Nele Demeersseman

Nele Demeersseman

Auto-generated profile, based on publicly available information

Nele Demeersseman

Biomechanics Section, KU Leuven, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2026 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
NDNele Demeersseman
Nele Demeersseman
DNDavid Nolan
David Nolan
AGAoife Glynn
Aoife Glynn
FDFrancesco Digeronimo
Francesco Digeronimo
YGYasmine Guendouz
Yasmine Guendouz
CLCaitriona Lally
Caitriona Lally
A detailed understanding of cerebral artery biomechanics is essential for advancing cerebrovascular research and neurovascular device development. Yet, despite the clinical relevance of these vessels, high-fidelity experimental data remains extremely limited. As a result, current device development is often informed by data from non-cerebral vessels or animals. To address this gap, this study characterized the mechanical behavior and structural composition of human middle cerebral arteries obtained from six donors. Ring-extension testing was used to quantify elastin- and collagen-dominant region stiffnesses, while histological staining was used to assess elastin, collagen, and smooth muscle cell (SMC) content. Histology revealed that, unlike large elastic arteries, cerebral arteries are dominated by SMCs, contain sparse elastin, and lack a distinct external elastic lamina. Comparative analysis showed that mechanical behavior could not be inferred from composition alone, highlighting the importance of considering tissue integrity and organization when assessing structure. To explore clinically relevant differences, samples were grouped by cardiovascular disease (CVD) status and arterial branch type (M1 vs. M2). CVD-affected arteries exhibited significantly higher elastin-dominant region stiffness and reduced medial SMC content (p < 0.05). M2 branches showed significantly lower collagen-dominant region stiffness, internal elastic lamina fraction, and adventitial collagen content compared to M1 branches (p < 0.05). These findings highlight the structural and mechanical heterogeneity of human cerebral arteries and suggest that neurovascular device design and deployment strategies might benefit from considering both disease state and anatomical location. By jointly evaluating mechanics and composition, this study provides a foundational dataset to guide future cerebrovascular research and device development.

14 October 2024 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
NDNele Demeersseman
Nele Demeersseman
MRMaria Rocchi
Maria Rocchi
HFHeleen Fehervary
Heleen Fehervary
GCGuillermo Fernández Collazo
Guillermo Fernández Collazo
BMBart Meyns
Bart Meyns
NFNele Famaey
Nele Famaey

22 July 2025 in bioRxiv
Verified
Preprint
Open access
TVThibault Vervenne
Thibault Vervenne
NVNic Vermeeren
Nic Vermeeren
NDNele Demeersseman
Nele Demeersseman
HFHeleen Fehervary
Heleen Fehervary
MPMathias Peirlinck
Mathias Peirlinck
NFNele Famaey
Nele Famaey
Understanding the physiological condition of the vascular system is critical to explain, treat, and manage vascular disease. Numerous experimental and computational studies characterize the mechanical behavior of arterial tissue under controlled laboratory conditions. However, translating this knowledge into physiologically realistic conditions remains challenging. Key difficulties include selecting suitable and relevant test methods, minimizing uncertainty, and ensuring robust model validation. We present a novel integrative approach to translate laboratory experiments on arterial samples into clinically relevant pressure–diameter behavior. We perform controlled planar-biaxial tests on carotid arteries under three stretch ratios and generate axial and circumferential stress–stretch data to calibrate a fiber-reinforced soft tissue model. Using an analytical thick-walled cylindrical model, we predict subject-specific pressure–diameter behavior, informed by arterial prestretches from ring opening experiments. We systematically compare predictions against extension-inflation experiments on tubes from the same artery by applying controlled pairs of axial stretch and inner pressure, while recording outer diameter. We quantify prediction error in absolute and relative stretch regimes and evaluate the importance of the load-free reference dimensions. Results show how planar-biaxial tests probe different stretch regimes compared to extension-inflation deformations, leading to extrapolation of model predictions. We demonstrate how the constitutive material parameters can be fitted to different biomechanical loading conditions and assess the sensitivity of the simulations to axial stretch and circumferential prestretch. Only when key model parameters are accurately captured and their uncertainty propagated, planar-biaxial stress–stretch data can reliably predict arterial pressure–diameter behavior.

16 September 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
NDNele Demeersseman
Nele Demeersseman
LMLauranne Maes
Lauranne Maes
BDBart Depreitere
Bart Depreitere
NFNele Famaey
Nele Famaey
Background: Cerebral autoregulation stabilizes cerebral blood flow over a range of cerebral perfusion pressures, but the precise shape of the pressure-flow relationship remains debated. The classical triphasic pressure-flow relationship was recently challenged by experiments demonstrating a quadriphasic response, hypothesized to arise from vessel-size-dependent pressure-diameter responses. We tested this hypothesis and investigated whether these size-dependent responses originate from heterogeneity in smooth muscle cell (SMC) abundance, SMC behavior, or neither. Methods: We developed a computational multi-scale physics-based model of cerebral autoregulation linking SMC activity to vessel-scale diameter regulation and organ-scale blood flow. Four scenarios were evaluated: passive vessels, homogeneous SMC abundance and behavior, heterogeneous SMC abundance, and heterogeneous SMC behavior. Predicted pressure-diameter responses and pressure-flow relationships were compared across scenarios and against experimental observations. Results: In contrast to passive vessels, homogeneous SMC activation produced partial flow stabilization, highlighting the key role of SMCs in autoregulation. However, only heterogeneous SMC behavior reproduced the experimentally observed vessel-size-dependent trends in pressure-diameter responses. This scenario also showed the best agreement with the experimental organ-scale pressure-flow relationship (R-squared = 0.93, nRMSE = 5.96%). Conclusion: The model suggests that vessel-size-dependent SMC behavior underlies vessel-size-dependent pressure-diameter responses and shapes the relationship between cerebral perfusion pressure and cerebral blood flow.