Satish B. Alapati

Satish B. Alapati

Auto-generated profile, based on publicly available information

Satish B. Alapati

Department of Endodontics, University of Illinois at Chicago, Chicago, Illinois

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Biomaterials
Verified
Journal Article
Closed access
CHChun-Chieh Huang
Chun-Chieh Huang
RNRaghuvaran Narayanan
Raghuvaran Narayanan
SASatish Alapati
Satish Alapati
Sriram RavindranSriram Ravindran
Sriram Ravindran

1 January 2005 in Journal of Endodontics
Verified
Journal Article
Closed access
PDF file
SASatish B. Alapati
Satish B. Alapati
William BrantleyWilliam Brantley
William Brantley
TSTimothy A. Svec
Timothy A. Svec
JPJohn M. Powers
John M. Powers
JNJohn M. Nusstein
John M. Nusstein
Glenn S. DaehnGlenn S. Daehn
Glenn S. Daehn
Numerous discarded ProFile GT, ProFile, and ProTaper nickel-titanium rotary instruments obtained from two graduate endodontic clinics were examined by scanning electron microscopy. These instruments had an unknown history of clinical use and had fractured or experienced considerable permanent torsional deformation without complete separation. The failure processes generally exhibited substantial ductile character, evidenced by a dimpled rupture fracture surface. Crack propagation at grain boundaries and cleavage surfaces indicative of transgranular fracture were observed for some specimens. It appeared that oxide particles from the manufacturing process served as nucleating sites for the microvoids, leading to dimpled rupture. A previously unreported fracture mode also was observed, in which crack propagation, approximately parallel to the local flute orientation, connected pitted regions on the surface. Combining present and previous scanning electron microscopy observations of clinically failed instruments, suggestions are offered for improving their fracture resistance.

1 November 2009 in Journal of Endodontics
Verified
Journal Article
Closed access
SASatish B. Alapati
Satish B. Alapati
WBWilliam A. Brantley
William A. Brantley
MIMasahiro Iijima
Masahiro Iijima
WCWilliam A.T. Clark
William A.T. Clark
LKLibor Kovarik
Libor Kovarik
WJWilliam Ben Johnson
William Ben Johnson

1 October 2003 in Journal of Endodontics
Verified
Journal Article
Closed access
PDF file
SASatish B. Alapati
Satish B. Alapati
WBWilliam A. Brantley
William A. Brantley
TSTimothy A. Svec
Timothy A. Svec
JPJohn M. Powers
John M. Powers
JMJohn C. Mitchell
John C. Mitchell
The appearances of the tip sections of ProFile 0.04 taper and Lightspeed 25-mm long, ISO size 25, nickel-titanium rotary instruments were compared with a scanning electron microscope in the as-received condition and after one, three, and six simulated clinical uses to prepare mesial canals of extracted mandibular molars. For the used ProFile instruments, there was some flattening of the characteristic material rollover and minor apparent wear at the edges of the flutes, but there was little change in the tip regions of the used Lightspeed instruments. Deposits on the surfaces of the instruments were attributed to the manufacturing processes and the in vitro preparation of root canals in the extracted teeth. The simulated clinical use did not cause substantial changes in the regions of these two brands of rotary instruments that are involved in the clinical preparation of root canals.

1 March 2012 in The Angle Orthodontist
Verified
Journal Article
Closed access
MIMasahiro Iijima
Masahiro Iijima
TMTakeshi Muguruma
Takeshi Muguruma
WBWilliam Brantley
William Brantley
HCHan-Cheol Choe
Han-Cheol Choe
SNSusumu Nakagaki
Susumu Nakagaki
IMItaru Mizoguchi
Itaru Mizoguchi
Objective: To determine the effect of coating on the properties of two esthetic orthodontic nickel-titanium wires. Materials and Methods: Woowa (polymer coating; Dany Harvest) and BioForce High Aesthetic Archwire (metal coating; Dentsply GAC) with cross-section dimensions of 0.016 × 0.022 inches were selected. Noncoated posterior regions of the anterior-coated Woowa and uncoated Sentalloy were used for comparison. Nominal coating compositions were determined by x-ray fluorescence (JSX-3200, JOEL). Cross-sectioned and external surfaces were observed with a scanning electron microscope (SEM; SSX-550, Shimadzu) and an atomic force microscope (SPM-9500J2, Shimadzu). A three-point bending test (12-mm span) was carried out using a universal testing machine (EZ Test, Shimadzu). Hardness and elastic modulus of external and cross-sectioned surfaces were obtained by nanoindentation (ENT-1100a, Elionix; n = 10). Results: Coatings on Woowa and BioForce High Aesthetic Archwire contained 41% silver and 14% gold, respectively. The coating thickness on Woowa was approximately 10 µm, and the coating thickness on BioForce High Aesthetic Archwire was much smaller. The surfaces of both coated wires were rougher than the noncoated wires. Woowa showed a higher mean unloading force than the noncoated Woowa, although BioForce High Aesthetic Archwire showed a lower mean unloading force than Sentalloy. While cross-sectional surfaces of all wires had similar hardness and elastic modulus, values for the external surface of Woowa were smaller than for the other wires. Conclusions: The coating processes for Woowa and BioForce High Aesthetic Archwire influence bending behavior and surface morphology.

1 June 2008 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
ZYZeynep YEŞİL
Zeynep YEŞİL
SASatish Alapati
Satish Alapati
WJWilliam Johnston
William Johnston
RSRobert R. Seghi
Robert R. Seghi