Arif Hepbasli

Arif Hepbasli

Auto-generated profile, based on publicly available information

Arif Hepbasli

Department of Mechanical Engineering, Faculty of Engineering, Ege University, TR-35100 Bornova, Izmir, Turkey

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2009 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
MBM. Tolga Balta
M. Tolga Balta
IDIbrahim Dincer
Ibrahim Dincer
AHArif Hepbasli
Arif Hepbasli
Geothermal‐based hydrogen production, which basically uses geothermal energy for hydrogen production, appears to be an environmentally conscious and sustainable option for the countries with abundant geothermal energy resources. In this study, four potential methods are identified and proposed for geothermal‐based hydrogen production, namely: (i) direct production of hydrogen from the geothermal steam, (ii) through conventional water electrolysis using the electricity generated through geothermal power plant, (iii) by using both geothermal heat and electricity for high temperature steam electrolysis and/or hybrid processes, and (iv) by using the heat available from geothermal resource in thermochemical processes. Nowadays, most researches are focused on high‐temperature electrolysis and thermochemical processes. Here we essentially discuss some potential low‐temperature thermochemical and hybrid cycles for geothermal‐based hydrogen production, due to their wider practicality, and examine them as a sustainable option for hydrogen production using geothermal heat. We also assess their thermodynamic performance through energy and exergy efficiencies. The results show that these cycles have good potential and attractive overall system efficiencies over 50% based on a complete reaction approach. The copper‐chlorine cycle is identified as a highly promising cycle for geothermal‐hydrogen production. Copyright © 2009 John Wiley & Sons, Ltd.

8 September 2006 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
EKEbru Hancioglu Kuzgunkaya
Ebru Hancioglu Kuzgunkaya
AHArif Hepbasli
Arif Hepbasli
This paper is concerned with the exergy analysis of the single layer drying process of laurel leaves in a ground-source heat pump drying cabinet, which was designed and constructed in the Solar Energy Institute, Ege University, Izmir, Turkey. The effects of drying air temperature on exergy losses, exergy efficiencies and exergetic improvement potential of the drying process are investigated. The results have indicated that exergy efficiencies of the dryer increase with rising the drying air temperature. Moreover, the laurel leaves are sufficiently dried at the temperatures ranging from 40 to 50°C with relative humidities varying from 16 to 19% and a drying air velocity of 0.5 m s−1 during the drying period of 9 h. The exergy efficiency values are obtained to range from 81.35 to 87.48% based on the inflow, outflow and loss of exergy, and 9.11 to 15.48% based on the product/fuel basis between the same drying air temperatures with a drying air mass flow rate of 0.12 kg s−1. Copyright © 2006 John Wiley & Sons, Ltd.

14 December 2006 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
AHArif Hepbasli
Arif Hepbasli
This study deals with thermoeconomic analysis of household refrigerators for providing useful insights into the relations between thermodynamics and economics. In the analysis, the EXCEM method based on the quantities exergy, cost, energy and mass is applied to a household refrigerator using the refrigerant R134a. The performance evaluation of the refrigerator is conducted in terms of exergoeconomic aspects based on the various reference state temperatures ranging from 0 to 20°C. The exergy destructions in each of the components of the overall system are determined for average values of experimentally measured parameters. Exergy efficiencies of the system components are determined to assess their performances and to elucidate potentials for improvement. Thermodynamic loss rate-to-capital cost ratios for each components of the refrigerator are investigated. Correlations are developed to estimate exergy efficiencies and ratios of exergy loss rate-to-capital cost as a function of reference (dead) state temperature. The ratios of exergy loss rates to capital cost values are obtained to vary from 2.949 × 10−4 to 3.468 × 10−4 kW US$−1. The exergy efficiency values are also found to range from 13.69 to 28.00% and 58.15 to 68.88% on the basis of net rational efficiency and product/fuel at the reference state temperatures considered, respectively. It is expected that the results obtained will be useful to those involved in the development of analysis and design methodologies that integrate thermodynamics and economics. Copyright © 2006 John Wiley & Sons, Ltd.

8 June 2009 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
YYYilmaz Yoru
Yilmaz Yoru
TKTahir Hikmet Karakoç
Tahir Hikmet Karakoç
AHArif Hepbasli
Arif Hepbasli
The study deals with the energetic and exergetic analyses of a cogeneration (combined heat and power, CHP) system installed in a ceramic factory, located in Izmir, Turkey. This system has three gas turbines with a total capacity of 13 MW, six spray dryers and two heat exchangers. In the analysis, actual operational data over one-month period are utilized. The so-called CogeNNexT code is written in C++ and developed to analyze energetic and exergetic data from a database. This code is also used to analyze turbines, spray dryers and heat exchangers in this factory. Specifications of some parts of system components have been collected from the factory. Based on the 720 h data pattern (including 43 200 data), the mean energetic and exergetic efficiency values of the cogeneration system are found to be 82.3 and 34.7%, respectively. Copyright © 2009 John Wiley & Sons, Ltd.

11 May 2009 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
Zafer ErbayZafer Erbay
Zafer Erbay
FIFiliz Içier
Filiz Içier
AHArif Hepbasli
Arif Hepbasli
In this study, olive leaves were dried in a pilot-scale heat pump (HP) belt conveyor dryer as a thin layer. Drying experiments were carried out at the drying air temperature range of 45–55°C with the drying air velocity range of 0.5–1.5 m s−1. The performance of the system and the process was evaluated using exergy analysis method. The exergy loss and flow diagram (the so-called Grassmann diagram) of the dryer system was presented to give quantitative information regarding the proportion of the exergy input that is dissipated in the various system components. Effects of the drying air temperature and the velocity on the performance of the drying process were discussed. The actual coefficient of performance values were obtained to be 2.37 for the HP unit and 2.31 for the overall system, respectively. The most important component of the system for improving the efficiency was determined to be the compressor. Exergetic efficiencies of the drying of olive leaves were in the range of 67.45–81.95%. It was obtained that they increased as the drying air temperature decreased and the drying air velocity increased. Copyright © 2009 John Wiley & Sons, Ltd.

3 October 2011 in Drying Technology
Verified
Journal Article
Closed access
ZUZafer UTLU
Zafer UTLU
AHArif Hepbasli
Arif Hepbasli
MTMuharrem Turan
Muharrem Turan
In recent years, exergy analysis has been widely used in the design, operation, and performance assessment of various thermal systems, among which drying, which is an energy intensive operation, is of a great importance. In the ceramic industry, it is aimed at utilizing a minimum amount of energy in order to remove the maximum moisture for the desired final conditions of the product to be dried. In this study, energy and exergy analyses of a ceramic plant, located in Izmir, Turkey, with a yearly production capacity of 24 million m2 were performed using the actual operational data over a period of 12 months. The drying system at the three stages was analyzed and the values for exergy destruction and efficiency for each component of the system and the whole system at a reference (dead state) temperature of 22°C were calculated. For the month of January, energy and exergy efficiencies for the spray dryer (SD) were determined to be 65.50 and 53.7%, respectively. Energy and exergy efficiency values of the vertical dryer (VD) were 45.12 and 43.3%, respectively, and those of the furnace (F) were 35.08 and 16%, respectively. Based on this one-year assessment, the energy efficiency values for the SD, VD, and F varied between 58.48 and 65.50%, 42.44 and 50.87%, and 30.44 and 36.99%, and the exergy efficiency values were in the range of 44.85–65.16%, 34.92–45.42%, and 12.73–16.41%, respectively.