Francesco Digeronimo

Francesco Digeronimo

Auto-generated profile, based on publicly available information

Francesco Digeronimo

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Ireland; Discipline of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Ireland

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2024 in Biomedical Materials
Verified
Journal Article
Open access
CDConor Darroch
Conor Darroch
FDFrancesco Digeronimo
Francesco Digeronimo
GAGiuseppe Asaro
Giuseppe Asaro
MMManon Minsart
Manon Minsart
NPNele Pien
Nele Pien
MMMichael Monaghan
Michael Monaghan
Melt electrowriting (MEW) is an additive manufacturing technique that harnesses electro-hydrodynamic phenomena to produce 3D-printed fibres with diameters on the scale of 10s of microns. The ability to print at this small scale provides opportunities to create structures with incredibly fine resolution and highly defined morphology. The current gold standard material for MEW is poly(ϵ-caprolactone) (PCL), a polymer with excellent biocompatibility but lacking in chemical groups that can allow intrinsic additional functionality. To provide this functionality while maintaining PCL’s positive attributes, blending was performed with a Poly(Ethylene Glycol) (PEG)-based Acrylate endcapped Urethane-based Precursor (AUP). AUPs are a group of polymers, built on a backbone of existing polymers, which introduce additional functionality by the addition of one or more acrylate groups that terminate the polymer chain of a backbone polymer. By blending with a 20kDa AUP-PEG in small amounts, it is shown that MEW attributes are preserved, producing high-quality meshes. Blends were produced in various PCL:AUP weight ratios (100:0, 90:10 and 0:100) and processed into both solvent-cast films and MEW meshes that were used to characterise the properties of the blends. It was found that the addition of AUP-PEG to PCL significantly increases the hydrophilicity of structures produced with these polymers, and adds swelling capability compared to the non-swelling PCL. The developed blend (90:10) is shown to be processable using MEW, and the quality of manufactured scaffolds is evaluated against pure PCL scaffolds by performing scanning electron microscopy image analysis, with the quality of the novel MEW blend scaffolds showing comparable quality to that of pure PCL. The presence of the functionalisable AUP material on the surface of the developed scaffolds is also confirmed using fluorescence labelling of the acrylate groups. Biocompatibility of the MEW-processable blend was confirmed through a cell viability study, which found a high degree of cytocompatibility.

9 May 2025 in Acta Biomaterialia
Verified
Journal Article
Open access
BTBrooke Tornifoglio
Brooke Tornifoglio
CHC. Hughes
C. Hughes
FDF. Digeronimo
F. Digeronimo
YGYasmine Guendouz
Yasmine Guendouz
RJRobert Daniel Johnston
Robert Daniel Johnston
CLCaitriona Lally
Caitriona Lally
Microstructural imaging enables researchers to visualise changes in the arterial wall, allowing for (i) a deeper understanding of the role of specific components in arterial mechanics, (ii) the observation of cellular responses, (iii) insights into pathological alterations in tissue microstructure, and/or (iv) advancements in tissue engineering aimed at replicating healthy native tissue. In this prospective review, we present various imaging modalities spanning from ex vivo to in vivo applications within arterial tissue. The pros, cons, and sensitivities of these modalities are highlighted. By consolidating the latest advancements in microstructural imaging of arterial tissue, the authors aim for this paper to serve as a guide for researchers designing experiments at various stages. Furthermore, the integration of non-invasive, non-destructive imaging techniques into studies provides an additional layer of microstructural information, enhancing scientific findings, improving our understanding of disease, and potentially enabling earlier or more effective diagnostic capabilities. STATEMENT OF SIGNIFICANCE: Microstructural imaging enables researchers to visualise changes in the arterial wall, allowing for (i) a deeper understanding of the role of specific components in arterial mechanics, (ii) the observation of cellular responses, (iii) insights into pathological alterations in tissue microstructure, and/or (iv) advancements in tissue engineering aimed at replicating healthy native tissue. By consolidating the latest advancements in microstructural imaging of arterial tissue, the authors aim for this paper to serve as a guide for researchers designing experiments at various stages. Furthermore, the integration of non-invasive, non-destructive imaging techniques into studies provides an additional layer of microstructural information, enhancing scientific findings, improving our understanding of disease, and potentially enabling earlier or more effective diagnostic capabilities.

