Frank Vizesi

Frank Vizesi

Auto-generated profile, based on publicly available information

Frank Vizesi

SeaSpine Inc., Carlsbad, CA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2020 in Frontiers in Surgery
Verified
Journal Article
Open access
PDF file
NRNicholas Russell
Nicholas Russell
WWWilliam R. Walsh
William R. Walsh
VLVedran Lovric
Vedran Lovric
PKPeter Kim
Peter Kim
JCJennifer H. Chen
Jennifer H. Chen
FVFrank Vizesi
Frank Vizesi
Introduction: Demineralized bone matrix (DBM) is a widely used bone graft in spinal fusion. Most commercial DBMs are composed of demineralized bone particles (~125–800 microns) suspended in a carrier that provides improved handling but dilutes the osteoinductive component. DBM fibers (DBF) provide improved osteoconductivity and do not require a carrier. It has been suggested that 100% DBF may offer improved performance over particulate-based DBMs with carrier. Study Design: Seven commercially available DBM products were tested in an athymic rat posterolateral fusion model. There were four 100% DBFs, two DBFs containing a carrier, and one particulate-based DBM containing carrier. Objective: The study objectives were to evaluate the in vivo performance: (1) compare fusion rate and fusion maturity of six commercially available DBFs and one particulate-based DBM, and (2) assess the effect of carrier on fusion outcomes for DBFs in a posterolateral fusion model. Methods: The DBF/DBM products evaluated were: StrandTM Family, Propel® DBM Fibers, Vesuvius® Demineralized Fibers, Optium® DBM Putty, Grafton® DBF, Grafton Flex, and DBX® Putty. Single-level posterolateral fusion was performed in 69 athymic rats. Fusion was assessed bilaterally after 4 weeks by manual palpation, radiograph and CT for bridging bone. Fusion mass maturity was assessed with a CT maturity grading scale and by histology. Statistical analysis was performed using Fishers Exact Test for categorical data and Kruskal-Wallis Test for non-parametric data. Results: Strand Family achieved 100% fusion (18/18) by manual palpation, radiographic and CT evaluation, significantly higher than Propel Fibers, Vesuvius Fibers, Optium Putty, and DBX Putty, and not statistically higher than Grafton DBF and Grafton Flex. Strand Family provided the highest fusion maturity, with CT maturity grade of 2.3/3.0 and 89% mature fusion rate. Fusion results suggest a detrimental effect of carrier on fusion performance. Conclusions: There were large variations in fusion performance for seven commercially available DBM products in an established preclinical fusion model. There were even significant differences between different 100% DBF products, suggesting that composition alone does not guarantee in vivo performance. In the absence of definitive clinical evidence, surgeons should carefully consider available data in valid animal models when selecting demineralized allograft options.

20 October 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
AAAidin Abedi
Aidin Abedi
BFBlake Formanek
Blake Formanek
NRNicholas Russell
Nicholas Russell
FVFrank Vizesi
Frank Vizesi
SBScott D. Boden
Scott D. Boden
ZBZorica Buser
Zorica Buser
Background: Despite the extensive use of cellular bone matrices (CBMs) in spine surgery, there is little evidence to support the contribution of cells within CBMs to bone formation. The objective of this study was to determine the contribution of cells to spinal fusion by direct comparisons among viable CBMs, devitalized CBMs, and cell-free demineralized bone matrix (DBM). Methods: Three commercially available grafts were tested: a CBM containing particulate DBM (CBM-particulate), a CBM containing DBM fibers (CBM-fiber), and a cell-free product with DBM fibers only (DBM-fiber). CBMs were used in viable states (CBM-particulatev and CBM-fiberv) and devitalized (lyophilized) states (CBM-particulated and CBM-fiberd), resulting in 5 groups. Viable cell counts and bone morphogenetic protein-2 (BMP-2) content on enzyme-linked immunosorbent assay (ELISA) within each graft material were measured. A single-level posterolateral lumbar fusion was performed on 45 athymic rats with 3 lots of each product implanted into 9 animals per group. After 6 weeks, fusion was assessed using manual palpation, micro-computed tomography (μ-CT), and histological analysis. Results: The 2 groups with viable cells were comparable with respect to cell counts, and pairwise comparisons showed no significant differences in BMP-2 content across the 5 groups. Manual palpation demonstrated fusion rates of 9 of 9 in the DBM-fiber specimens, 9 of 9 in the CBM-fiberd specimens, 8 of 9 in the CBM-fiberv specimens, and 0 of 9 in both CBM-particulate groups. The μ-CT maturity grade was significantly higher in the DBM-fiber group (2.78 ± 0.55) compared with the other groups (p < 0.0001), while none of the CBM-particulate samples demonstrated intertransverse fusion in qualitative assessments. The viable and devitalized samples in each CBM group were comparable with regard to fusion rates, bone volume fraction, μ-CT maturity grade, and histological features. Conclusions: The cellular component of 2 commercially available CBMs yielded no additional benefits in terms of spinal fusion. Meanwhile, the groups with a fiber-based DBM demonstrated significantly higher fusion outcomes compared with the CBM groups with particulate DBM, indicating that the DBM component is probably the key determinant of fusion. Clinical Relevance: Data from the current study demonstrate that cells yielded no additional benefit in spinal fusion and emphasize the need for well-designed clinical studies on cellular graft materials.

