Francesca Bennet

Francesca Bennet

Auto-generated profile, based on publicly available information

Francesca Bennet

Federal Institute for Risk Assessment 1 , Max-Dohrn-Strasse 8-10, Berlin 10589, Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2021 in ChemElectroChem
Verified
Journal Article
Open access
PDF file
SHSoraya Höfs
Soraya Höfs
DHDeniz Hülagü
Deniz Hülagü
FBFrancesca Bennet
Francesca Bennet
PCPeter Carl
Peter Carl
SFSabine Flemig
Sabine Flemig
Rudolf J. SchneiderRudolf J. Schneider
Rudolf J. Schneider
Electrochemical methods offer great promise in meeting the demand for user‐friendly on‐site devices for monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme‐linked immunosorbent assays, with photometric detection of 3,3’,5,5’‐tetramethylbenzidine (TMB), form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detection step, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphone‐based, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis for sensing of further analytes.

1 June 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
FBF Bennet
F Bennet
LBLoïc Burr
Loïc Burr
DSDavid Schmid
David Schmid
VHVasile-Dan Hodoroaba
Vasile-Dan Hodoroaba
As part of the development of a library of accurate and efficient methods for measurement of nanoparticle properties, we develop and optimize a method for the efficient analysis of nanoparticle size distribution from suspensions via microprinting and digital analysis of electron microscopy (SEM and TEM) images, with the ultimate aim of automated quantitative concentration analysis (calculated from drop volume). A series of different nanoparticle suspensions (gold, latex, and SiO2 in varying sizes and concentrations) were printed onto TEM grids in a 4 x 4 array in the concentration range 7×108 to 1×1011 nanoparticles/mL and imaged with SEM. Concentrations and printing conditions (temperature, relative humidity) were varied in order to minimize the coffee-ring effect.

16 August 2023 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
FBFrancesca Bennet
Francesca Bennet
RORobert Opitz
Robert Opitz
NGNarges Ghoreishi
Narges Ghoreishi
KPKristina Plate
Kristina Plate
JBJean-Paul Barnes
Jean-Paul Barnes
JRJorg Radnik
Jorg Radnik
Due to the extremely high specific surface area of nanoparticles and corresponding potential for adsorption, the results of surface analysis can be highly dependent on the history of the particles, particularly regarding sample preparation and storage. The sample preparation method has, therefore, the potential to have a significant influence on the results. This report describes an interlaboratory comparison (ILC) with the aim of assessing which sample preparation methods for ToF-SIMS analysis of nanoparticles provided the most intra- and interlaboratory consistency and the least amount of sample contamination. The BAM reference material BAM-P110 (TiO2 nanoparticles with a mean Feret diameter of 19 nm) was used as a sample representing typical nanoparticles. A total of 11 participants returned ToF-SIMS data, in positive and (optionally) negative polarity, using sample preparation methods of “stick-and-go” as well as optionally “drop-dry” and “spin-coat.” The results showed that the largest sources of variation within the entire data set were caused by adventitious hydrocarbon contamination or insufficient sample coverage, with the spin-coating protocol applied in this ILC showing a tendency toward insufficient sample coverage; the sample preparation method or the participant had a lesser influence on results.