4-dioxane removal was confirmed to be primarily through hydroxyl radical oxidation. The calculated electrical energy per order was found to be 0.53, 0.26, and 0.08 kWh/m3/order for secondary effluent (Avg. total organic carbon (TOC) 9.25 mg/L), granular activated carbon effluent (TOC 3.46 mg/L), and ultrapure water, respectively, with a 70% generation and transfer efficiency applied.
In the present study, a novel pilot ozone contactor configuration was employed using hydrogen peroxide (H 2 O 2 ) and multiple ozone diffusion zones in an over-under contactor to reduce bromate formation in three wastewater effluents.