22 March 2016 in The Open Orthopaedics Journal
Verified
Journal Article
Open access
PDF file
CVChristopher J. Vertullo
Christopher J. Vertullo
DZDavid Zbrojkiewicz
David Zbrojkiewicz
FVFrank Vizesi
Frank Vizesi
WWWilliam Walsh
William Walsh
Thermal Analysis of the Tibial Cement Interface with Modern Cementing Technique

1 November 2020 in The Spine Journal
Verified
Journal Article
Open access
WWWilliam Walsh
William Walsh
MPMatthew Henry Pelletier
Matthew Henry Pelletier
DWDan Wills
Dan Wills
TWTian Wang
Tian Wang
SBShaeffer Bannigan
Shaeffer Bannigan
FVFrank Vizesi
Frank Vizesi
The interface and interactions between an interbody cage, graft material and host bone can all participate in the fusion. Shortcomings of PEEK interbody cages have been addressed with novel titanium surfaces. Titanium surfaces paired with macro-scale topography features on the endplates and within the aperture may provide additional benefits. To evaluate the influence of cage design parameters on interbody fusion in a large animal pre-clinical model. A comparative preclinical large animal model was performed to evaluate how macroscale topography features of an interbody cage can facilitate early integration between the host bone, graft material, and interbody cage and these effects on biomechanical stability and fusion. Forty single level interbody fusions (L4-5) using iliac crest autograft and bilateral pedicle screw fixation were performed in adult sheep to evaluate the effect of undercut macrostructure topography features of an interbody cage on the endplates and within the aperture. Fusions were evaluated at 6 and 12 weeks (n=10 per group) using radiography, microcomputed tomography, biomechanical integrity and histology endpoints. The presence of the undercut macrostructures present on the endplates and within the aperture statistically improved biomechanical integrity at 6 and 12 weeks compared to controls. Microcomputed tomography and histology demonstrated bony interdigitation within the endplate and aperture features contributing to the improvement in properties. The current study demonstrates that PEEK implants with titanium surfaces can be augmented by undercut macrostructures present on the endplates and within the aperture to provide opportunities for a series of anchoring points that, with new bone formation and remodelling, result in earlier and improved biomechanical integrity of the treated level. This preclinical study showed that bone interdigitation with the undercut macrostructures present on the endplates and within the aperture resulted in improved fusion and biomechanical stability in a clinically relevant spinal fusion model. Future clinical study is warranted to evaluate such implants' performance in humans.

20 April 2023 in Spine
Verified
Journal Article
Open access
JLJeremy A. Lombardo
Jeremy A. Lombardo
NRNick Russell
Nick Russell
JHJiawei He
Jiawei He
MLMichael J. Dvm Larson
Michael J. Dvm Larson
WWWilliam Walsh
William Walsh
FVFrank Vizesi
Frank Vizesi
Study Design.: Controlled animal study. Objective.: To assess the cellular contribution of autograft to spinal fusion and determine the effects of intraoperative storage conditions on fusion. Summary of Background Data.: Autograft is considered the gold standard graft material in spinal fusion, purportedly due to its osteogenic properties. Autograft consists of adherent and non-adherent cellular components within a cancellous bone scaffold. However, neither the contribution of each component to bone healing is well understood nor are the effects of intraoperative storage of autograft. Materials and Methods.: Posterolateral spinal fusion was performed in 48 rabbits. Autograft groups evaluated included: (1) Viable, (2) partially devitalized, (3) devitalized, (4) dried, and (5) hydrated iliac crest. Partially devitalized and devitalized grafts were rinsed with saline, removing nonadherent cells. Devitalized graft was, in addition, freeze/thawed, lysing adherent cells. For 90 minutes before implantation, air dried iliac crest was left on the back table whereas the hydrated iliac crest was immersed in saline. At 8 weeks, fusion was assessed through manual palpation, radiography, and microcomputed tomography. In addition, the cellular viability of cancellous bone was assayed over 4 hours. Results.: Spinal fusion rates by manual palpation were not statistically different between viable (58%) and partially devitalized (86%) autografts (P = 0.19). Both rates were significantly higher than devitalized and dried autograft (both 0%, P < 0.001). In vitro bone cell viability was reduced by 37% after 1 hour and by 63% after 4 hours when the bone was left dry (P < 0.001). Bone cell viability and fusion performance (88%, P < 0.001 vs. dried autograft) were maintained when the graft was stored in saline. Conclusions.: The cellular component of autograft is important for spinal fusion. Adherent graft cells seem to be the more important cellular component in the rabbit model. Autograft left dry on the back table showed a rapid decline in cell viability and fusion but was maintained with storage in saline.

