David Schmid

Mr. David Schmid

Swiss Center for Electronics and Microtechnology (Switzerland), Neuchâtel, Switzerland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Molecules
Verified
Journal Article
Open access
PDF file
JRJorg Radnik
Jorg Radnik
VHVasile-Dan Hodoroaba
Vasile-Dan Hodoroaba
HJHarald Jungnickel
Harald Jungnickel
JTJutta Tentschert
Jutta Tentschert
ALAndreas Luch
Andreas Luch
Eugenia Valsami-JonesEugenia Valsami-Jones
Eugenia Valsami-Jones
Whereas the characterization of nanomaterials using different analytical techniques is often highly automated and standardized, the sample preparation that precedes it causes a bottleneck in nanomaterial analysis as it is performed manually. Usually, this pretreatment depends on the skills and experience of the analysts. Furthermore, adequate reporting of the sample preparation is often missing. In this overview, some solutions for techniques widely used in nano-analytics to overcome this problem are discussed. Two examples of sample preparation optimization by automation are presented, which demonstrate that this approach is leading to increased analytical confidence. Our first example is motivated by the need to exclude human bias and focuses on the development of automation in sample introduction. To this end, a robotic system has been developed, which can prepare stable and homogeneous nanomaterial suspensions amenable to a variety of well-established analytical methods, such as dynamic light scattering (DLS), small-angle X-ray scattering (SAXS), field-flow fractionation (FFF) or single-particle inductively coupled mass spectrometry (sp-ICP-MS). Our second example addresses biological samples, such as cells exposed to nanomaterials, which are still challenging for reliable analysis. An air–liquid interface has been developed for the exposure of biological samples to nanomaterial-containing aerosols. The system exposes transmission electron microscopy (TEM) grids under reproducible conditions, whilst also allowing characterization of aerosol composition with mass spectrometry. Such an approach enables correlative measurements combining biological with physicochemical analysis. These case studies demonstrate that standardization and automation of sample preparation setups, combined with appropriate measurement processes and data reduction are crucial steps towards more reliable and reproducible data.

1 September 2021 in Molecules
Verified
Journal Article
Open access
PDF file
RPRuud Peters
Ruud Peters
IEIngrid Elbers
Ingrid Elbers
AUAnna Undas
Anna Undas
ESEelco Sijtsma
Eelco Sijtsma
SBSophie Marie Briffa
Sophie Marie Briffa
Eugenia Valsami-JonesEugenia Valsami-Jones
Eugenia Valsami-Jones
ACEnano is an EU-funded project which aims at developing, optimising and validating methods for the detection and characterisation of nanomaterials (NMs) in increasingly complex matrices to improve confidence in the results and support their use in regulation. Within this project, several interlaboratory comparisons (ILCs) for the determination of particle size and concentration have been organised to benchmark existing analytical methods. In this paper the results of a number of these ILCs for the characterisation of NMs are presented and discussed. The results of the analyses of pristine well-defined particles such as 60 nm Au NMs in a simple aqueous suspension showed that laboratories are well capable of determining the sizes of these particles. The analysis of particles in complex matrices or formulations such as consumer products resulted in larger variations in particle sizes within technologies and clear differences in capability between techniques. Sunscreen lotion sample analysis by laboratories using spICP-MS and TEM/SEM identified and confirmed the TiO2 particles as being nanoscale and compliant with the EU definition of an NM for regulatory purposes. In a toothpaste sample orthogonal results by PTA, spICP-MS and TEM/SEM agreed and stated the TiO2 particles as not fitting the EU definition of an NM. In general, from the results of these ILCs we conclude that laboratories are well capable of determining particle sizes of NM, even in fairly complex formulations.

1 June 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
FBF Bennet
F Bennet
LBLoïc Burr
Loïc Burr
DSDavid Schmid
David Schmid
VHVasile-Dan Hodoroaba
Vasile-Dan Hodoroaba
As part of the development of a library of accurate and efficient methods for measurement of nanoparticle properties, we develop and optimize a method for the efficient analysis of nanoparticle size distribution from suspensions via microprinting and digital analysis of electron microscopy (SEM and TEM) images, with the ultimate aim of automated quantitative concentration analysis (calculated from drop volume). A series of different nanoparticle suspensions (gold, latex, and SiO2 in varying sizes and concentrations) were printed onto TEM grids in a 4 x 4 array in the concentration range 7×108 to 1×1011 nanoparticles/mL and imaged with SEM. Concentrations and printing conditions (temperature, relative humidity) were varied in order to minimize the coffee-ring effect.

25 November 2025 in Nature Communications
Verified
Journal Article
Open access
JBJames Bourely
James Bourely
NFNicolas Fumeaux
Nicolas Fumeaux
XAXavier Aeby
Xavier Aeby
JKJaemin Kim
Jaemin Kim
GSGilberto Siqueira
Gilberto Siqueira
DBDanick Briand
Danick Briand
Temperature monitoring within the cold chain, essential for safety of perishable products, typically employs devices such as battery-powered data loggers and radio-frequency identification tags. Such devices include non-eco-friendly components, posing challenges for their safe disposal and recycling. This study demonstrates the fabrication of a fully ecoresorbable, chipless, and wireless temperature-responsive tag, designed to irreversibly track temperature changes through a permanent shift in resonance frequency. The tag is printed on a customized moisture-resistant poly(β-hydroxybutyrate)-cellulose composite substrate. An RLC circuit made of printed zinc metallic traces, encapsulated with beeswax to prevent oxidation, enables seamless wireless operation. The tag utilizes bio-based phase-changing materials such as frozen olive, jojoba, and coconut oils to induce irreversible resonance frequency shifts of more than 30 MHz at respective melting points of 8 °C, 15 °C, and 25 °C. A cellulose capillary element efficiently absorbs the melted oil, enabling reliable operation at inclinations from 0° to 90°. At the end of its service life, the device can undergo disintegration in a compost environment within 9 weeks. This work demonstrates a sustainable chipless technology from material selection and manufacturing processes to end-of-life disposal as an advanced thermal indicator solution for cold chain temperature-excursion detection.

29 July 2022 in Molecules
Verified
Journal Article
Open access
PDF file
RPRuud Peters
Ruud Peters
IEIngrid Elbers
Ingrid Elbers
AUAnna Undas
Anna Undas
ESEelco Sijtsma
Eelco Sijtsma
SBSophie Marie Briffa
Sophie Marie Briffa
Eugenia Valsami-JonesEugenia Valsami-Jones
Eugenia Valsami-Jones
Due to miscommunication a number of potential co-authors were not listed in the original publication

22 March 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
JBJames Bourely
James Bourely
JKJaemin Kim
Jaemin Kim
XAXavier Aeby
Xavier Aeby
GSGilberto Siqueira
Gilberto Siqueira
GNGustav Nyström
Gustav Nyström
DBDanick Briand
Danick Briand
Aiming to reduce electronic waste in sensing applications, we report on an eco-friendly printed microstrip line to sense relative humidity (RH) and temperature. The device is made of zinc resonators on paper used as transducers, which are coated with beeswax as an encapsulant, and uses konjac as a humidity sensitive coating. The multi-resonating structure, operating in the S-band, shows reproducible temperature and humidity sensing from 15 °C to 35 °C and 30% to 70% RH with sensitivities up to 1.9 MHz/°C and 2.0 MHz/%RH, respectively. This combination of transducing and sensing materials is promising for the realization of disposable environmental sensors.