28 March 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ASAlan J. Stone
Alan J. Stone
BTBrooke Tornifoglio
Brooke Tornifoglio
FDFrancesco Digeronimo
Francesco Digeronimo
KSKarin Shmueli
Karin Shmueli
CLCaitriona Lally
Caitriona Lally
Purpose: The aim is to establish the relationship between carotid susceptibility and microstructural components in diseased carotid arteries. Methods: Excised cadaveric carotid arteries ( n = 5) were scanned using high‐resolution QSM at 7 Tesla. After ex vivo imaging, all samples were brought to histology and stained for elastin, collagen, cells, and calcium. An image registration pipeline was used in combination with semi‐quantitative, regional histology analysis to evaluate relationships between MRI and microstructural components. Results: Weak, non‐significant ( p > 0.05) correlations were found between all components and regional magnitude and R 2 * measurements. A significant, moderate negative correlation between the elastin fraction and regional magnetic susceptibility, r elastin = −0.63 ( p < 0.0001) was found, as well as a significant, moderate negative correlation between collagen and regional magnetic susceptibility, r collagen = −0.59 ( p < 0.0001). Conclusion: Tissue magnetic susceptibility in diseased human carotid arteries was shown to be significantly correlated with the dominant microstructural components of pathological human cadaver samples—elastin and collagen. Knowing that elastin and collagen are disrupted in vascular disease progression, QSM offers clinically translatable potential for novel disease biomarkers.

8 January 2026 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
NDNele Demeersseman
Nele Demeersseman
DNDavid Nolan
David Nolan
AGAoife Glynn
Aoife Glynn
FDFrancesco Digeronimo
Francesco Digeronimo
YGYasmine Guendouz
Yasmine Guendouz
CLCaitriona Lally
Caitriona Lally
A detailed understanding of cerebral artery biomechanics is essential for advancing cerebrovascular research and neurovascular device development. Yet, despite the clinical relevance of these vessels, high-fidelity experimental data remains extremely limited. As a result, current device development is often informed by data from non-cerebral vessels or animals. To address this gap, this study characterized the mechanical behavior and structural composition of human middle cerebral arteries obtained from six donors. Ring-extension testing was used to quantify elastin- and collagen-dominant region stiffnesses, while histological staining was used to assess elastin, collagen, and smooth muscle cell (SMC) content. Histology revealed that, unlike large elastic arteries, cerebral arteries are dominated by SMCs, contain sparse elastin, and lack a distinct external elastic lamina. Comparative analysis showed that mechanical behavior could not be inferred from composition alone, highlighting the importance of considering tissue integrity and organization when assessing structure. To explore clinically relevant differences, samples were grouped by cardiovascular disease (CVD) status and arterial branch type (M1 vs. M2). CVD-affected arteries exhibited significantly higher elastin-dominant region stiffness and reduced medial SMC content (p < 0.05). M2 branches showed significantly lower collagen-dominant region stiffness, internal elastic lamina fraction, and adventitial collagen content compared to M1 branches (p < 0.05). These findings highlight the structural and mechanical heterogeneity of human cerebral arteries and suggest that neurovascular device design and deployment strategies might benefit from considering both disease state and anatomical location. By jointly evaluating mechanics and composition, this study provides a foundational dataset to guide future cerebrovascular research and device development.

12 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
FDFrancesco Digeronimo
Francesco Digeronimo
RJRobert Daniel Johnston
Robert Daniel Johnston
BTBrooke Tornifoglio
Brooke Tornifoglio
GKGreet Kerckhofs
Greet Kerckhofs
CLCatriona Lally
Catriona Lally
Visualising and quantifying vascular 3D microstructure are essential for linking it to mechanics and disease. This study evaluated Phospho-Tungstic Acid (PTA) and 1:2 Hafnium-substituted Wells Dawson Polyoxometalate (1:2 Hf-POM) as Contrast-Enhancing Staining Agents (CESAs) for X-ray based 3D Histology (X3DH) using Contrast-Enhanced Micro-focus Computed Tomography (CECT), as alternatives to classical 2D histology for visualising and quantifying collagen and elastin.Native and enzymatically digested porcine carotid artery segments, with varying elastin and collagen content, were CESA-stained and μCT-imaged to generate X3DH data, used to calculate Elastin-Stained Volume Fraction (E-SVF). Equivalent CESA-stained and unstained sections underwent Verhoeff’s (VH), Picrosirius Red (PR), and Haematoxylin–Eosin (H&E) histology to measure Elastin-Stained Area Fraction (E-SAF), Collagen-SAF (C-SAF), and cell density. X3DH results were compared with histology to evaluate correspondence and staining effects. Both CESAs produced strong signal colocalisation with elastic lamellae and weaker staining in the remaining ECM.E-SVF for both CESAs correlated strongly with E-SAF, but E-SVF values were about two times lower than E-SAF (r2PTA=0.86, p<0.0001, slopePTA=0.42 | r21:2-Hf-POM=0.86, p<0.0001, slope1:2-Hf-POM=0.49). This highlights CECT as a non-destructive, accurate method for quantifying vascular microstructure with fewer artefacts than classical 2D histology. VH and PR staining were visually and quantitatively (±10% E-SAF and C-SAF equivalence) unaffected by CESA-staining. PTA-staining with cryopreservation caused loss of nucleic contrast, while 1:2 Hf-POM influenced ECM haematoxylin uptake, reducing nuclei visualisation and cell count accuracy in H&E histology. Both CESAs bind non-specifically but preferentially to elastin, enabling reliable quantification. However, vascular collagen remains difficult to visualise as ECM is non-specifically stained.