2 February 2023 in The Spine Journal
Verified
Journal Article
Open access
GMGregory M. Mundis
Gregory M. Mundis
EOEric C. Olsson
Eric C. Olsson
RHRobert A. Hart
Robert A. Hart
SWSeth K. Williams
Seth K. Williams
RMRyan Martyn
Ryan Martyn
FVFrank Vizesi
Frank Vizesi
Lateral mass screw fixation is the standard for posterior subaxial cervical fixation. Several freehand surgical techniques for placing lateral mass screws have been described which rely on anatomical landmarks and surgeon mastery of the technique to safely place screws. The accuracy of these freehand techniques is inherently variable and can be influenced by a surgeon's level of clinical experience. A novel technique was developed that utilizes the plane of the facet joint to create lateral mass screw pilot holes parallel with the joint line to improve the safety and accuracy of lateral mass screw placement regardless of experience. To assess the safety and accuracy of lateral mass screw placement using a novel lateral mass drill guide instrument (LM Guide), compared to standard freehand technique. Randomized cadaveric study utilizing multiple surgeon evaluators to compare the safety and accuracy of guided cervical lateral mass placement compared to traditional freehand techniques. Lateral mass screws were placed from C3 to C7 in 20 cadaver specimens by 8 spine surgeons of varying levels of clinical experience (4 attendings, 4 fellows). Screws were placed bilaterally using standard anatomic landmarks ("freehand") randomly allocated on one side and using the LM Guide on the other. Cadaveric specimens were imaged with high-resolution CT to assess screw placement. Zone grading for safety was conducted based on screw tip position and clinical severity of screw breach was based on proximity to surrounding neurovascular anatomy. Screws were graded as safe, at-risk, or critical, with at-risk and critical screws considered malpositioned. To assess the accuracy of screw trajectory placed using the LM Guide compared to freehand, sagittal screw angle was measured and compared to an "ideal" screw path parallel to the facet joint line. Freehand and LM Guide groups were compared using Pearson's chi-square correlation. Screw placement using the LM guide yielded a significantly lower rate of screw malpositioning, with 7 of 91 (7.7%) compared with 18 of 99 (18.2%) screws placed in the At-Risk or Critical Zones, p<.05. Of the 91 screws inserted using the LM Guide, 84 (92.3%) were in the Safe Zone, 7 (7.7%) were At-Risk, and 0 were in Critical zones. There was no incidence of neural or transverse foramen breaches with the LM Guide. In comparison, for the 99 screws inserted freehand, 81 (81.8%) were Safe, 14 (14.1%) were At-Risk, and 4 (4.1%) were in Critical zones. The 4 Critical zone freehand screw breaches included 1 neural foramen breach, 2 transverse foramen breaches, and 1 facet breach. The LM Guide also resulted in higher accuracy of screw trajectory, as indicated by a significant reduction in sagittal screw angle compared with freehand, p<.01. Notably, in the less-experienced surgeon cohort, the LM Guide significantly reduced the sagittal screw angle and resulted in no critical screw breaches compared to 3 critical breaches with freehand technique suggesting there might be a benefit in decreasing the learning curve associated with lateral mass screw placement. Lateral mass screw placement with a novel LM Guide that uses the facet joint to control screw trajectory improved the accuracy and reproducibility of screw placement with a significant reduction in screw breach rate and sagittal screw angle compared to freehand techniques regardless of surgeon experience level. The inherent variability of freehand lateral mass screw placement can increase the risk of clinical complications associated with screw malpositioning. The technique presented in this cadaveric study may be a viable alternative to standard freehand technique that can improve the overall safety of lateral mass screw placement.